This is a
To include the SSP 301 onto a network, put the controller into inclusion mode. Now press and hold the button on SSP 301 for 4 to 7 seconds thenrelease. The network status LED will start flashing (twice per second) on successful start of inclusion process. On successful inclusion the LED will turn off.
The Secure SSP 301 is a switch and repeater that forms part of a Z-Wave Plus home automation network. The SSP 301 is a mains powered device with ANZ plug type,that will switch (power On/Off) a connected appliance either by the Z-Wave network or manually by pressing its integrated button.The SSP 301 acts as a repeater in a Z-Wave network by helping messages from other devices reachtheredestinations.
Reset to factory default | Please use this procedure only when the primary controller is missing or otherwise inoperable, Power cycle the device, press and hold the buttonfor 7-11 seconds within the 60 seconds of power cycle to put the device in factory default. It reset all configuration and association to factory default. It also removes the device from Z-Wave network. |
Inclusion | To include the SSP 301 onto a network, put the controller into inclusion mode. Now press and hold the button on SSP 301 for 4 to 7 seconds thenrelease. The network status LED will start flashing (twice per second) on successful start of inclusion process. On successful inclusion the LED will turn off. |
Exclusion | To exclude the SSP 301 from a network, put the controller into exclusion mode. Now press and hold the button on SSP 301 for 4 to 7 seconds thenrelease. After successful exclusion the network status LED will startflashing once per second, and the device will reset to factory default. |
NIF | XXXNIF |
Wakeup | NA |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 4 | Z-Wave Plus Lifeline |
This configuration enable the switch status reporting, when switch status changed for OFF to ON or ON to OFF. Size: 1 Byte, Default Value: 1
Setting | Description |
---|
This configuration enable the switch status reporting based on the time interval configured. Note: Controllers may only allow configuring signed values. In order to set values in the range 32768 65520, the value sent in the application shall be equal to desired value minus 65520. For example, to set time intervalto 36000 seconds it may be needed to set a value 3600065536=29536. Size: 2 Byte, Default Value: 0
Setting | Description |
---|
This configuration is used to change the relay LED status when relay is open/close and also enable to whether to retain the last relay status over power cycle.0 - Relay status will not be retain over power cycle, and Relay status LED will lit when relay ON and relay status LED will off when relay OFF. 1 - Relay status will be retain over power cycle, and Relay status LED will lit when relay ON and relay status LED will off when relay OFF.2 - Relay status will not be retain over power cycle, and Relay status LED will off when relay ON and relay status LED will lit when relay OFF.3 - Relay status will be retain over power cycle, and Relay status LED will off when relay ON and relay status LED will lit when relay OFF. Size: 1 Byte, Default Value: 0
Setting | Description |
---|
Hardware Platform | ZM5202 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | 02 |
Z-Wave Version | 6.51.02 |
Certification ID | ZC10-15020010 |
Z-Wave Product Id | 0x0059.0x000E.0x0002 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |