Quickstart

This is a On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
To include the SSP 301 onto a network, put the controller into inclusion mode. Now press and hold the button on SSP 301 for 4 to 7 seconds thenrelease. The network status LED will start flashing (twice per second) on successful start of inclusion process. On successful inclusion the LED will turn off.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The Secure SSP 301 is a switch and repeater that forms part of a Z-Wave Plus home automation network. The SSP 301 is a mains powered device with EU plug type,that will switch (power On/Off) a connected appliance either by the Z-Wave network or manually by pressing its integrated button.The SSP 301 acts as a repeater in a Z-Wave network by helping messages from other devices reachtheredestinations.

Reset to factory default Please use this procedure only when the primary controller is missing or otherwise inoperable, Power cycle the device, press and hold the buttonfor 7-11 seconds within the 60 seconds of power cycle to put the device in factory default. It reset all configuration and association to factory default. It also removes the device from Z-Wave network.
Inclusion To include the SSP 301 onto a network, put the controller into inclusion mode. Now press and hold the button on SSP 301 for 4 to 7 seconds thenrelease. The network status LED will start flashing (twice per second) on successful start of inclusion process. On successful inclusion the LED will turn off.
Exclusion To exclude the SSP 301 from a network, put the controller into exclusion mode. Now press and hold the button on SSP 301 for 4 to 7 seconds thenrelease. After successful exclusion the network status LED will startflashing once per second, and the device will reset to factory default.
NIF XXXNIF
Wakeup NA
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 4 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 1: Delta Based Switch Status Reporting

This configuration enable the switch status reporting, when switch status changed for OFF to ON or ON to OFF.
Size: 1 Byte, Default Value: 1

Setting Description

Parameter 2: Time interval based Switch Status Reporting

This configuration enable the switch status reporting based on the time interval configured. Note: Controllers may only allow configuring signed values. In order to set values in the range 32768 65520, the value sent in the application shall be equal to desired value minus 65520. For example, to set time intervalto 36000 seconds it may be needed to set a value 3600065536=29536.
Size: 2 Byte, Default Value: 0

Setting Description

Parameter 3: Relay and LED configuration

This configuration is used to change the relay LED status when relay is open/close and also enable to whether to retain the last relay status over power cycle.0 - Relay status will not be retain over power cycle, and Relay status LED will lit when relay ON and relay status LED will off when relay OFF. 1 - Relay status will be retain over power cycle, and Relay status LED will lit when relay ON and relay status LED will off when relay OFF.2 - Relay status will not be retain over power cycle, and Relay status LED will off when relay ON and relay status LED will lit when relay OFF.3 - Relay status will be retain over power cycle, and Relay status LED will off when relay ON and relay status LED will lit when relay OFF.
Size: 1 Byte, Default Value: 0

Setting Description

Technical Data

Hardware Platform ZM5202
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version 01
Z-Wave Version 6.51.02
Certification ID ZC10-15020011
Z-Wave Product Id 0x0059.0x000E.0x0001
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)On/Off Power Switch