Quickstart

This is a Thermostat - HVAC for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Go to Menu screen, and press INCLUDE icon.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The Z-Wave enabled CT32 thermostat is a compact, easy-to-use thermostat that is packed with functionality. The CT32 has a responsive touchscreen interface, easy-to-read backlight display, and 7-day programmability. It features a system lock to avoid unintentional changes for maximum efficiency, a filter change indicator to keep your HVAC system running efficiently, wide temperature operation range, and room temperature calibration for precise control.

Reset to factory default In Main menu, put thermostat in OFF mode. Press and hold center digits.Use the reset procedure only when the primary controller is missing or inoperable.
Inclusion Go to Menu screen, and press INCLUDE icon.
Exclusion Go to Menu screen, and press EXCLUDE icon.
NIF XXXNIF
Wakeup When included into a Z-Wave network on battery power, this device is a FLiRS device. The Thermostat will wake up for communication when it receives a valid Z-Wave beam.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 2 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 1: Temperature Reporting Threshold

The Temperature Reporting Threshold Configuration Set Command sets the reporting threshold for changes in the ambient temperature as detected by the thermostat.
Size: 1 Byte, Default Value: 2

Setting Description

Parameter 10: Temperature Reporting Filter

The Temperature Reporting Filter configuration command sets upper and lower bounds of the ambient temperature reporting.
Size: 2 Byte, Default Value: 0

Setting Description
0 - 31868 Byte 1: 0 -124F (lower bound), Byte 2: 0-124F (upper bound)

Parameter 11: Simple UI Mode

Enables or disables Simple UI mode on thermostat via RadioBus Read/Set UI command.
Size: 1 Byte, Default Value: 1

Setting Description
0 - 1 0 = Normal Mode, 1 = Simple Mode

Parameter 12: Multicast

This parameter controls how the thermostat sends unsolicited reports.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 0 = Disabled, 1 = Enabled

Parameter 2: HVAC Settings

The HVAC Settings Configuration Report Command returns the current HVAC configuration. The HVAC settings must be fixed before the thermostat is joined to the Z-Wave network.
Size: 4 Byte, Default Value: 0

Setting Description
1 - 2147483647 Byte 1: normal (1) or heat pump (2). Byte 2, Bits 7-4: Gas (1) or Electric (2). Byte 2, Bits 3-0: # of Auxiliary Stages. Byte 3: # of Heat Pump Stages. Byte 4: # of Cool Stages.

Parameter 3: Utility Lock

The Utility Lock Configuration Set command enables or disables the utility lock. If the utility lock is enabled, the setpoint cannot be modified directly via the thermostat screen.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 255 0 = Disabled, 1 - 255 = Enabled

Parameter 4: C-Wire/Battery

The C-Wire / Battery Status Configuration Report Command returns the status of the thermostat power source. The power state is fixed when the thermostat joins the network.
Size: 1 Byte, Default Value: 0

Setting Description
1 - 2 1=C-Wire, 2=Battery

Parameter 5: Humidity Reporting Threshold

The Humidity Threshold Configuration Set Command sets the reporting threshold for changes in the relative humidity as detected by the thermostat.
Size: 1 Byte, Default Value: 5

Setting Description
0 - 3 0 = Disabled, 1 = 3% RH, 2 = 5% RH, 3 = 10% RH

Parameter 6: Auxiliary/Emergency Mode

The Auxiliary/Emergency configuration command enables or disables auxiliary / emergency heating in the thermostat.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 0 = Disabled, 1 = Enabled

Parameter 7: Thermostat Swing Temperature

The Thermostat Swing Temperature configuration command sets swing temperature on the thermostat.
Size: 1 Byte, Default Value: 2

Setting Description
1 - 8 1 = 0.5F, 2 = 1.0F, 3 = 1.5F, 4 = 2.0F, 5 = 2.5F, 6 = 3.0F, 7 = 3.5F, 8 = 4.0F

Parameter 8: Thermostat Differential Temperature

The Thermostat Differential Temperature configuration command sets the differential temperature for multi-stage HVAC systems.
Size: 2 Byte, Default Value: 4

Setting Description
0 - 1 0x00 (Heat) or Cool (0x01)
2 - 6 The thermostat differential temperature is in units of 0.5 degrees Fahrenheit.

Parameter 9: Thermostat Recovery Mode

The Thermostat Recovery Mode configuration command sets the HVAC recovery mode type. The recovery mode determines when additional HVAC stages are turned off as the ambient temperature returns to the target temperature.
Size: 1 Byte, Default Value: 2

Setting Description
1 - 2 1 = Fast, 2 = Economy

Technical Data

Hardware Platform ZM5202
Device Type Thermostat - HVAC
Network Operation Always On Slave
Firmware Version HW: 250
Z-Wave Version 6.51.02
Certification ID ZC10-15060004
Z-Wave Product Id 0x0098.0x2002.0x0100
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoThermostat - HVAC