Quickstart

This is a Notification Sensor for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action Button that you can find in the back of the product.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Aeon Labs Door/ Window Sensor Gen5 is a smart Z-Wave sensor that can detect the status of door/window's open/close in real time. Its a security Z-Wave device that supports security encryption. Also it supports the Over the Air Firmware Updating that allows you wirelessly update its firmware if needs. It can be included and operated in any Z-Wave network with other Z-Wave certified devices from manufacturers and/or other applications.

Reset to factory default Press the Action Button once that you can find in back of the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable.
Inclusion Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action Button that you can find in the back of the product.
Exclusion Turn the primary controller of Z-Wave network into exclusion mode, short press the products Action Button that you can find in back of the product.
NIF XXXNIF
Wakeup Press the Action Button once, which will trigger sending out the Wake up notification command, press and hold the Action Button for 3 seconds, which will toggle on/off the Sensor be waked up for 10 minutes.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Group 1 is assigned to the Lifeline association group and every device has 5 nodes to associate. The sensor binary report, basic set or notification report command can be sent in this group when the Sensor is triggered.

Configuration Parameters

Parameter 1: Which value of the Sensor Binary Report will be sent when the door is Opened/Closed.

To set which value of the Sensor Binary Report will be sent when the door is Opened/Closed.
Size: 1 Byte, Default Value: 1

Setting Description
0 Sensor Binary Report =0xFF when the door is Closed, Sensor Binary Report= 0x00 when the door is opened.
1 Sensor Binary Report= 0x00 when the door is closed, Sensor Binary Report=0xFF when the door is opened.

Parameter 111: Set the interval time of battery report.

Set the interval time of battery report.Note:1, if the value is less than 10, the time unit is second.If the value is more than 10, the time unit is 4 minutes, which means if the value is more than 10 and less than 240, the interval time is 4 minutes. If the value is more than 240 and less than 480, the interval is 8 minutes.2, if the current battery report falls below the low battery value (configurable parameter 39), it will send battery report=0xFF.
Size: 4 Byte, Default Value: 0

Setting Description
0 - 2147483647 The range of interval can be set to 0 to 2147483647.

Parameter 121: To configure which sensor report will be sent when the Sensor is triggered On/Off.

To configure which sensor report will be sent when the Sensor is triggered On/Off.
Size: 4 Byte, Default Value: 256

Setting Description
16 Basic Set CC is selected.
256 Sensor Binary Report CC is selected.
272 Basic Set CC and Sensor Binary Report CC are selected.

Parameter 2: Enable/disable wake up 10 minutes when re-power on the Sensor.

Enable/disable wake up 10 minutes when re-power on the Sensor.
Size: 1 Byte, Default Value: 1

Setting Description
0 Disable.
1 Enable.

Parameter 255: Reset the Sensor.

Reset the Sensor.
Size: 4 Byte, Default Value: 0

Setting Description
0 Reset to default settings.
1431655765 Reset to default settings and excluded from the network.

Parameter 3: Which value of the Basic Set will be sent when the door is Opened/Closed.

To set which value of the Basic Set will be sent when the door is Opened/Closed.
Size: 1 Byte, Default Value: 1

Setting Description
0 Basic Set=0xFF when the door is Closed, Basic Set=0x00 when the door is opened.
1 Basic Set 0x00 when the door is Closed, Basic Set= 0xFF when the door is opened.

Parameter 39: Set the low battery value.

Set the low battery value.(10% to 50%).
Size: 1 Byte, Default Value: 10

Setting Description
10 - 50 The range of low battery value can be set to 10% to 50%.

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 78 FW: 1.05
Z-Wave Version 6.51.06
Certification ID ZC10-15110015
Z-Wave Product Id 0x0086.0x0102.0x0078
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoNotification Sensor