This is a
When a PSMZ0001 that is not associated to a Z-Wave Network, is inserted into the mains outlet, it will flash once red followed by 2 green flashes followed by steady red flashing. The PSMZ0001 can now be added to (=inclusion) or removed from (=exclusion) a Z-Wave network:1) start inclusion/exclusion on the primary controller2) hold the touch button until the ledshows green light3) release the touch buttonThe PSMZ0001 will confirm successful addition to the network by 5 green flashes.
The wireless relay switch PSMZ0001 allows you to remotely control electrical appliances. It features a metering function to measure the power consumption and the accumulated energy usage of connected equipment. The built-in metering unit is of high quality: it calculates the true-power and also works for small loads from 1W upwards. This feature is important to have a correct measurement value also for electronic loads like led lamps. The PSMZ0001 has a built-in safety features that will switch-off the output in case of too high temperature or overload.Additionally the PSMZ0001 has a feature to switch the load on at zero voltage and switch the load off at zero current. This leads to a very high number of possible switching cycles also for difficult loads like led-lamps or motors, e.g. pumps.
Reset to factory default | Please use this procedure only if the primary controller is missing or inoperable:The device can be put into factory default state manually by the following procedure:1) hold the touch-button until the led shows red light2) release the touch-button and hold the touch-button again until the led starts to flash greenThe PSMZ0001 confirms the successful completion of the factory reset procedure by steady red flashing. |
Inclusion | When a PSMZ0001 that is not associated to a Z-Wave Network, is inserted into the mains outlet, it will flash once red followed by 2 green flashes followed by steady red flashing. The PSMZ0001 can now be added to (=inclusion) or removed from (=exclusion) a Z-Wave network:1) start inclusion/exclusion on the primary controller2) hold the touch button until the ledshows green light3) release the touch buttonThe PSMZ0001 will confirm successful addition to the network by 5 green flashes. |
Exclusion | When a PSMZ0001 that is not associated to a Z-Wave network is inserted into the mains outlet, it will flash once red followed by 2 green flashes followed by steady red flashing. The PSMZ0001 can now be added to (=inclusion) or removed from (=exclusion) a Z-Wave network:1) start inclusion/exclusion on the primary controller2) hold the touch button until the ledshows green light3) release the touch buttonThe PSMZ0001will confirm successful removal/exclusion by steady red flashing. At the time of exclusion the device is factory reset. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline / Group 1(1)Sends COMMAND_CLASS_BASIC, BASIC_REPORT after every change of the output state (on/off). (2)Sends COMMAND_CLASS_METER_V2, METER_REPORT_V2 after every change of the measured energy or power value or after a timeout if the values stay unchanged. during If the energy or power value didnt change for a certain time. |
2 | 5 | Group2:Sends COMMAND_CLASS_BASIC, BASIC_REPORT every time the load is connected. |
If LocalControlOn is set (factory default state) the PMSZ001s output can be switched manually by the touch button. If LocalControlOff is set, the PMSZ0001s output can only be switched through Z-Wave telegrams. In both modes the operational state of the mechanical switch is reported to association group 2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Local Control On |
1 | Local Control Off |
Hardware Platform | ZM5101 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 255 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-15120009 |
Z-Wave Product Id | 0x0248.0x0003.0x0001 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |