Quickstart

This is a Whole Home Meter - Simple for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. 2. Pressing Include button three times within 2 seconds will enter inclusion mode.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

This dual meter module is a transceiver which is a Z-WaveTM enabled device and is fully compatible with any Z-WaveTM enabled network. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. And it can act as repeaters within the network regardless of vendor to increase reliability of the network.Mini size design let the module can easily hide itself into the electricity distribution box and that will be good for the house decoration. This dual meter module is able to detect Instant power wattage (13800W/230Vac)(60 Amperes) of connected light or appliances.

Reset to factory default Use this procedure only in the event that the primary controller is lost or otherwise inoperable.1. Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode.2. Within 1 second, press Include button again for 5 seconds. 3. IDs are excluded.
Inclusion 1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. 2. Pressing Include button three times within 2 seconds will enter inclusion mode.
Exclusion 1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer. 2. Pressing Include button three times within 2 seconds will enter exclusion mode. 3. Node ID has been excluded.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus LifelineFor group 1, the Switch will report (1) Instant Power Consumption (Watt) read from CT1 (2) Accumulated Power Consumption (KWh) read from CT1.
2 1 For group 2, the Switch will report (1) Instant Power Consumption (Watt) read from CT2 (2) Accumulated Power Consumption (KWh) read from CT2.
3 1 For group 3, the Switch will report (1) The sum of instant Power Consumption (Watt) read from CT1 and CT2 (2) The sum of accumulated Power Consumption (KWh) read from CT1 and CT2.

Configuration Parameters

Parameter 1: Watt Meter Report Period

If the setting is configured for 1hour (set value =720), the PAB01 will report its instant power consumption every 1 hour to the node of correspond Group. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr).
Size: 2 Byte, Default Value: 720

Setting Description
1 - 32767 5*720s=3600s=1 hour

Parameter 2: KWH Meter Report Period

If the setting is configured for 1hour (set value =720), the PAB01 will report its Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond Group. The maximum interval to report its Accumulated Power Consumption (KW/h) is 45 hours (5s*32767/3600=45hr).
Size: 2 Byte, Default Value: 720

Setting Description
1 - 32767 5*720s=3600s=1 hour

Parameter 3: Selected Endpoint

If Controller can't use Multi_Channel command class to access the endpoint of PAB01, you may configure the endpoint value to react the Basic Command Class Binary Switch Command Class or Meter Command Class V3.
Size: 1 Byte, Default Value: 3

Setting Description
1 1CT1
2 2CT2
3 3CT1 and CT2

Parameter 4: Threshold of Current for Load Caution

This is a warning when the current of load over the preset threshold value, If the setting value is 6000, when the load wattage of CT1 or CT2 over 60A, PAB01 will send current Meter Report command to the node of correspond Group.
Size: 2 Byte, Default Value: 6000

Setting Description
10 - 6000 6000*0.01A=60A

Parameter 5: Threshold of KWh for Load Caution

This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of CT1 or CT2 over this value, PAB01 will send KWh Meter Report command to the node of correspond Guoup, minum value is 1KWh and default value is 10000 kWh.
Size: 2 Byte, Default Value: 10000

Setting Description
1 - 10000 10000*1KWH=10000KWH

Parameter 6: Existence of Endpoint3

Multi-Channel Command is a good way to control relay1 and relay2 of PAB01 individually. The endpoint3 of PAB01 is related to both relay1 and relay2. In some condition it becomes redundant in Multi-Channel Command Class. When the Existence of Endpoint3 is set as 2, the endpoint3 will be disabled. The default value is 1. Endpoint1 and Endpoint2 are fixed, only Endpoint3 is dynamic.
Size: 1 Byte, Default Value: 1

Setting Description
1 1 : Endpoint3 exist
2 2 : No Endpoint3

Technical Data

Hardware Platform SD3502
Device Type Whole Home Meter - Simple
Network Operation Always On Slave
Firmware Version 01
Z-Wave Version 6.51.06
Certification ID ZC10-16010004
Z-Wave Product Id 0x013C.0x0006.0x001A
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Whole Home Meter - Simple