1.Put your Z-Wave controller into inclusion mode.2.Plug the SmatPlug into the power outlet.3.Press and hold on/off button about 5 seconds.4.Orange LED will be flashing about 2 seconds, then inclusion process will be start.5.Wait until inclusion will be done.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Smart-Plug plugs in between any appliance and the AC outlet. It measures its power consumption & sends that information to your smartphone. It can also control power source connected with appliance manually and remotely using smartphone.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.1.Plug the SmatPlug into the power outlet.2.Press and hold on/off button about 10 seconds.3.Orange LED will be flashing about 2 seconds, then factory reset process will be start.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
First 3 Bytes : Standby Power Setting Value Last 1 Byte : Standby Power Enable/Disable Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | standby power disable |
256001 | standby power enable with 10.00 watt |
Periodic Measurement Value Transmission Enable/Disable Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Periodic Measurement Value Transmission Disable |
1 | Periodic Measurement Value Transmission Enable |
Power Accumulation Stop / Start Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Power Accumulation Stop |
1 | Power Accumulation Start |
Connected Device Use / Not Use Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Connected Device Not Use |
1 | Connected Device Use |
Periodic Measurement Value Transmission IntervalMinimum time interval : 10minutes Size: 1 Byte, Default Value: 6
Setting | Description |
---|---|
1 - 144 | 1 = 10min, 144 = 1440 min |
Hardware Platform | ZM5202 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 27.10 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-16055090 |
Z-Wave Product Id | 0x0247.0x0042.0x0001 |
Switch Type | Toggle |
Firmware Updatable | Updatable by Manufacturer |
Supported Meter Type | Electric Energy |
Frequency | XXfrequency |