Quickstart

This is a On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Set the Z-Wave network main controller into learning mode. Short press the Z-button, the LED will keep turning on or off, which indicates the inclusion is successful.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Smart Plug is a Z-Wave Switch plugin module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool. It can report wattage consumption or kWh energy usage.Smart Plug is also a security Z-Wave device and supports the Over The Air (OTA) feature for the products firmware upgrade.

Reset to factory default Press and hold the Z-button for more than 20 seconds, the LED will blink faster and faster when the button is pressed. If holding time more than 20seconds, the LED indicator will be on for 3 seconds then it blinking slowly, which indicates the reseting is successful. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable.
Inclusion Set the Z-Wave network main controller into learning mode. Short press the Z-button, the LED will keep turning on or off, which indicates the inclusion is successful.
Exclusion Set the Z-Wave network main controller into remove mode. Triple click the Z-button, the LED will blink slowly, which indicates the inclusion is successful.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Group 1 is assigned to the Lifeline association group and every device has 5 nodes to associate. When the switch is turned on or off , the switch will send a basic report of its status to the nodes in association group 1. To change what kind of signal is sent to the nodes in group 1, please see the detailed description of configuration parameter 24.

Configuration Parameters

Parameter 151: Threshold of change in wattage

The value here represents minimum change in wattage (in terms of wattage) for sending a METER REPORT (for wattage) to the associated device (Group Lifeline).
Size: 2 Byte, Default Value: 50

Setting Description
0 The function is disabled
1 - 65535 The minimum change value in wattage for sending a meter report to the associated device

Parameter 152: Threshold of change in wattage percentage

The value here represents minimum change in wattage percent (in terms of percentage) for sending a METER REPORT (for wattage) to the associated device (Group Lifeline).
Size: 1 Byte, Default Value: 10

Setting Description
0 The function is disabled.
1 - 255 The minimum change value in wattage percent for sending a meter report to the associated device

Parameter 171: Intervals of sending METER REPORT (for wattage)

The time interval of sending Meter Report (for wattage) to the associated device (Group Lifeline).
Size: 4 Byte, Default Value: 30

Setting Description
5 - 2678400 The time for sending a meter report
0 The function is disabled.

Parameter 172: Intervals of sending METER REPORT (for kWh)

The time interval of sending Meter Report (for kWh) to the associated device (Group Lifeline).
Size: 4 Byte, Default Value: 300

Setting Description
5 - 2678400 The time for sending a meter report
0 The function is disabled.

Parameter 173: Intervals of sending METER REPORT (for voltage).

The time interval of sending Meter Report (for voltage) to the associated device (Group Lifeline).
Size: 4 Byte, Default Value: 0

Setting Description
5 - 2678400 The time for sending a meter report
0 The function is disabled

Parameter 174: Intervals of sending METER REPORT (for current).

The time interval of sending Meter Report (for voltage) to the associated device (Group Lifeline).
Size: 4 Byte, Default Value: 0

Setting Description
0 The function is disabled
5 - 2678400 The time for sending a meter report

Parameter 20: Overcurrent protection

Smart Plug keep detecting the load current, once the current exceeds 16.5A for more than 5 seconds, smart plug's load will turn off.
Size: 1 Byte, Default Value: 1

Setting Description
0 The function is disabled
1 The function is enabled

Parameter 21: Setting Smart Plugs load status after re-power on

Define Smart Plugs load status after re-power on.
Size: 1 Byte, Default Value: 0

Setting Description
0 last status
1 Always on
2 Always off

Parameter 24: Notification when Load status changed

Smart Plug can send notifications to association device (Group Lifeline) when state of smart plugs load changed.
Size: 1 Byte, Default Value: 1

Setting Description
0 The function is disabled.
1 Send BASIC REPORT
2 Send BASIC REPORT only when Load condition is changed not by Z-WAVE Command, such as short pressing.

Parameter 27: Indicator modes

After Smart Plug being included into a Z-Wave network, the LED in the device will indicate the Smart Plugs load status.
Size: 1 Byte, Default Value: 0

Setting Description
0 The LED will follow the status (on/off) of its load
1 When the state of Switchs load changed, The LED will follow the status (on/off) of its load, but the red LED will turn off after 5 seconds if there is no any switch action.

Technical Data

Hardware Platform ZM5202
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.03
Z-Wave Version 6.51.07
Certification ID ZC10-16065124
Z-Wave Product Id 0x0208.0x0101.0x0005
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoOn/Off Power Switch