Set the Z-Wave network main controller into learning mode. Short press the Z-button, the LED will keep turning on or off, which indicates the inclusion is successful.
Smart Plug is a Z-Wave Switch plugin module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool. It can report wattage consumption or kWh energy usage.Smart Plug is also a security Z-Wave device and supports the Over The Air (OTA) feature for the products firmware upgrade.
Reset to factory default | Press and hold the Z-button for more than 20 seconds, the LED will blink faster and faster when the button is pressed. If holding time more than 20seconds, the LED indicator will be on for 3 seconds then it blinking slowly, which indicates the reseting is successful. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. |
Inclusion | Set the Z-Wave network main controller into learning mode. Short press the Z-button, the LED will keep turning on or off, which indicates the inclusion is successful. |
Exclusion | Set the Z-Wave network main controller into remove mode. Triple click the Z-button, the LED will blink slowly, which indicates the inclusion is successful. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Group 1 is assigned to the Lifeline association group and every device has 5 nodes to associate. When the switch is turned on or off , the switch will send a basic report of its status to the nodes in association group 1. To change what kind of signal is sent to the nodes in group 1, please see the detailed description of configuration parameter 24. |
The value here represents minimum change in wattage (in terms of wattage) for sending a METER REPORT (for wattage) to the associated device (Group Lifeline). Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 | The function is disabled |
1 - 65535 | The minimum change value in wattage for sending a meter report to the associated device |
The value here represents minimum change in wattage percent (in terms of percentage) for sending a METER REPORT (for wattage) to the associated device (Group Lifeline). Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | The function is disabled. |
1 - 255 | The minimum change value in wattage percent for sending a meter report to the associated device |
The time interval of sending Meter Report (for wattage) to the associated device (Group Lifeline). Size: 4 Byte, Default Value: 30
Setting | Description |
---|---|
5 - 2678400 | The time for sending a meter report |
0 | The function is disabled. |
The time interval of sending Meter Report (for kWh) to the associated device (Group Lifeline). Size: 4 Byte, Default Value: 300
Setting | Description |
---|---|
5 - 2678400 | The time for sending a meter report |
0 | The function is disabled. |
The time interval of sending Meter Report (for voltage) to the associated device (Group Lifeline). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
5 - 2678400 | The time for sending a meter report |
0 | The function is disabled |
The time interval of sending Meter Report (for voltage) to the associated device (Group Lifeline). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The function is disabled |
5 - 2678400 | The time for sending a meter report |
Smart Plug keep detecting the load current, once the current exceeds 16.5A for more than 5 seconds, smart plug's load will turn off. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | The function is disabled |
1 | The function is enabled |
Define Smart Plugs load status after re-power on. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | last status |
1 | Always on |
2 | Always off |
Smart Plug can send notifications to association device (Group Lifeline) when state of smart plugs load changed. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | The function is disabled. |
1 | Send BASIC REPORT |
2 | Send BASIC REPORT only when Load condition is changed not by Z-WAVE Command, such as short pressing. |
After Smart Plug being included into a Z-Wave network, the LED in the device will indicate the Smart Plugs load status. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The LED will follow the status (on/off) of its load |
1 | When the state of Switchs load changed, The LED will follow the status (on/off) of its load, but the red LED will turn off after 5 seconds if there is no any switch action. |
Hardware Platform | ZM5202 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.03 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-16065124 |
Z-Wave Product Id | 0x0208.0x0101.0x0005 |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |