This is a
Press Fn switch 3 times in a row to include the device to Z-Wave network.
Smart Energy Multi Tap plugs in between any appliance and the AC outlet. It can monitor and control power using your smartphone. It can also control the power source connected with appliance manually and remotely using your smartphone.
Reset to factory default | Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. Press Fn switch over 10~15 sec to initialize connecting network information. |
Inclusion | Press Fn switch 3 times in a row to include the device to Z-Wave network. |
Exclusion | Press Fn switch 3 times in a row again to cancel the inclusion of the device on Z-Wave network. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline Group. |
2 | 5 | Notice button status with switch binary report. |
3 | 5 | Notice AC power status with meter report. |
GRCCSGroup Report Command Class Setup1. CRCGroup report crc16 enable/disable- 0x00 : Group report CRC16 Disable- 0x01 : Group report CRC16 Enable2. MRSSSelect Scale of Meter report- 0x00 : Meter report command scale (kWh)- 0x02 : Meter report command scale (Watt) Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | CRCGroup report crc16 enable/disable |
0 - 2 | MRSSSelect Scale of Meter report |
Interval time setting for (60~65535 second)Report group Size: 4 Byte, Default Value: 720
Setting | Description |
---|---|
60 - 65535 | Interval time setting |
Automatically meter report control (AMRC) is report mode setting of the Meter data. - 00b : Deactivate the meter report - 01b : In case Parameter 91~92 is bigger than setting value, report the event.Report interval is 31 seconds after trigger. - 10b : Automatic report by the set interval in the Parameter 111. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | Deactivate the Meter data report |
0 - 1 | Trigger level event mode |
1 - 0 | Time Interval Mode |
Initialize Configuration parameter Parameter number 2 : Initialize Parameter 2Parameter number 3 : Initialize Parameter 3Parameter number 91 : Initialize Parameter 91Parameter number 92 : Initialize Parameter 92Parameter number 101 : Initialize Parameter 101Parameter number 111 : Initialize Parameter 111Parameter number 255 : Reset to the default full parameter Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
2 - 255 | Initialize Configuration parameter |
Automatically key report control (AKRC) is report mode setting of the Key data. - 00b : Deactivate the button activation report - 01b : Button Activation report Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Deactivate the button activation report |
0 - 1 | Button Activation report |
Group1 Watt Trigger level valueTrigger value setting (0~65535) for Meter report of Parameter2. Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 65535 | Group1 Watt Trigger level value |
Group1 kWh Trigger level valueTrigger value setting (0~65535) for Meter report of Parameter2. Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 65535 | Group1 kWh Trigger level value |
Hardware Platform | ZM5101 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-16075152 |
Z-Wave Product Id | 0x0242.0x0003.0x0014 |
Firmware Updatable | Updatable by Consumer by RF |
Color | White |
Switch Type | Push Button |
Supported Meter Type | Electric Energy |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |