Quickstart
This is a
On/Off Power Switch for XXXQFrequencyName.
To run this device please connect it to your mains power supply.
To add this device to your network execute the following action:
1. Enter your Z-Wave controller into inclusion mode2. Press the socket on/off button three times within 1.5 seconds to be included.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from
Z-Wave Alliance Product
data and may be incomplete. Please refer to the
Manufacturers Manual for more information.
Product Description
This smart energy plug is able to detect current wattage (5-3000W) and overload wattage (3010-3300W) of connected lights or appliances. When detecting overload state, the switch will be disabled and its on/off button will be lockout of which LED will flash quickly. However, unplug and re-connect the switch and it will reset its overload condition to normal status.
Reset to factory default |
1. To reset, press the socket on/off button three times within 1.5 seconds2. then the fourth time, press and hold for seconds until the socket LED is off3. the socket reset successfullyUse the "Reset" procedure only in the event that the network primary controller is missing or otherwise inoperable |
Inclusion |
1. Enter your Z-Wave controller into inclusion mode2. Press the socket on/off button three times within 1.5 seconds to be included. |
Exclusion |
1. Enter your Z-Wave controller into exclusion mode2. Press the socket on/off button three times within 1.5 seconds to be excluded. |
NIF |
XXXNIF |
Wakeup |
XXXWakeupDescription |
Protection |
XXXProtection |
FirmwareUpdate |
XXXFirmwareUpdate |
SetAssociation |
XXXSetAssociation |
Association Groups:
Group Number |
Maximum Nodes |
Description |
1 |
5 |
It can be associated by other devicesProfile: general lifeline( Profile MSB=0, profile LSB=1)Group 1: lifeline |
Technical Data
Hardware Platform |
ZM5202 |
Device Type |
On/Off Power Switch |
Network Operation |
Always On Slave |
Firmware Version |
HW: 1 FW: 2.00 |
Z-Wave Version |
6.51.06 |
Certification ID |
ZC10-16095208 |
Z-Wave Product Id |
0x0118.0x0004.0x0002 |
Supported Meter Type |
Electric Energy |
Color |
White |
Frequency |
XXfrequency |
Maximum transmission power |
XXantenna |