Quickstart
This is a
Notification Sensor for XXXQFrequencyName.
To run this device please make sure the internal battery is fully charged.
To add this device to your network execute the following action:
Z-Wave primary controller into inclusion mode. And press the inclusion/exclusion switch for sending NIF.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from
Z-Wave Alliance Product
data and may be incomplete. Please refer to the
Manufacturers Manual for more information.
Product Description
Door / Window Open. Close monitoring function Case open , Battery level monitoring function LED function OTA
Reset to factory default |
Held 10 seconds the inclusion/exclusion switch for sending Device Reset Locally Notification.And reset to the Factory default. |
Inclusion |
Z-Wave primary controller into inclusion mode. And press the inclusion/exclusion switch for sending NIF. |
Exclusion |
Z-Wave primary controller into exclusion mode. And press 3 times the inclusion/exclusion switch for sending NIF. |
NIF |
XXXNIF |
Wakeup |
Case1. In the timeout-based scheme, the product is wakeup. Use 'wake up interval'.Case2. Physically scheme, include the product in a Z-Wave network, press the inclusion/exclusion switch for Wake Up Notification. |
Protection |
XXXProtection |
FirmwareUpdate |
XXXFirmwareUpdate |
SetAssociation |
XXXSetAssociation |
Association Groups:
Group Number |
Maximum Nodes |
Description |
1 |
1 |
Z-Wave Plus Lifeline;COMMAND_CLASS_BATTERY - REPORT commandCOMMAND_CLASS_NOTIFICATION - REPORT commandCOMMAND_CLASS_DEVICE_RESET_LOCALLY - NOTIFICATION command |
2 |
5 |
Notify a Z-Wave node that the door/window open or close, and the product case open/close has been detected.Nodes in this association group will receive;COMMAND_CLASS_NOTIFICATION - REPORT command |
3 |
5 |
Notify a Z-Wave node that the door/window open or close, and the product case open/close has been detected.Nodes in this association group will receive;COMMAND_CLASS_NOTIFICATION - REPORT command |
Technical Data
Hardware Platform |
ZM5202 |
Device Type |
Notification Sensor |
Network Operation |
Reporting Sleeping Slave |
Firmware Version |
HW: 1 FW: 1.00 |
Z-Wave Version |
6.61.00 |
Certification ID |
ZC10-16095235 |
Z-Wave Product Id |
0x0221.0x0003.0x0003 |
Firmware Updatable |
Updatable by Consumer by RF |
Color |
White |
Frequency |
XXfrequency |
Maximum transmission power |
XXantenna |