This is a
Put your Z-WaveController into inclusion mode, and follow the instructions to addMultisensor Duo to your controller. To get in the inclusion mode,the distance between sensor and controller should be up to 1 meter.Press the program switch of Multisensor Duo once. The LED on thesensor should stop flashing, if not, please try again.
Motion and temperature sensor in one device. ZipatoMultisensor Duo offers elaborate security and ambient sensingoptions. Multi-functional nature of this product allows you to detectmotion, and measure room temperature. When used with Zipatohome automation controllers it can be part of any automationscenario created using Zipato Rule Creator. Accordingly it can beused to automatically trigger other devices when activated.
Reset to factory default | Remove cover to trigged tamperswitch, LED ON & send out Alarm Report. Press Program Switch10 times within 10 seconds. Multisensor Duo will send the DeviceReset Locally Notification command and reset to the factorydefault settings. (Remark: This is to be done only in case of primarycontroller being inoperable or otherwise unavailable.) |
Inclusion | Put your Z-WaveController into inclusion mode, and follow the instructions to addMultisensor Duo to your controller. To get in the inclusion mode,the distance between sensor and controller should be up to 1 meter.Press the program switch of Multisensor Duo once. The LED on thesensor should stop flashing, if not, please try again. |
Exclusion | Put yourZ-Wave Controller into exclusion mode, and follow the instructionsto remove the Multisensor Duo from you controller network. Pressthe program switch of Multisensor Duo once to be excluded. TheLED on the Multisensor Duo should start to flash. |
NIF | XXXNIF |
Wakeup | It will be triggered after opening the front cover.Red LED will last 10 seconds and Multisensor Duo will send WakeUp Notification after 10 seconds. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
1 to 255 minutes to setup the re-trigger when there is nomovement detected in the period of time. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 127 | 1 to 127 minutes |
-128 - -1 | 128 to 255 minutes |
Select default temperature unit Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Celsius |
1 | Fahrenheit |
7 levels sensitivity, 1 = least sensitive, 7 = most sensitive, Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
1 - 7 | PIR sensitivity |
Hardware Platform | ZM5202 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 2 FW: 8.02:10.03 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-16095244 |
Z-Wave Product Id | 0x0131.0x2002.0x0205 |
Color | White |
Firmware Updatable | Updatable by Consumer by RF |
Sensors | Air TemperatureMotion/No Motion (Binary) |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |