This is a
enter the Inclusion Mode of gateway, and press the tamper switch 3 times within 1.5s,then the door sensor will stay in enrollment state until successfully enrolled into network or enrollment time out after 30s.
IM20_Zwave is a door/window sensor adopting Zwave500 series chip. It uses special structure design, suitable for kinds of installation environments. Also, it supports door & window open/close detection, anti-tamper, battery level detection and associated gateway and interaction device notifications.
Reset to factory default | Press the tamper switch 6 times in 2s, it will recover to factory setting after a period of timePlease use the reset procedure only when the primary controller is missing or inoperable |
Inclusion | enter the Inclusion Mode of gateway, and press the tamper switch 3 times within 1.5s,then the door sensor will stay in enrollment state until successfully enrolled into network or enrollment time out after 30s. |
Exclusion | enter the Exclusion Mode of gateway, and press the tamper switch 3 times within 1.5s, then the door sensor will be removed after a period of time. |
NIF | XXXNIF |
Wakeup | a) Manual Wake-upQuickly press tamper switch once, the door sensor will automatically send wake-up information, and there will be 10s after wake-up to receive gateway setting information.b) Automatic Wake-upDefault time of automatic wake-up is 24 hours, and there will be 10s after wake-up to receive gateway setting information, the max automatic report time = 24 hours, minimum=30min |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | 1.It will send NOTIFICATION_REPORTto the device in Group 1 when the door sensor is opened / closed, tamper switch is triggered / recovered.2.When in low battery status, door sensor will send BATTERY_REPORT to Group 1 device periodically.3.The door sensor will send DEVICE_RESET_LOCALLY_NOTIFICATION to Group1 devicewhen the device recovers to factory settings. |
2 | 2 | When the door sensor is opened, it will send BASIC SET command to control these devices in Group2. |
If there is any device under Association Group2, the door sensor will send Basic Set = value command to control that device when the door sensor is opened. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
1 - 100 | Dimmer Level |
255 | For ON/OFF Light Only |
If there is any device under Association Group2, the door sensor will send Basic Set = value command to Group2, and send Basic Set = 0x00 command to turn-off light after t seconds, Set value = t, means to send Basic Set command after t seconds. Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
1 - 120 | Turn Off Light Time |
Under normal working status (without trigger), the door sensor will automatically send report to the Gateway about its current tamper & open/close status. Set value = t, means t hours,(t=0, means no status report) Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 24 | Door Sensor Status Report Time |
Hardware Platform | ZM5202 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 255 FW: 1.38 |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-16105273 |
Z-Wave Product Id | 0x0214.0x0002.0x0001 |
Sensors | |
Color | |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |