This is a Notification Sensor for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
enter the Inclusion Mode of gateway, and press the tamper switch 3 times within 1.5s,then the door sensor will stay in enrollment state until successfully enrolled into network or enrollment time out after 30s.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

IM20_Zwave is a door/window sensor adopting Zwave500 series chip. It uses special structure design, suitable for kinds of installation environments. Also, it supports door & window open/close detection, anti-tamper, battery level detection and associated gateway and interaction device notifications.

Reset to factory default Press the tamper switch 6 times in 2s, it will recover to factory setting after a period of timePlease use the reset procedure only when the primary controller is missing or inoperable
Inclusion enter the Inclusion Mode of gateway, and press the tamper switch 3 times within 1.5s,then the door sensor will stay in enrollment state until successfully enrolled into network or enrollment time out after 30s.
Exclusion enter the Exclusion Mode of gateway, and press the tamper switch 3 times within 1.5s, then the door sensor will be removed after a period of time.
NIF XXXNIF
Wakeup a) Manual Wake-upQuickly press tamper switch once, the door sensor will automatically send wake-up information, and there will be 10s after wake-up to receive gateway setting information.b) Automatic Wake-upDefault time of automatic wake-up is 24 hours, and there will be 10s after wake-up to receive gateway setting information, the max automatic report time = 24 hours, minimum=30min
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 1.It will send NOTIFICATION_REPORTto the device in Group 1 when the door sensor is opened / closed, tamper switch is triggered / recovered.2.When in low battery status, door sensor will send BATTERY_REPORT to Group 1 device periodically.3.The door sensor will send DEVICE_RESET_LOCALLY_NOTIFICATION to Group1 devicewhen the device recovers to factory settings.
2 2 When the door sensor is opened, it will send BASIC SET command to control these devices in Group2.

Configuration Parameters

Parameter 1: Basic Set Level

If there is any device under Association Group2, the door sensor will send Basic Set = value command to control that device when the door sensor is opened.
Size: 1 Byte, Default Value: 255

Setting Description
1 - 100 Dimmer Level
255 For ON/OFF Light Only

Parameter 2: Turn Off Light Time Configuration

If there is any device under Association Group2, the door sensor will send Basic Set = value command to Group2, and send Basic Set = 0x00 command to turn-off light after t seconds, Set value = t, means to send Basic Set command after t seconds.
Size: 1 Byte, Default Value: 20

Setting Description
1 - 120 Turn Off Light Time

Parameter 3: Door Sensor Status Report

Under normal working status (without trigger), the door sensor will automatically send report to the Gateway about its current tamper & open/close status. Set value = t, means t hours,(t=0, means no status report)
Size: 1 Byte, Default Value: 12

Setting Description
0 - 24 Door Sensor Status Report Time

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 255 FW: 1.38
Z-Wave Version 6.51.09
Certification ID ZC10-16105273
Z-Wave Product Id 0x0214.0x0002.0x0001
Sensors
Color
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoNotification Sensor