This is a
1. Follow the instructions for your Z-Wave certifiedcontroller to add the smart dimmer to the Z-Wavenetwork.2. Once the controller is ready to add your smartdimmer, press and release the top or bottombutton on the smart dimmer to include it in thenetwork.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Transform any home into a smart home with the Jasco In-Wall Smart Motion Dimmer. This Z-Wave device replaces you current light switch using your existing wiring and provides Z-Wave wireless control of overhead lighting. The dimmer enables wireless control of On/Off functions of incandescent, LED, xenon, halogen and fluorescent lighting. Not only does it act as a dimmer but the Jasco In-Wall Smart Motion Dimmer has a built in PIR sensor which can control the local load and be set in occupancy or vacancy mode.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Press and release the top button ten times within 5seconds. The LED will flash 3 times quickly confirmingchange.Note: This should only be used in the event yournetworks primary controller is missing or otherwiseinoperable
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline, Multi-Level Report |
2 | 5 | Supports Basic Set and is controlled by pressing On/Off button with local load |
3 | 5 | Supports Basic Set and is controlled by pressing On/Off button with local load |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
0=Test(5S)1=1 minute5=5 minutes15=15 minutes30=30 minutes0xFF=Disable timeout Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 | Test(5S) |
1 | 1 minute |
5 | 5 minutes |
15 | 15 minutes |
30 | 30 minutes |
255 | Disable timeout |
Adjust timing of steps/levels Size: 2 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 2 | Steps/Levels |
3 | Default |
4 - 255 | Steps/Levels |
Adjust Steps/levels with ALL ON/OFF command Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | Default |
2 - 99 | Steps/Levels |
Adjust timing of steps/levels with ALL ON/OFF command Size: 2 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 2 | Steps/Levels |
3 | Default |
4 - 255 | Steps/Levels |
1=High sensitivity2=Medium sensitivity3=Low sensitivity Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
1 | High Sensitivity |
2 | Medium Sensitivity (Default) |
3 | Low Sensitivity |
0=Disabled1=Enabled Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disabled (Default) |
1 | Enabled |
0=Disable1=10 seconds2=20 seconds3=30 seconds4=45 seconds110 =27 mins 15 seconds Size: 2 Byte, Default Value: 2
Setting | Description |
---|---|
0 | Disable |
1 | 10 seconds |
2 | 20 seconds (Default) |
3 | 30 seconds |
4 | 45 seconds |
5 - 109 | 15 second intervals, starting at 60 seconds |
110 | 27 minutes 15 seconds |
0=Disabled1=Enabled Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disabled (Default) |
1 | Enabled |
0=Disabled1=Level 199=Level 99(full brightness) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disabled (Default) |
1 - 99 | Brightness Level |
0 = Dim up the light to the default level quickly1 = Dim up the light to the default level slowly Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Dim up the light to the default level quickly (Default) |
1 | Dim up the light to the default level slowly |
0 = Press any button on the switch1 = press and releaseX button, then press and releaseONbutton Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Press any button on the switch (Default) |
1 | Press and releaseX button, then press and releaseONbutton |
0xFF = last dimming level Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 99 | Brightness levels |
255 | Default |
1=Manual2=Vacancy3= Occupancy Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 | Manual |
2 | Vacancy |
3 | Occupancy |
In a 3-way configuration, invert the connected Add-On Switch buttons0=Disabled1=Enable Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disabled |
1 | Enabled |
0=Disabled1=Enable Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disabled |
1 | Enable |
Adjust steps/levels with Remote Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | Default |
2 - 99 | Steps/Levels |
Adjust timing of steps/levels with Remote Size: 2 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 2 | Steps/Levels |
3 | Default |
4 - 255 | Steps/Levels |
Adjust steps/levels Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | Default |
2 - 99 | Steps/Levels |
Hardware Platform | ZM5101 |
Device Type | Light Dimmer Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 255 FW: 5.50 |
Z-Wave Version | 6.51.08 |
Certification ID | ZC10-16125335 |
Z-Wave Product Id | 0x0063.0x494D.0x3033 |
Sensors | Motion/No Motion (Binary) |
Firmware Updatable | Updatable by Consumer by RF |
Neutral Wire Required | ok |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |