Quickstart

This is a secure Siren for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.- Insert the two 1.5V D-Cell alkaline batteries into the battery compartment connecting the correct polarity as shown on thebattery compartment lid.- The Bellbox will emit a 2-tone beep.Put the Z-Wave gateway or control panel into Inclusion mode (please refer to the Z-Wave gateway or control panel manual).- Within 1.5 seconds, press the Function Button 3 times.- Refer to the operation manual of the Z-Wave Gateway or Control Panel to complete the adding process.- If the sensor has already been added (included) into another Z-Wave Gateway/Control Panel, or if the sensor is unable to be added intothe current Z-Wave Gateway/Control Panel, please exclude it first (see Removing Device) before attempting to include it into the current Z-Wave Gateway/Control Panel.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

BX-32ZW is a battery-operated wireless outdoor siren generating a loud 107 decible siren sound and strobe lights to provide visible and audible alerts for possible intruders, emergencies, and safety incidents.The multi-functional outdoor bell box can work with the Control Panel to emit entry, exit delay, and low battery beeps. The BX-32ZW generates unique alarm sounds for fire and burglary to inform users of the type of danger at hand. Its tamper-deterrent feature protects against unauthorized removal and sabotage. The BX-32ZW is compatible with other manufacturers Z-Wave alarm systems.

Reset to factory default Factory Reset(Only use factory reset when network Control Panel/Gateway is missing or inoperable). - Press and hold the Function button of the Bellbox for 10 seconds tofactory reset with all LED flashes once. Factory resetting the Bellbox will restore it to factory defaultsettings (excluded from the Z-Wave network). The Z-Wave gatewayor control panel will still keep its Z-Wave settings. Please refer tothe gateway or control panel manual on how to remove theBellboxs Z-Wave settings.
Inclusion This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.- Insert the two 1.5V D-Cell alkaline batteries into the battery compartment connecting the correct polarity as shown on thebattery compartment lid.- The Bellbox will emit a 2-tone beep.Put the Z-Wave gateway or control panel into Inclusion mode (please refer to the Z-Wave gateway or control panel manual).- Within 1.5 seconds, press the Function Button 3 times.- Refer to the operation manual of the Z-Wave Gateway or Control Panel to complete the adding process.- If the sensor has already been added (included) into another Z-Wave Gateway/Control Panel, or if the sensor is unable to be added intothe current Z-Wave Gateway/Control Panel, please exclude it first (see Removing Device) before attempting to include it into the current Z-Wave Gateway/Control Panel.
Exclusion The Bellbox must be removed from existing Z-Wave network before being included into another. There are two methods available to exclude a device.Exclusion Mode - Put the Z-Wave gateway or control panel into Exclusion mode(please refer to the Z-Wave gateway or control panel manual). - Within 1.5 seconds, press the Function Button 3 times and theBellbox will be removed from the Z-Wave network.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Group 1 for LifeLine (maximum node:1): Battery CC (COMMAND_CLASS_BATTERY) Notification CC,V4 (COMMAND_CLASS_NOTIFICATION) SwitchBinary CC, V1 (COMMAND_CLASS_SWITCH_BINARY) Device Reset Locally CC
2 5 Group 2 for Tamp rep (maximum node: 5):Notification CC,V4 (COMMAND_CLASS_NOTIFICATION)When Tamper Open, Group 2 send Notification(Type:07,Event:03), Tamper Close send Notification(Type:07,Event:00,Parameter:03)
3 5 Group 3 for AC rep (maximum node: 5):Notification CC,V4 (COMMAND_CLASS_NOTIFICATION)When AC Fail send Notification (Type:08,Event:02),When AC Restore send Notification (Type:08, Event:03)

Technical Data

Hardware Platform ZM5101
Device Type Siren
Network Operation Listening Sleeping Slave
Firmware Version HW: 255 FW: 1.04
Z-Wave Version 6.61.00
Certification ID ZC10-17015385
Z-Wave Product Id 0x018E.0x0002.0x000B
Firmware Updatable Updatable by Professional/Technician
IP (Ingress Protection) Rated ok
Outdoor Use ok
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Siren