To manually include the device, press Tamper three times repeatedly to perform the actions.LED Status:Blue LED solid light
The Door/Window Sensor is a wireless, battery powered, Z-Wave compatible reed sensor.Each time the sensors body and a magnet separate, a radio signal is sent.In addition, the Door/Window Sensor supports one potential-free input and self-power adapter of DC 9V~30V.The Door/Window Sensor is designed for use with home automation systems, alarm and surveillance systems and everywhere else where information related to opening/closing of doors, garage, gates.
Reset to factory default | The Device Reset Locally Notification Command is used to advertise that the device will be reset to default.In Wake up time, Press tamp key 2 times, then the third long press 5s, then device will clear the data back to the factory default.Please use this procedure only when the network primary controller is missing or otherwise inoperable. |
Inclusion | To manually include the device, press Tamper three times repeatedly to perform the actions.LED Status:Blue LED solid light |
Exclusion | To manually exclude the device, press Tamper three times repeatedly to perform the actions.LED Status:Blue LED 1 sec. flashes 3 times |
NIF | XXXNIF |
Wakeup | The Z-Wave Window/Door Sensor stays in sleep status for the majority of time in order to conserve battery power. However, it can be woken up at specified intervals by setting WAKE_UP_INTERVAL_SET command. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Group1:u0022Lifelineu0022 :Group1 is used to send Sensor trigger status(BATTERY, NOTIFICATION, DEVICE_RESET_LOCALLY NOTIFICATION) to the controller. |
2 | 5 | Group2:u0022Sensor Reed repu0022:When the Sensor Reed rep is triggered, a NOTIFICATION REPORT is sent to the Device in Group2. |
3 | 5 | Group3:u0022Sensor Tamper repu0022:When the Sensor Tamper rep is triggered, a NOTIFICATION REPORT is sent to the Device in Group3. |
4 | 5 | Group4:u0022Sensor S1 repu0022: When the Sensor S1 rep is triggered, a NOTIFICATION REPORT is sent to the Device in Group4. |
5 | 5 | Group5:u0022Sensor S2 repu0022:When the Sensor S2 rep is triggered, a NOTIFICATION REPORT is sent to the Device in Group5. |
The interval time of sending Battery Report when the battery runs out of electricity. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 30 | minute |
Set the configuration of 2 external sensors.0 (00b): S1 NO, S2 NO1 (01b):S1 NO,S2 NC2 (10b):S1 NC,S2 NO3 (11b):S1 NC,S2 NC Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 3 | External Sensor Define |
Hardware Platform | ZM5101 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 255 FW: 2.14 |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-17015396 |
Z-Wave Product Id | 0x0068.0x0003.0x0009 |
Sensors | Open/Closed (Binary) |
Firmware Updatable | Updatable by Manufacturer |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |