Put the Z-Wave Interface Controller into inclusion mode, and following its instruction to add the ZS 5101-5 to your controller.To get in the inclusion mode, please press the program switch of ZS 5101-5 for 1 second at least to be included. The LED on the ZS 5101-5 should go off, if not, please try again.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

ZS5101US-5 detects vibrations made by an intruder attempting to break a window or door.It detects tamper situations and will send Z-Wave a signal when vibrations or tamper situations occur.When this device is securely included into the Z-Wave network, the above communications will be encrypted. * Non-Touch Vibration Design for Longer Lifetime* Adjustable Sensitivity* Tamper Switch* Battery Detection* LED Status Indicator* Battery Life: 2 Years

Reset to factory default *Push the Tamper switch then power on (put in the battery) & hold the Tamper switch for 5 seconds, ZD5101-5 will send the Device Reset Locally Notification command and reset to the factory default, LED will solid on, need to take off the battery and re-put in the battery to complete the function.*Please use this procedure only in the event that the network primary controller is missing or otherwise inoperable.
Inclusion Put the Z-Wave Interface Controller into inclusion mode, and following its instruction to add the ZS 5101-5 to your controller.To get in the inclusion mode, please press the program switch of ZS 5101-5 for 1 second at least to be included. The LED on the ZS 5101-5 should go off, if not, please try again.
Exclusion Put the Z-Wave Interface Controller into exclusion mode, and following its instruction to delete the ZS 5101-5 from your controller.Press the program switch of ZS 5101-5 for 1 second at least to be excluded.
NIF XXXNIF
Wakeup Use Wake Up command to set up the awaking time and send the wake up notification to controller.User can use command to change the auto wake up from 500 seconds to 1 week, Interval increment is 250 seconds. (Default: 6 hours)*Use Battery Get command to have the battery capacity back in %
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 1 FW: 16.11
Z-Wave Version 6.51.09
Certification ID ZC10-17015397
Z-Wave Product Id 0x0109.0x2003.0x0308
Sensors Vibration/Shock (Binary)
Color White
Frequency XXfrequency
Maximum transmission power XXantenna