Quickstart

This is a Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
-Click [Add] icon in Z-Wave Controller.-Press the Net_Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second.-If Inclusion Process is successful, Green LED will turn off.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Smart Temperature and Humidity Sensor is designed to detect the temperature and humidity in house, and reports the abnormal conditions to users' mobile phone, Users could also check the real-time temperature and humidity via mobile phone, The sensor adopts Z-Wave wireless communication protocol with high sensitivity.

Reset to factory default -Long press Net_Button while installing batteries in the product. - Device Reset Locally notification is Transmitted.- use the reset procedure only when the primary controller is missing or inoperable.
Inclusion -Click [Add] icon in Z-Wave Controller.-Press the Net_Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second.-If Inclusion Process is successful, Green LED will turn off.
Exclusion -Click [Remove] icon in Z-Wave Controller.-Press the Net_Button 3 times within 1.5s -If Exclusion Process is successful, Green LED is Blinking 6 times, then turn off
NIF XXXNIF
Wakeup Wake up Notification is transmitted every 24 hours by default.-Wake up Notification is transmitted after Notification Report is Transmitted
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Association group 1: Lifeline association groupMaximum supported node is 1.Include command classes: Battery report, multilevel sensor report, and Device Reset Locally.
2 5 Association group 2: Root Device group(multilevel sensor temperature)Maximum supported nodes are 5.1-multilevel Sensor reports status of the temperature via Lifeline.2-When the sensor detects status of the temperature, the device will be triggered.
3 5 Association group 3: Root Device group(multilevel sensor humidity)Maximum supported nodes are 5.1-multilevel Sensor reports status of the humidity via Lifeline.2-When the sensor detects status of the humidity , the device will be triggered.

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 11 FW: 2.00
Z-Wave Version 6.51.09
Certification ID ZC10-17055578
Z-Wave Product Id 0x0260.0x8007.0x1000
Controller Supports Multiple Networks ok
IP (Ingress Protection) Rated ok
Sensors Air TemperatureHumidity
Supported Notification Types Weather Alarm
Color White
Communications Protocol Z-Wave Serial API
Communications Connections Ethernet (Wireless/WiFi)
Firmware Updatable Not Updatable
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Notification Sensor