Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action Button that you can find on the product.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Aeotec by Aeon Labs Water Sensor 6 brings intelligence to a new level, one that is suited to both safety and convenience. It contains 4 sensing points, which would be more accurately to detect the presence and absence of water or detect whether there is water leak in some places of your home. The Water Sensor 6 has an inbuilt buzzer that can play alarm sounds to let you know when the water is detected.The Water Sensor 6 is also a security Z-Wave device that supports Over The Air (OTA) for firmware updates.

Reset to factory default Press and hold the Action Button that you can find on the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable.
Inclusion Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action Button that you can find on the product.
Exclusion Turn the primary controller of Z-Wave network into exclusion mode, short press the products Action Button that you can find on the product.
NIF XXXNIF
Wakeup Pressing the Action Button once will trigger sending the Wake up notification command. If press and hold the Z-Wave button for 3 seconds, the Water Sensor will wake up for 10 minutes.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Lifelinegroup.1. The Battery Report or Multilevel Sensor Report (Configurable) can be sent to the associated nodes in group 1.2. When the water leak is detected, the Notification Report will be send to the associated nodes in group 1.3. When the Water Sensor is reset, the Device Reset Locally CC will be send to the associated nodes in group 1.
2 5 Send the configuration parameter 0x88 to the associated nodes in group 2.
3 5 Send Basic Set (configured by parameter 0x58) to the associated nodes in Group 3 when the Sensor probe 1 is triggered.
4 5 Send Basic Set (configured by parameter 0x59) to the associated nodes in Group 4 when the Sensor probe 2 is triggered.

Configuration Parameters

Parameter 10: Set the alarm time for the Buzzer when the sensor is triggered.

Set the alarm time for the Buzzer when the sensor is triggered.
Size: 4 Byte, Default Value: 101968650

Setting Description
1 - 255 Repeated cycle of Buzzer alarm.
256 - 65535 the time of Buzzer keeping ON state (MSB)
65536 - 2147483647 The time of Buzzer keeping OFF state

Parameter 101: To set what unsolicited report would be sent to the Lifeline group.

To set what unsolicited report would be sent to the Lifeline group.
Size: 1 Byte, Default Value: 3

Setting Description
3 Battery Report and Multilevel sensor report for temperature are enabled.
1 Battery Report is enabled.
0 Send Nothing
2 Multilevel sensor report for temperature is enabled.

Parameter 111: To set the interval time of sending reports in Report group 1

To set the interval time of sending reports in Report group 1.Note:1. The unit of interval time is second if USB power.2. If battery power, the minimum interval time is equal to Wake Up interval set by the Wake Up CC.
Size: 4 Byte, Default Value: 3600

Setting Description
5 - 2678400 Available rang is 5 to 2678400 seconds.

Parameter 135: To set which sensor report can be sent when the water leak event is triggered and if the receiving device is a non-multichannel device.

To set which sensor report can be sent when the water leak event is triggered and if the receiving device is a non-multichannel device.
Size: 1 Byte, Default Value: 1

Setting Description
0 Send nothing
3 Send notification report to association group 1 and Send configuration 0x88 report to association group 2.
1 Send notification report to association group 1.
2 Send configuration 0x88 report to association group 2.

Parameter 136: When the parameter 0x87 is set to 2 or 3, it can get the sensor probes status through this configuration value.

When the parameter 0x87 is set to 2 or 3, it can get the sensor probes status through this configuration value.Note: This parameter is a Get- only parameter.
Size: 1 Byte, Default Value: 0

Setting Description
0 absence of water is triggered by probe 1.
1 presence of water is triggered by probe 1.
2 presence of water is triggered by probe 2.

Parameter 2: Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor.

Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor.
Size: 1 Byte, Default Value: 0

Setting Description
1 Enable.
0 Disable

Parameter 201: Temperature sensor calibration

Temperature sensor calibration.Note:1.High byte is the calibration value. Low byte is the unit (0x00=Celsius, 0x01=Fahrenheit)2.The calibration value (high byte) contains one decimal point. E.g. if the value is set to 20 (0x1400), the calibration value is 2.0(EU/AU version) or if the value is set to 20 (0x1401), the calibration value is 2.0 (US version)3.The calibration value (high byte) = standard value - measure value.E.g.If measure value =25.3 and the standard value = 23.2, so the calibration value= 23.2 - 25.3= -2.1 (0xEB).If the measure value =30.1 and the standard value = 33.2, so the calibration value= 33.2 - 30.1=3.1 (0x1F).
Size: 2 Byte, Default Value: 1

Setting Description
-128 - 127 Available rang is -12.8 to 12.7.

Parameter 252: Enable/disable all configuration parameters to be locked

Enable/disable all configuration parameters to be locked.
Size: 1 Byte, Default Value: 0

Setting Description
1 Enable.
0 Disable

Parameter 255: Reset to factory defaults.

Reset to factory defaults.
Size: 4 Byte, Default Value: 0

Setting Description
1431655765 Reset the product to factory defaults.
1 Reset all configuration parameters to factory defaults.

Parameter 39: Configure the default low battery value.

Configure the default low battery value. When the current battery level is lower than this value, it will send out the low battery alarm.
Size: 1 Byte, Default Value: 20

Setting Description
10 - 50 Available rang is 10% to 50%.

Parameter 48: Enable/disable the sensor report

Enable/disable the sensor report
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable.

Parameter 49: Set the upper limit value (overheat).

Set the upper limit value (overheat).
Size: 4 Byte, Default Value: 68157696

Setting Description
0 Celsius unit
1 Fahrenheit unit
65536 - 2147483647 Temperature value

Parameter 50: Set the lower limit value (under heat)

Set the lower limit value (under heat)
Size: 4 Byte, Default Value: 20971776

Setting Description
0 Celsius unit
1 Fahrenheit unit
65536 - 2147483647 Temperature value

Parameter 57: Set the recover limit value of temperature sensor.

Note:1. When the current measurement <= (Upper limitRecover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. After that the upper limit report would be disabled again until the measurement <= (Upper limitRecover limit).2. When the current measurement >= (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. After that the lower limit report would be disabled again until the measurement >= (Lower limit + Recover limit).3. High byte is the recover limit value. Low byte is the unit (0x01=Celsius, 0x02=Fahrenheit).
Size: 2 Byte, Default Value: 5121

Setting Description
10 - 255 Available rang is 1.0 to 25.5

Parameter 64: Set the default unit of the automatic temperature report in parameter 101-103.

Set the default unit of the automatic temperature report in parameter 101-103.
Size: 1 Byte, Default Value: 1

Setting Description
1 The unit is Fahrenheit.
0 The unit is Celsius.

Parameter 8: Set the timeout of awake after the Wake Up CC is sent out..

Set the timeout of awake after the Wake Up CC is sent out..
Size: 1 Byte, Default Value: 30

Setting Description
8 - 127 Available rang is 8 to 127 seconds.

Parameter 84: Get the state of tilt sensor

Get the state of tilt sensor.Note: this is a Get-only parameter.
Size: 1 Byte, Default Value: 0

Setting Description
0 The Water Sensor main unit is in horizontal direction.
1 The Water Sensor main unit is in vertical direction.

Parameter 86: Enable/ disable the buzzer.

Enable/ disable the buzzer.
Size: 1 Byte, Default Value: 1

Setting Description
1 Enable
0 Disable

Parameter 87: To set which sensor is triggered the buzzer will alarm.

To set which sensor is triggered the buzzer will alarm.
Size: 4 Byte, Default Value: 55

Setting Description
1 If the Water leak is triggered, the buzzer will alarm.
2 If the vibration is triggered, the buzzer will alarm.
4 If the tilt sensor is triggered, the buzzer will alarm.
16 If the under heat is triggered, the buzzer will alarm
32 If the overheat is triggered, the buzzer will alarm.

Parameter 88: To set which value of the Basic Set will be sent to the associated nodes in association Group 3 when the Sensor probe 1 is triggered.

To set which value of the Basic Set will be sent to the associated nodes in association Group 3 when the Sensor probe 1 is triggered.
Size: 1 Byte, Default Value: 0

Setting Description
1 Presence of water, send Basic Set 0xFF, absence of water, send Basic Set 0x00.
2 Presence of water, send Basic Set 0x00, absence of water, send Basic Set 0xFF.
0 Send nothing

Parameter 89: To set which value of the Basic Set will be sent to the associated nodes in association Group 4 when the Sensor probe 2 is triggered.

To set which value of the Basic Set will be sent to the associated nodes in association Group 4 when the Sensor probe 2 is triggered.
Size: 1 Byte, Default Value: 0

Setting Description
2 Presence of water, send Basic Set 0x00, absence of water, send Basic Set 0xFF.
0 Send nothing.
1 Presence of water, send Basic Set 0xFF, absence of water, send Basic Set = 0x00.

Parameter 9: Report the current power mode and the product state for battery power mode

Report the current power mode and the product state for battery power mode.Note: this parameter cannot be used as Set usage.
Size: 2 Byte, Default Value: 0

Setting Description
257 Keep awake for 10 minutes for battery power mode.
256 Keep sleep state for Battery power mode
0 USB power mode

Parameter 94: To set which power source level is reported via the Battery CC.

To set which power source level is reported via the Battery CC.
Size: 1 Byte, Default Value: 0

Setting Description
0 report the USB power level.
1 report the CR123A battery level.

Technical Data

Hardware Platform ZM5101
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 122 FW: 1.01
Z-Wave Version 6.51.09
Certification ID ZC10-17055616
Z-Wave Product Id 0x0086.0x0202.0x007A
Supported Notification Types Heat AlarmHome SecurityWater Alarm
Sensors Air TemperatureWater Flow
IP (Ingress Protection) Rated ok
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
Australia / New ZealandNotification Sensor