This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. -Insert the two 1.5V D-Cell alkaline batteries into the battery compartment connecting the correct polarity as shown on thebattery compartment lid.The Bellbox will emit a 2-tone beep. -Put the Z-Wave gateway or control panel into Inclusion mode (please refer to the Z-Wave gateway or control panel manual). -Within 1.5 seconds, press the Function Button 3 times. -Refer to the operation manual of the Z-Wave Gateway or Control Panel to complete the adding process. -If the sensor has already been added (included) into another Z-Wave Gateway/Control Panel, or if the sensor is unable to be added into the current Z-Wave Gateway/Control Panel, please exclude it first (see Removing Device) before attempting to include it into the current Z-Wave Gateway/Control Panel.
BX-35ZW bell box is a battery-operated wireless outdoor siren generating a loud 105 decibel siren sound and strobe lights during an alarm to provide visible and audible alerts. Encased in a durable, IPX5 waterproof elegant design, easy-to-install BX-35ZW is a premium choice for the modern smart home.The BX-35ZW is energy saving and environmentally conscious, requiring only two Alkaline batteries, yet still has a long battery life of up to 3.5 years. The BX-35ZW generates unique alarm sounds for fire and burglary to inform users of the type of danger at hand. It provides programmable siren duration of 3, 5, and 10 minutes.In addition to producing audible and visible warnings in the case of emergency, the BX-35ZW emits beep notifications for arming and disarming of a security system, and of its low battery status. Its tamper-deterrent feature protects against unauthorized removal and sabotage. The BX-35ZW is compatible with others Z-Wave systems.
Reset to factory default | (Only use factory reset when network Control Panel/Gateway is missing or inoperable). -Press and hold the Function button of the Bellbox for 10 seconds to factory reset with all LED flashes once. |
Inclusion | This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. -Insert the two 1.5V D-Cell alkaline batteries into the battery compartment connecting the correct polarity as shown on thebattery compartment lid.The Bellbox will emit a 2-tone beep. -Put the Z-Wave gateway or control panel into Inclusion mode (please refer to the Z-Wave gateway or control panel manual). -Within 1.5 seconds, press the Function Button 3 times. -Refer to the operation manual of the Z-Wave Gateway or Control Panel to complete the adding process. -If the sensor has already been added (included) into another Z-Wave Gateway/Control Panel, or if the sensor is unable to be added into the current Z-Wave Gateway/Control Panel, please exclude it first (see Removing Device) before attempting to include it into the current Z-Wave Gateway/Control Panel. |
Exclusion | The Bellbox must be removed from existing Z-Wave network before being included into another. There are two methods available to exclude a device. -Put the Z-Wave gateway or control panel into Exclusion mode (please refer to the Z-Wave gateway or control panel manual). -Within 1.5 seconds, press the Function Button 3 times and the Bellbox will be removed from the Z-Wave network. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Group 1 for LifeLine (maximum node:1):Battery CC (COMMAND_CLASS_BATTERY)Notification CC,V4 (COMMAND_CLASS_NOTIFICATION)SwitchBinary CC, V1 (COMMAND_CLASS_SWITCH_BINARY)Device Reset Locally CC |
2 | 5 | Group 2 for Tamp rep (maximum node: 5):Notification CC,V4 (COMMAND_CLASS_NOTIFICATION)When Tamper Open, Group 2 send Notification(Type:07,Event:03), Tamper Close send Notification(Type:07,Event:00,Parameter:03) |
3 | 5 | Group 3 for AC rep (maximum node: 5):Notification CC,V4 (COMMAND_CLASS_NOTIFICATION)When AC Fail send Notification (Type:08,Event:02),When AC Restore send Notification (Type:08, Event:03) |
Maximum siren length.0x01~0x0A (1~10 min), default 0x0A. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 10 | 1 minute to 10 minutes |
Upon siren trigger, LED flash enable/disable.0x00: disable, 0x01: enable; default 0x01 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | 0:disable, 1: enable |
Comfort LED flash every sec, 0~250sec, each unit is 10 sec.0x00~0x19 (disable, 10sec,,250sec)default:0x00 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 25 | 0 sec to 250 sec, the unit is 10 sec |
Tamper Enable/Disable0x00:disable, 0x01: enabledefault 0x01 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | 0:disable, 1: enable |
Hardware Platform | ZM5101 |
Device Type | Siren |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 255 FW: 1.04 |
Z-Wave Version | 6.61.00 |
Certification ID | ZC10-17055618 |
Z-Wave Product Id | 0x018E.0x0002.0x0011 |
Communications Protocol | Z-Wave Serial API |
Outdoor Use | ok |
Color | Red |
Firmware Updatable | Updatable by Professional/Technician |
Supported Notification Types | Home SecurityPower Management |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |