Quickstart

This is a secure Door Lock - Keypad for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
1. Enter the 4-8 digit master PIN code followed by the gear key.2. Press the 7 key followed by the gear key.3. Press the 1 key followed by the gear key.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Yale nexTouch provides small business owners a wireless access management solution with the security of commercial grade locks and the convenience and cost-efficiency of wireless installation. The nexTouch product is a keypad access lock designed to meet most small business applications, both interior and exterior. The lock can be paired with a Z-Wave system for easy integration into new and existing alarm and automation platforms.Yale nexTouch offers many benefits for the small business owner, including easy management of employee access rights and attendance, seeing to unattended deliveries, monitoring of business hours, managing remote locations, and increased security. Lock features may vary based on the chosen integration system, but typically include accommodation of up to 500 users, real-time notifications, audit trail, scheduling of access rights and remote access. To meet small business security needs Yale nexTouch locks are ANSI/BHMA Grade 1 certified, UL listed for use on fire doors and windstorm listed. The product is designed for standard commercial doors, ideal for employee, delivery or back entrances. The lock is available with a backlit push button or touchscreen keypad, the latter offering low battery and tamper alarm indicators on the device.

Reset to factory default Please use this procedure only when the network primary controller is missing or otherwise inoperable.1. Remove the inside lever with the lever removal tool.2. Remove battery cover using hex wrench provided with lock.3. Remove four (4) AA batteries.4. Remove the 10-32 x 3/4" pan head screw from the center of the battery housing into the barrel nut of the outside assembly.5. Remove inside escutcheon. Cables may stay connected.6. Reinstall batteries 7. On the back of the PC board, push and hold the Reset Button with the lever removal tool for 3 seconds.8. While continuing the press the reset button, temporarily remove one AA battery.9. Reinstall the battery10. Release reset button and wait 15 seconds. Speaker will announce "Welcome to Yale"11. Reassemble escutcheon
Inclusion 1. Enter the 4-8 digit master PIN code followed by the gear key.2. Press the 7 key followed by the gear key.3. Press the 1 key followed by the gear key.
Exclusion 1. Enter the 4-8 digit master PIN code followed by the gear key.2. Press the 7 key followed by the gear key.3. Press the 3 key followed by the gear key.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 1: Silent Mode on/off

Level control, 1, 2, 3 default is 1. Levels are 1 and 3 for models with no spoken prompts default is 1 or high
Size: 1 Byte, Default Value: 1

Setting Description
1 - 3 Level

Parameter 11: One Touch Locking

0x00 = OFF, 0xFF = ON default is 0xFF or ON.
Size: 1 Byte, Default Value: 0

Setting Description
0 One Touch Locking Off
-128 One Touch Locking On

Parameter 12: Privacy Button

0x00 = OFF, 0xFF = ON default is 0x00 or OFF
Size: 1 Byte, Default Value: 0

Setting Description
0 Privacy Button Off
-128 Privacy Button On

Parameter 15: Reset to Factory Defaults

01 = Lock will execute Reset To Factory.02 = Reserved for future use (Lock will currently execute Reset To Factory same as 01). No default valuePlease use this procedure only when the network primary controller is missing or otherwise inoperable
Size: 1 Byte, Default Value: 0

Setting Description
0 Reset to Factory Off
-128 Reset to Factory On

Parameter 18: Door Propped Timer

10 to 127 second.This value is represented as seconds X 10. (ie a value of 4 would mean a door propped timer of 40 seconds) Set to 0x00 to disable Door Propped Alarm.Default = 0x00 (off)
Size: 1 Byte, Default Value: 0

Setting Description
20 - 127 Seconds

Parameter 19: DPS Alarm

0x00 = OFF, 0xFF = ON Default is 0x00 or off.Used to enable/disable door condition alarms for locks that support a door position sensor.Any lock that does not support DPS will always report 0x00.
Size: 1 Byte, Default Value: 0

Setting Description
0 DPS Alarm Off
-128 DPS Alarm On

Parameter 2: Auto Relock On/Off

0x00 = OFF, 0xFF = ON default is 0x00 or OFF
Size: 1 Byte, Default Value: 0

Setting Description
0 Auto Relock Off
-128 Auto Relock On

Parameter 3: Auto Relock Time

10 to 127 seconds default is 5 seconds
Size: 1 Byte, Default Value: 5

Setting Description
10 - 127 Seconds

Parameter 4: Wrong Code Entry Limit

3 to 10 default is 5 times
Size: 1 Byte, Default Value: 5

Setting Description
3 - 10 Times

Parameter 5: Language

Set the lock language. Default is 1= English
Size: 1 Byte, Default Value: 1

Setting Description
1 English Language
2 Spanish Language
3 French Language

Parameter 7: Shut Down Time (after wrong code entries)

10 to 127 seconds default is 60 seconds
Size: 1 Byte, Default Value: 60

Setting Description
10 - 127 Seconds

Parameter 8: Operating Mode

This sets the operating mode for the lock.
Size: 1 Byte, Default Value: 0

Setting Description
0 Normal Mode (Default)
1 Vacation Mode (Keypad Locked Out)
2 Privacy Mode (Keypad Locked, RF Unlock Functional)

Technical Data

Hardware Platform ZM5101
Device Type Door Lock - Keypad
Network Operation Listening Sleeping Slave
Firmware Version HW: 255 FW: 1.67:15.00
Z-Wave Version 6.51.07
Certification ID ZC10-17065634
Z-Wave Product Id 0x0129.0x8001.0x0B00
Supported Notification Types Access ControlPower Management
Outdoor Use ok
IP (Ingress Protection) Rated ok
Firmware Updatable Updatable by Consumer by RF
Door Lock Type Lever Handle
Color Chrome
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoDoor Lock - Keypad