This is a
Put the Z-Wave Controller in inclusion mode. Pressing tamper key three times within 1.5 seconds will enter inclusion mode.Aftersuccessfulinclusion,thedevicewillwaketoreceivethe setting command from Z-Wave Controller in about 20 seconds.
Zipato Multisensor Trio offers elaborate security and ambient sensing options. Multifunctional nature of this product allows you to monitor opened/closed status of any opening object, measureroomsambienttemperatureandlightintensity.
Reset to factory default | Use this procedure only in the event that the primary controller is lost or otherwise inoperable.Pressing tamper key four times within 1.5 seconds and during 4th press, hold the tamper key until LED lights up. After 3 seconds the LED will turn OFF, and after next 2 seconds, release the tamper key. If successful, the LED will light ON for one second. Otherwise, the LED will flash once.IDs are excluded and all settings will reset to factory default. |
Inclusion | Put the Z-Wave Controller in inclusion mode. Pressing tamper key three times within 1.5 seconds will enter inclusion mode.Aftersuccessfulinclusion,thedevicewillwaketoreceivethe setting command from Z-Wave Controller in about 20 seconds. |
Exclusion | Put the Z-Wave Controller in exclusion mode. Pressing tamper key three times within 1.5 seconds will enter exclusion mode. Node ID has been excluded. |
NIF | XXXNIF |
Wakeup | If the user want to wake-up the device immediately, please remove the front cover, and press the tamper key once. The device will wake-up 10 seconds. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 8 | Z-Wave Plus Lifeline |
2 | 8 | Lighting group control |
The interval time for auto report the battery level. 0 means turn off auto report battery.The default value is 12. The tick time can setting by the configuration No.20. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 127 | The interval time forauto report the batterylevel. |
The interval time for auto report the door/window state. 0 means turn off auto reportdoor/window state. The default value is 12. The tick time can setting by the configuration No.20. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 127 | The interval time forauto report the door/ window state. |
The interval time for auto report the illumination. 0 means turn off auto report illumination. The default value is 12. The tick time can setting by the configuration No.20. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 127 | The interval timefor auto report theillumination. |
The interval time for auto report the temperature. 0 means turn off auto report illumination. The default value is 12. The tick time can setting by the configuration No.20. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 127 | The interval timefor auto report theillumination. |
Setting the BASIC command value toturn on the light. The 0xFF(-1) means turn on the light. For dimmer equipment 1 to 100 means the light strength. Size: 1 Byte, Default Value: -1
Setting | Description |
---|---|
-128 - 127 | Setting the BASICcommand value to turn on the light. |
The interval time for auto report each tick. Setting this configuration willeffect configuration No.10, No.11, No.12 and No.13. Caution: Setting to 0 means turn offall auto report function. Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
-128 - 127 | The interval timefor auto report eachtick. |
The temperature differential to report.0 means turn off this function. The unit is Fahrenheit. Enable this function the device willdetect every minutes.And when the temperature is over 140degree Fahrenheit, it will continue report.Enable this functionality will cause some issue please see the detail in the Temperature Report section. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 127 | The temperaturedifferential to report. |
The illumination differential to report.0 means turn off this function. The unit is percentage. Enable this function the device willdetect every minutes.Enable this functionality will cause some issue please see the detail in the Illumination Report section. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 99 | The illuminationdifferential to report. |
Setting the illumination threshold to turn on the light. When the event triggered and the environment illumination lowerthen the threshold, the device will turnon the light.0 means turn off illumination detectedfunction. And never turn on the light.1 means darkest.99 means brightest.100 means turn off illumination detectedfunction. And always turn on the light.Notice: In none test mode, only thevalue in 1 to 99 will enable theillumination detected function andupdate the illumination value. Size: 1 Byte, Default Value: 99
Setting | Description |
---|---|
0 - 100 | Setting the illuminationthreshold to turnon the light. |
Operation mode. Using bit to control. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
2 | 1 means testmode, 0 means normalmode. |
4 | Disable the door/ window function. |
8 | Setting thetemperature scale. |
16 | Disable theillumination report after event triggered. |
32 | Disable thetemperature report after event triggered. |
-128 | Disable the backkey release into testmode. |
Multisensor function switch. Using bitto control. Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
2 | Disable PIRintegrate Illumination toturn ON the lighting nodes in the associationgroup 2. |
4 | Disable magneticintegrate PIR to turnON the lighting nodesin the association group2. |
8 | When Bit2 is 0(Enable), Are the deviceand the lighting in thesame room? |
16 | Disable delay5 seconds to turnoff the light, whendoor/window closed. |
32 | Disable auto turnoff the light, after door/ window opened to turnon the light. |
1 | Disable magneticintegrate illumination toturn ON the lighting nodes in the associationgroup 2. |
Customer function switch, using bit control. Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
32 | Disable Multi CC inauto report. |
64 | Disableto report batterystate when the devicetriggered. |
2 | Enable sendingmotion OFF report. |
4 | Enable PIR supersensitivity mode. |
8 | Disable send outBASIC OFF after doorclosed. |
16 | Notification Type, 0: Using NotificationReport. 1: Using SensorBinary Report. |
After turn on the lighting, setting thedelay time to turn off the lighting when the PIR motion is not detected. 8 seconds per tick, default tick is 4 (32 seconds).0 means never send turn off light command. Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
0 - 127 | After turn on thelighting, setting the delay time to turnoff the lighting whenthe PIR motion is notdetected. |
Hardware Platform | SD3502 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 1.24:01.20 |
Z-Wave Version | 6.51.02 |
Certification ID | ZC10-17065645 |
Z-Wave Product Id | 0x0131.0x0002.0x000C |
Sensors | HeatHumidityLuminance |
Supported Notification Types | Home Security |
Color | White |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |