Quickstart
This is a
secure
On/Off Power Switch for XXXQFrequencyName.
To run this device please make sure the internal battery is fully charged.
To add this device to your network execute the following action:
This must be done when the DoorCam is in an excluded status, which means that it is not a part of any Z-Wave network; you will know this because the Z-Wave LED will remain on.After starting the inclusion process on your Z-Wave controller, please do the following:a. Press & hold the Z-Wave inclusion button for 5 seconds.b. When the Z-Wave LED blinks rapidly, release the Z-Wave inclusion button.c. The DoorCam will try inclusion for 30 seconds.d. If inclusion was successful, the Z-Wave LED will turn off.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from
Z-Wave Alliance Product
data and may be incomplete. Please refer to the
Manufacturers Manual for more information.
Product Description
LG Uplus IoT DoorCam streams live video feed to your phone remotely. The app receives push notifications of different activities and record motion videos when visitors arrive. It also checks the battery life with the app and receives reminders when the battery is low.
Reset to factory default |
a. Hold the Z-Wave button for 10 seconds.(Z-Wave LED will blink after 5 seconds with 250ms interval then Z-Wave LED will be turned off after another 5 seconds.)b. When Z-Wave LED stops blinking after 10 seconds, release Z-Wave button.c. When factory reset is successful, LED will be on.Please use this procedure only if the network primary controller is missing or inoperable. |
Inclusion |
This must be done when the DoorCam is in an excluded status, which means that it is not a part of any Z-Wave network; you will know this because the Z-Wave LED will remain on.After starting the inclusion process on your Z-Wave controller, please do the following:a. Press & hold the Z-Wave inclusion button for 5 seconds.b. When the Z-Wave LED blinks rapidly, release the Z-Wave inclusion button.c. The DoorCam will try inclusion for 30 seconds.d. If inclusion was successful, the Z-Wave LED will turn off. |
Exclusion |
This must be done when the DoorCam is in an included status, which means that it is a part of any Z-Wave network; you will know this because the Z-Wave LED will remain off.After starting the exclusion process on your Z-Wave Controller, please do the following.a. Press & hold Z-Wave button for 5 seconds when DoorCam is inclusion status.b. When Z-Wave LED blinks with 250ms interval, Release Z-Wave button to try exclusion.c. DoorCam will try exclusion for 30sec.d. Z-Wave LED will be turned on if exclusion is successful. |
NIF |
XXXNIF |
Wakeup |
XXXWakeupDescription |
Protection |
XXXProtection |
FirmwareUpdate |
XXXFirmwareUpdate |
SetAssociation |
XXXSetAssociation |
Association Groups:
Group Number |
Maximum Nodes |
Description |
1 |
1 |
This product's Association Group are used by Life Line of products. |
Technical Data
Hardware Platform |
ZM5101 |
Device Type |
On/Off Power Switch |
Network Operation |
Listening Sleeping Slave |
Firmware Version |
HW: 1 FW: 39.58 |
Z-Wave Version |
6.61.00 |
Certification ID |
ZC10-17065651 |
Z-Wave Product Id |
0x023D.0x0043.0x0001 |
Firmware Updatable |
Updatable by Manufacturer |
Neutral Wire Required |
ok |
Color |
White |
Outdoor Use |
ok |
Sensors |
Motion/No Motion (Binary) |
Communications Connections |
None |
Frequency |
XXfrequency |
Maximum transmission power |
XXantenna |