This is a
To add the ZP3111 to the Z-Wave network (inclusion), place the Z-Wave primary controller into inclusion mode.Press the Program Switch of ZP3111 for sending the NIF. After sending NIF, Z-Wave will send the auto inclusion, otherwise, ZP3111 will go to sleep after 20 seconds.
* Includes Motion, Temperature, Humidity, and Light sensor* 360 degree detection (suitable for ceiling fixture)* Compact Size: 59*59*41mm* 2*AAA Battery* Low Battery Detection* LED Status Indicator* 100feet line of sight
Reset to factory default | Remove cover to trigged tamper switch, LED flash once & send out Alarm Report.Press Program Switch 10 times within 10 seconds, ZP3111 will send the Device Reset Locally Notification command and reset to the factory default. (Remark: This is to be used only in the case of primary controller being inoperable or otherwise unavailable.) |
Inclusion | To add the ZP3111 to the Z-Wave network (inclusion), place the Z-Wave primary controller into inclusion mode.Press the Program Switch of ZP3111 for sending the NIF. After sending NIF, Z-Wave will send the auto inclusion, otherwise, ZP3111 will go to sleep after 20 seconds. |
Exclusion | To remove the ZP3111 from the Z-Wave network (exclusion), place the Z-Wave primary controller into exclusion mode, and following its instruction to delete the ZP3111 to the controller.Press the Program Switch of ZP3111 once to be excluded. |
NIF | XXXNIF |
Wakeup | Use Wake Up command to set up the awaking time (from 10 minutes to 1 week) and send the wake up notification to controller |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | LifelineCOMMAND_CLASS_BASIC_SETCOMMAND_CLASS_BATTERY_REPORTCOMMAND_CLASS_DEVICE_RESET_LOCALLY_NOTIFICATIONCOMMAND_CLASS_NOTIFICATION_REPORTCOMMAND_CLASS_SENSOR_MULTILEVEL_V7 |
0x00 = C0x01 = F Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Choose F |
1~50 (Set up from 0.1C~5C) Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 50 | Auto Temperature Interval from 0.1C~5C |
1~50 (Set up from 1%~50%) Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 50 | Auto Humidity Report Interval from 1% ~ 50% |
0,5~50 (Set up from 0 for Off or 5%~50%) Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 50 | Auto Light Report Interval from off or 5%~50% |
1 ~ 255 (unsigned decimal) Minutes(default: 3 minutes) Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 255 | Motion Re-triggering Duration (in minute) |
1 ~ 7(default: 4) Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
1 - 7 | Motion Sensitivity |
1 ~ 3 (Mode 1 ~ Mode 3)Mode 1LED Turn Off (Both Temp./PIR Trigger)Mode 2Temp. (Breathing Light Mode)PIR (Quick Flash)Mode 3LED Quick Flash (Temp./PIR Trigger) Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 3 | LED Flash Mode Selection |
Hardware Platform | ZM5202 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 5 FW: 5.01:10.01 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-17075680 |
Z-Wave Product Id | 0x0109.0x2021.0x2101 |
Sensors | Motion/No Motion (Binary) |
Firmware Updatable | Updatable by Consumer by RF |
Communications Protocol | Z-Wave Z/IP |
Color | White |
Supported Notification Types | Access Control |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |