This is a
1. Press [SET] for 1 second2. Enter 4-8 digitsPrograming Code3. Press the buttons #90#4. Include successfully (beep * 1)
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Great ConvenienceTouch to activate, touch to lockConnect your Z-Wave smart home system and operate from anywhereHolds up to 25 user codesHolds up to 4 single-entry codesVacation mode (deactivates all user codes temporarily)Auto-lock with adjustable delay (10 - 99 seconds)Back-up mechanical keywayUncompromised SecurityANSI Grade 2 qualitydeadbolt operates over 150,000 timesANSI A156.25 compliant - resistant to dust, rain, and corrosion under variable temperatures4-digit random guiding code prevents code-probingTouch screen is temporarily disabled after 4 consecutive incorrect entriesEasy InstallationEasy installation with a Philips screwdriverFits most standard door preparationsOnline video instruction available (please scan the QR code on this box)
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
1. Remove one battery.2. Press and hold SET button while inserting the battery back. Hold the set button until long beep has finished.3. Resotring the lock to factory settings will remove its connection to your network and clear all devices from its assocation group. The reset procedure should only be used when the primary controller is missing or inoperable.4. Please re-enter the default Programming Code to set up the lock after restoring to factory settings.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline; A NOTIFICATION frame is sent to the nodes in this association group when a lifeline event occurs. |
Hardware Platform | ZM5202 |
Device Type | Door Lock - Keypad |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 255 FW: 1.66:01.01 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-17115848 |
Z-Wave Product Id | 0x0262.0x0004.0x0001 |
Door Lock Type | Deadbolt |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |