Quickstart

This is a Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
Inclusion: Including the RTH100Z into an Existing Network:1. Set your primary controller to Include mode, to add the RTH100Z as a node on your network (see your controllers user manual for detailed instructions).2. Press and release the Install button. The controller will indicate the device has been included into the network.Your controller will indicate the RTH100Z was successfully added to its network (see your controllers user manual for details).Inclusion and exclusion are always done at normal transmit power mode.If your controller supports NWI, then you can optionally set the primary to NWI include mode. Please note that NWI inclusion mode does not end when you have included a new node.This allows multiple nodes to be included without having to physically go back to the controller to initiate the next inclusion.Therefore you must manually terminate NWI inclusion mode at the controller when you have finished including any new nodes to the network.Since intermediate included nodes will assist the inclusion process by routing messages, we recommend that nodes close to the primary controller be installed first, proceeding out in consecutive rings from the controller.Note: Consult your controllers user manual for details on removing a device from a Z-Wave network.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Remote Temperature and Humidity Sensor for HVAC market

Reset to factory default Factory Reset To reset the RTH100Zs configurations and Z-Wave parameters to Factory Settings (Including association groups and scene configurations), and remove the RTH100Z from any Z-Wave network: Note: Please use this procedure only when the network primary controller is missing or otherwise inoperable1. Hold down the Install button for approximately 10 seconds 2. Release the install button (the RTH100Z will reset all internal configuration including z-wave configurations). The unit will then reset. 3. When the Status LED begins to blink (un-enrolled) the unit has finished restoring configurations is running in normal mode.
Inclusion Inclusion: Including the RTH100Z into an Existing Network:1. Set your primary controller to Include mode, to add the RTH100Z as a node on your network (see your controllers user manual for detailed instructions).2. Press and release the Install button. The controller will indicate the device has been included into the network.Your controller will indicate the RTH100Z was successfully added to its network (see your controllers user manual for details).Inclusion and exclusion are always done at normal transmit power mode.If your controller supports NWI, then you can optionally set the primary to NWI include mode. Please note that NWI inclusion mode does not end when you have included a new node.This allows multiple nodes to be included without having to physically go back to the controller to initiate the next inclusion.Therefore you must manually terminate NWI inclusion mode at the controller when you have finished including any new nodes to the network.Since intermediate included nodes will assist the inclusion process by routing messages, we recommend that nodes close to the primary controller be installed first, proceeding out in consecutive rings from the controller.Note: Consult your controllers user manual for details on removing a device from a Z-Wave network.
Exclusion Exclusion: Removing the RTH100Z from a Network:1. Set your primary controller to Remove mode, to remove the RTH100Z as a node on your network (see your controllers user manual for detailed instructions).2. Press and release the Install button. The controller will indicate the device has been removed from the network.3. The device will automatically be restored to its default settings
NIF XXXNIF
Wakeup To wake-up the device for configuration you can triple-press the install button.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus Lifeline
2 5 Temperature Reports
3 5 Humidity Reports
4 5 Temperature driven BASIC_SETs
5 5 Humidity driven BASIC_SETs
6 5 Battery Reports

Configuration Parameters

Parameter 1: Time between sending Battery Reports in Hours

Time between sending Battery Reports in Hours
Size: 1 Byte, Default Value: 0

Setting Description
1 - 127 1127 hours
0 Disabled

Parameter 10: Group2 Temperature Delta Autosend Threshold

Group2 Temperature Delta Autosend Threshold (how many degree change from the last autosend)
Size: 1 Byte, Default Value: 10

Setting Description
1 - 50 In tenths of degrees
0 Disabled

Parameter 11: Group2 Periodic Temperature Send Interval

Group2 Periodic Temperature Send Interval (minutes)
Size: 1 Byte, Default Value: 0

Setting Description
1 - 120 Minutes
0 Disabled

Parameter 12: Send Basic Set On above humidity

Send Basic Set On above humidity See also Register 20
Size: 1 Byte, Default Value: 0

Setting Description
0 - 100 Percent
0 Disabled

Parameter 13: Send Basic Set On below humidity

Send Basic Set On below humidity See also Register 20
Size: 1 Byte, Default Value: 0

Setting Description
0 - 100 Percent
0 Disabled

Parameter 14: Send Basic Set Off above humidity

Send Basic Set Off above humidity See also Register 20
Size: 1 Byte, Default Value: 0

Setting Description
0 - 100 Percent
0 Disabled

Parameter 15: Send Basic Set Off below humidity

Send Basic Set Off below humidity See also Register 20
Size: 1 Byte, Default Value: 0

Setting Description
0 - 100 Percent
0 Disabled

Parameter 16: Group1- Humidity Delta Autosend Threshold

Group1- Humidity Delta Autosend Threshold (how many degree change from the last autosend)
Size: 1 Byte, Default Value: 5

Setting Description
1 - 50 Percent

Parameter 17: Group1- Periodic Humidity Send Interval

Group1- Periodic Humidity Send Interval
Size: 1 Byte, Default Value: 0

Setting Description
1 - 120 Minutes
0 Disabled

Parameter 18: Group3- Humidity Delta Autosend Threshold

Group3- Humidity Delta Autosend Threshold (how many degree change from the last autosend)
Size: 1 Byte, Default Value: 5

Setting Description
1 - 30 Percent
0 Disabled

Parameter 19: Group3- Periodic Humidity Send Interval

Group3- Periodic Humidity Send Interval (minutes)
Size: 1 Byte, Default Value: 0

Setting Description
1 - 120 Minutes
0 Disabled

Parameter 2: Send Basic Set On above temp

Send Basic Set On above temp See also Register 20
Size: 1 Byte, Default Value: 121

Setting Description
15 - 120 15120 Degrees F
121 Disabled

Parameter 20: Basic Set Options for Temp and Humidity

Basic Set Options for Temp and Humidity
Size: 1 Byte, Default Value: 1

Setting Description
2 Enable Configuration Registers 2, 5, 13, 14
1 Enable Configuration Registers 2, 5, 12, 15
3 Enable Configuration Registers 3, 4, 12, 15
4 Enable Configuration Registers 3, 4, 13, 14

Parameter 21: Temp offset

Temp offset
Size: 1 Byte, Default Value: 0

Setting Description
249 - 7 Degrees(-7 to 7)

Parameter 22: Humidity offset

Humidity offset
Size: 1 Byte, Default Value: 0

Setting Description
249 - 7 Percent(-7 to 7)

Parameter 23: Humidity Filter Time Constant

Humidity Filter Time Constant
Size: 1 Byte, Default Value: 30

Setting Description
1 - 60 Minutes

Parameter 3: Send Basic Set On below temp

Send Basic Set On above temp See also Register 20
Size: 1 Byte, Default Value: 121

Setting Description
15 - 120 15120 Degrees F
121 Disabled

Parameter 4: Send Basic Set On below temp

Send Basic Set On below temp See also Register 20
Size: 1 Byte, Default Value: 121

Setting Description
15 - 120 15120 Degrees F
121 Disabled

Parameter 5: Send Basic Set Off below temp

Send Basic Set Off below temp See also Register 20
Size: 1 Byte, Default Value: 121

Setting Description
15 - 120 15120 Degrees F
121 Disabled

Parameter 6: Make multiple attempts for all Basic Set Commands

Make multiple attempts for all Basic Set Commands
Size: 1 Byte, Default Value: 0

Setting Description
1 - 5 Number of extra attempts sent every minute after first send
0 Disabled

Parameter 7: Temp Units

Temp Units
Size: 1 Byte, Default Value: 1

Setting Description
1 Fahrenheit
0 Celsius

Parameter 8: Group1 Temperature Delta Autosend Threshold

Group1 Temperature Delta Autosend Threshold (how many degree change from the last autosend)
Size: 1 Byte, Default Value: 10

Setting Description
1 - 200 In tenths of degrees

Parameter 9: Group1 Periodic Temperature Send Interval

Group1 Periodic Temperature Send Interval (minutes)
Size: 1 Byte, Default Value: 0

Setting Description
1 - 120 Temperature Send Interval (minutes)
0 Disabled

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 2 FW: 1.40
Z-Wave Version 6.51.07
Certification ID ZC10-17115888
Z-Wave Product Id 0x0010.0x5253.0x5433
Color White
Firmware Updatable Updatable by Consumer by RF
Sensors Air TemperatureHumidity
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoNotification Sensor