This is a
Put the Z-Wave controller into add modeEnter the Master code on the lock, followed by #Press the 4 button, followed by #Press the 1 button followed by #Refer to the operation manual of the Z-Wave controller to complete the add/inclusion processFor more information on this please visit:www.yale.co.uk/smart-living
Keyfree Connected Ready smart lockFeaturesBattery operatedLow battery indicator with emergency battery connectionUser codes and settings remain if batteries are replaced3 minute lock out if code is entered incorrectly 5 timesTamper alarmFor use on UPVC & Composite Doors2 year guarantee
Reset to factory default | Enter the Master code on the lock, followed by #Press the 4 button, followed by #Press the 0 button followed by #Please use this procedure only when the network controller is missing or inoperable |
Inclusion | Put the Z-Wave controller into add modeEnter the Master code on the lock, followed by #Press the 4 button, followed by #Press the 1 button followed by #Refer to the operation manual of the Z-Wave controller to complete the add/inclusion processFor more information on this please visit:www.yale.co.uk/smart-living |
Exclusion | Put the Z-Wave controller into remove modeEnter the Master code on the lock, followed by #Press the 4 button, followed by #Press the 2 button followed by #Refer to the operation manual of the Z-Wave controller to complete the remove/exclusion processFor more information on this please visit:www.yale.co.uk/smart-living |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
Volume of product during operation Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 | Silent |
2 | Low Volume |
3 | High Volume |
Auto relock On/Off Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 | Auto relock Off |
255 | Aut Relock On |
Amount of time lock is opened before it relocks, after it has been unlocked by PIN code, key cards or key tags Size: 1 Byte, Default Value: 7
Setting | Description |
---|---|
7 - 60 | Amount of time (secs) |
Amount of time lock is opened before it relocks, after it has been unlocked by Z-Wave hub Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
10 - 90 | Amount of time (secs) |
Hardware Platform | ZM5202 |
Device Type | Door Lock - Keypad |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 32 FW: 32.16:13.16 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-18015918 |
Z-Wave Product Id | 0x0129.0x0006.0x0001 |
IP (Ingress Protection) Rated | ok |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |