Quickstart

This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Oomi In-Wall Switch is a Z-Wave Smart Switch specifically used to enable Z-Wave command and control (on/off) of any wall switches. In the event of power failure, non-volatile memory retains all programmed information relating to the units operating status.It can connect to 2 external manual switches to control the load ON/OFF independently. Its surface has a pin socket, which can be used for connecting to the touch panel, so you can also use the touch panel to control the Dual Nano Switch.The In-Wall Switch is also a security Z-Wave device and supports Over The Air (OTA) feature for the products firmware upgrade.

Reset to factory default Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable.
Inclusion Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing.
Exclusion Turn the primary controller of Z-Wave network into exclusion mode, short press the products Action button that you can find on the product's housing.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline.When the load state of In-Wall Switch (turn on/off the load) is changed, the Hail CC and Basic Report (configured by parameter 80) can be sent to the associated nodes in this group.
2 5 Forward the Basic Set, Switch All, Scene Activation Set to associated nodes in Group 2 when the In-Wall Switch receives the Basic Set, Switch All, Scene Activation Set commands from main controller. (E.g. Send/forward Basic Set to control the other nodes in association Group 2)
3 5 Send Basic Set (configured by parameter 0x51 ) to the associated nodes in Group 3 when the external switch S1 is operated.Note: The Switch Mode of external switch S1 should be identified successfully, which means that the value of Configuration parameter 0x78 should be non-zero, then the Basic Set can be sent to the associated nodes in Group 3 via triggering the S1 switch.
4 5 Send Basic Set (configured by parameter 0x52) to the associated nodes in Group 4 when the external switch S2 is operated.Note: The Switch Mode of external switch S2 should be identified successfully, which means that the value of Configuration parameter 0x79 should be non-zero, then the Basic Set can be sent to the associated nodes in Group 3 via triggering the S2 switch.

Configuration Parameters

Parameter 120: Configure the external switch mode for S1.

Configure the external switch mode for S1.
Size: 1 Byte, Default Value: 0

Setting Description
2 3 way switch mode
0 Enter automatic identification mode
1 2-state switch mode
3 Momentary push button mode

Parameter 121: Configure the external switch mode for S2.

Configure the external switch mode for S2.
Size: 1 Byte, Default Value: 0

Setting Description
0 Enter automatic identification mode
1 2-state switch mode
2 3 way switch mode
3 Momentary push button mode

Parameter 122: Set the control destination for external switch

Set the control destination for external switch
Size: 1 Byte, Default Value: 3

Setting Description
1 control the output loads of itself.
2 control the other nodes
3 control the output loads of itself and other nodes.

Parameter 20: Configure the output status after re-power on it.

Configure the output status after re-power on it.
Size: 1 Byte, Default Value: 0

Setting Description
1 Always on
0 Last status
2 Always off

Parameter 252: Lock/unlock configuration parameters

Lock/unlock configuration parameters.
Size: 1 Byte, Default Value: 0

Setting Description
0 Unlock
1 Lock

Parameter 255: Reset the In-Wall Switch

Reset the In-Wall Switch to factory default.
Size: 4 Byte, Default Value: 0

Setting Description
1431655765 Reset to factory default setting and removed from the z-wave network
0 Reset all configuration parameters to factory default setting

Parameter 4: Overheat protection.

Output Load will be turned off automatically after 30 seconds and if the temperature of product inside exceeds 100 .
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable

Parameter 80: To set which notification would be sent to the associated devices (Group 1)

To set which notification would be sent to the associated devices (Group 1) when the state of Nano Dimmers load is changed.
Size: 1 Byte, Default Value: 3

Setting Description
0 Send Nothing
1 Send Hail CC
2 Send Basic Report CC
3 Send Hail CC when using the manual switch to change the load state.

Parameter 81: To set which notification would be sent to the associated nodes in association group 3

To set which notification would be sent to the associated nodes in association Group 3 when using the external switch 1 to switch the loads.
Size: 1 Byte, Default Value: 1

Setting Description
0 Send Nothing
1 Send Basic Set CC

Parameter 82: To set which notification would be sent to the associated nodes in association group 4

To set which notification would be sent to the associated nodes in association Group 4 when using the external switch 2 to switch the loads.
Size: 1 Byte, Default Value: 1

Setting Description
1 Send Basic Set CC
0 Send Nothing

Parameter 83: Configure the state of LED when it is in 3 modes

Configure the state of LED when it is in 3 modes (Energy mode, Momentary indicate mode, Night light mode)
Size: 1 Byte, Default Value: 0

Setting Description
0 Energy mode. The LED will follow the status (on/off).
1 Momentary indicate mode. When the state of Switchs load changed, the LED will follow the status (on/off) of its load, but the LED will turn off after 5 seconds if there is no any switch action.
2 Night light mode. The LED will remain ON state.

Parameter 84: Set the ON/OFF time of the LED when it is in Night light mode.

Set the ON/OFF time of the LED when it is in Night light mode.
Size: 4 Byte, Default Value: 301991936

Setting Description
0 - 60 The minute time of OFF
256 - 316 The hour time of OFF
65536 - 65596 The minute time of ON
16777216 - 16777276 The hour time of ON

Parameter 86: Set appointment 1

Set the ON time of output load.
Size: 4 Byte, Default Value: 8327680

Setting Description
0 - 60 The minute value of ON time
65536 - 65543 The day value (Mon to Sun)
16777216 Enable the setting.
256 - 316 The hour value of ON time
16777215 Disable the setting.

Parameter 87: Set appointment 2

Set the OFF time of output load.
Size: 4 Byte, Default Value: 8327680

Setting Description
256 - 316 The hour value of ON time
65536 - 65543 The day value (Mon to Sun)
16777215 Disable the setting.
0 - 60 The minute value of ON time
16777216 Enable the setting.

Technical Data

Hardware Platform ZM5101
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 139 FW: 1.01:01.00
Z-Wave Version 6.51.09
Certification ID ZC10-18015946
Z-Wave Product Id 0x016A.0x0203.0x008B
Z-Wave Scene Type Scene
Firmware Updatable Updatable by Consumer by RF
Electric Load Type Dimmable LEDELV (Electronic)FluorescentIncandescentLEDMLV (Magnetic)
Supported Notification Types Heat Alarm
Switch Type Toggle
Frequency XXfrequency
Maximum transmission power XXantenna
Australia / New ZealandOn/Off Power Switch