Quickstart

This is a Window Covering - Pos/End Aware for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Autoinclusion - This feature allow you to add hard to reach devices to Z-Wave network. 3-times ON and OFF the power roller shutter (OFF-ON-OFF-ON-OFF-ON) causes the introduction of roller shutter to Autoinclusion mode. Please note that the procedure has been started the time between on and off can not exceed 20s. Autoinclusion mode is activated for a maximum of 10 minutes. During this time, we can add an awning to any Z-Wave controller running in the Include procedure.Include - This function allow you to add roller shutter to the network Z-Wave. Follow the procedur adding device to the network Z-Wave according to user manual supplied with the product. Then, press the programming button P on the roller shutter for 1 second.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

FAKRO ARZ Z-Wave external roller shutters have been adapted for wireless cooperation with the Z-Wave system. The shutter is designed for FAKRO roof windows and its installation is possible at any time after roof window installation. It is also possible to use the shutter for roof windows of other manufactures. Installed on the outside of the window, the roller shutter constitutes an optimum solution against overheating and provides additional protection of the window e.g. against falling tree branches etc. The roller shutter enables complete blackout and good sound reduction. It is also good protection from glazing excessive cooling during the winter. The roller shutter also means increased security. It has built-in overload protection and can be controlled by using standard Z-Wave controller.The AMZ Z-Waveroller shutter has three extremes: - Maximum extension (encoder maximum position)- Completely rolled up (encoder minimum position)- Current limiting protecting awning blind against damage and user against accidental injury resulting from the contact with moving elements of awning blind.There are three association groups in roller shutter ARZ Z-Wave:1.Life Linegroup for position reporting roller shutter after each a stoppage and alarm reporting (overcurrent, damage encoders). This group can be a maximum 1 device.2.Basic Repeatgroup used to transfer the received basic commands to the devices included in this group. This group can be a maximum 5 devices.3.Multilevel Repeatgroup used to transfer the received multilevel commands to the devices included in this group. This group can be a maximum 5 devices.Technical Parameters: Power voltage: 15V DCRated current: 1,4 ACurrent limit: YESSpeed: 23 r.p.mTemperature of usage: (-10 C) do (65C) Supplying cable: 2 x 0,75mm2

Reset to factory default Device Reset LocallyThis function allows you to reset the Z-Wave network without the use of Z-Wave controller. Press 5 times the programming button P fast, the roller shutter was removed from the Z-Wave network, restore the default parameters, name and locations. Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Inclusion Autoinclusion - This feature allow you to add hard to reach devices to Z-Wave network. 3-times ON and OFF the power roller shutter (OFF-ON-OFF-ON-OFF-ON) causes the introduction of roller shutter to Autoinclusion mode. Please note that the procedure has been started the time between on and off can not exceed 20s. Autoinclusion mode is activated for a maximum of 10 minutes. During this time, we can add an awning to any Z-Wave controller running in the Include procedure.Include - This function allow you to add roller shutter to the network Z-Wave. Follow the procedur adding device to the network Z-Wave according to user manual supplied with the product. Then, press the programming button P on the roller shutter for 1 second.
Exclusion Exclude - This function allow you to remove roller shutter from the network Z-Wave. Follow the procedur removing device from the network Z-Wave according to user manual supplied with the product. Then, press the programming button P on the roller shutter for 1 second. Function removes information only about newtork Z-Wave.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus Lifeline, group for position reporting roller shutter after each a stoppage and alarm reporting (overcurrent, damage encoders)
2 5 Basic Repeatgroup used to transfer the received basic commands to the devices included in this group.
3 5 Multilevel Repeatgroup used to transfer the received multilevel commands to the devices included in this group.

Configuration Parameters

Parameter 12: Calibrate

Value describe the calibration status
Size: 1 Byte, Default Value: 1

Setting Description
1 - 2 Value 1calibrated, Value 2discalibratedto enter the calibration mode must first time discalibrate and then calibrate.

Parameter 13: End Position

Value describe the end position of roller shutter.
Size: 1 Byte, Default Value: 1

Setting Description
1 - 2 1FF go to Max, 2FF go to previous position

Technical Data

Hardware Platform ZM5202
Device Type Window Covering - Pos/End Aware
Network Operation Always On Slave
Firmware Version HW: 23 FW: 1.01:01.01
Z-Wave Version 6.61.00
Certification ID ZC10-18015975
Z-Wave Product Id 0x0085.0x0003.0x0011
Switch Type Push Button with Indicator
Window Covering Control Features Endpoint AwareManual CalibrationPosition AwareSupports Open/Close MotionSupports Up/Down Motion
Supported Notification Types Power ManagementSystem
Outdoor Use ok
Frequency XXfrequency
Maximum transmission power XXantenna