Quickstart

This is a Light Dimmer Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
When the pushbutton is released after a press of (2sec



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Simon iO Dimmer is ready to operate with Z-Wave controllers and configured to be managed by Simon100 IO APP using the HUB plug IO for getting a better user experience. Sending the Blind Up/Down or setting a specific position.

Reset to factory default When the pushbutton is released after a press of (30sec
Inclusion When the pushbutton is released after a press of (2sec
Exclusion When the pushbutton is released after a press of (2sec
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 3 Z-Wave Plus Lifeline
2 20 ctrl.CC Basic, Basic Report, Value 0x00 - 0x63 Report Dimming vaule after 2 seconds of last dimming change.

Configuration Parameters

Parameter 1: Association LED

Activates the Central LED. Configuration Used by Masters iO in order to identify the devices associated to their Group2 during manual association process.
Size: 1 Byte, Default Value: 0

Setting Description
0 Turns the LED OFF
1 - 255 Turns the LED ON

Parameter 10: Delay ON

Time that Dimmer delays the activation of the load after it receives an ON request.This value must be set in hexadecimal format, and can accept these values:0 --> ON Delay is 0.0x01...0x7F --> Delay ON is from 1 to 127 seconds. (1 second resolution)0x80...0xfE--> Delay ON is from 1 to 127 seconds. (1 minute resolution)
Size: 1 Byte, Default Value: 0

Setting Description
0 ON Delay is 0 seconds
1 - 127 ON Delay is set in seconds from 1 to 127 seconds
128 - 254 ON Delay is set in minutes from 1 to 127 minutes

Parameter 11: Activation Time

Time that Dimmer activates of the load after it turns the load ON.This value must be set in hexadecimal format, and can accept these values:0 --> Activation Time is 0.0x01...0x7F --> Activation Time is from 1 to 127 seconds. (1 second resolution)0x80...0xfE--> Activation Time is from 1 to 127 seconds. (1 minute resolution)
Size: 1 Byte, Default Value: 0

Setting Description
0 Activation Time is 0 seconds
1 - 127 Activation Time is set in seconds from 1 to 127 seconds
128 - 154 Activation Time is set in minutes from 1 to 127 minutes

Parameter 12: Behavior of LED in Repose

Sets the Left and Right Leds to 20% in order to find the device and the touch areas at night.
Size: 1 Byte, Default Value: 0

Setting Description
0 Left and Right LEDs OFF
1 - 255 Left and Right LEDs ON at 20percent

Parameter 13: Lock Input

Locks the local control of the sunblind. This configuration does not modifies the control via Z-Wave.
Size: 1 Byte, Default Value: 0

Setting Description
0 Local action enabled
1 - 255 Local action locked

Parameter 15: Reset Default

Write only parameter used to restore configurations or perform a completely restore default.
Size: 2 Byte, Default Value: 0

Setting Description
17170 Configuration values are restored
39015 Factory reset.

Parameter 16: Delay OFF

Time that Dimmer delays the deactivation of the load after it receives an OFF request.This value must be set in hexadecimal format, and can accept these values:0 --> Delay OFF is 0.0x01...0x7F --> Delay OFF is from 1 to 127 seconds. (1 second resolution)0x80...0xfE--> Delay OFF is from 1 to 127 seconds. (1 minute resolution)
Size: 1 Byte, Default Value: 0

Setting Description
0 OFF Delay is 0 seconds
1 - 127 OFF Delay
128 - 254 OFF Delay is set in minutes from 1 to 127 minutes

Parameter 19: Press Action

Defines the action to be performed when key is pressed.
Size: 1 Byte, Default Value: 5

Setting Description
0 When short press, the device toggles the load. The Slider does not work.
1 When short press, the device turns ON the load. The Slider does not work.
2 When short press, the device turns OFF the load. The Slider does not works.
4 When short press, the device turns ON the load. When hold press from 2seconds to 10seconds device turns OFF the load. The Slider does not works with this configuration, the device will not send the Node Info neither Show the LEDs feedback with this press action. The Slider does not work.
5 When short press, the device toggles the load. The Slider dims the load when it is ON.

Parameter 20: Identify

Write only value that performs a fast blink on Central LED during 5 seconds in order to identify the device when it is installed in a multiple frame.
Size: 1 Byte, Default Value: 0

Setting Description
1 - 255 Central LED performs a fast blink

Parameter 21: Load State

Read only 2 Byte configuration parameter used to read the dimmer state.Byte 0 is used to know the load state ON or OFF.0 Dimmer is OFF.1 Dimmer is ON.Byte 1 is used to Know the last active dimming percentage.
Size: 2 Byte, Default Value: 0

Setting Description
1 - 99 Load is OFF and las timming value is from 1% to 99%
256 - 355 Load is ON Dimmed at 1% to 99%

Parameter 23: Calibration Required

Read only configuration used to know is device needs to be calibrated in order to work properly.
Size: 1 Byte, Default Value: 0

Setting Description
0 Device is calibrated
255 Calibration must be performed

Parameter 27: Lock Hold Press

Locks the major part of Hold press effects in order to avoid undesired callibrations, Z-Wave changes or restores Default.0xFF Hold Press from 2sec to 20 sec does not performs a Node infoHold Press of 10 to 15 does not performs a automatic callibrationHold press of 15 to 30 does not changes the sunblind or awing reportsHold press of 30sec restores configuration except Lock Hold Press, and sends a Node info in order to add or remove from Z-Wave Network
Size: 1 Byte, Default Value: 0

Setting Description
0 Hold Press is available
1 - 255 Hold Press from 2sec to 20 sec does not performs a Node info,Hold Press of 10 to 15 does not performs a automatic callibration,Hold press of 15 to 30 does not changes the sunblind or awing changes, Hold press of 30sec restores configuration except Lock Hold Press, and sends a Node info in order to add or remove from Z-Wave Network

Parameter 4: Set Time

Sets the u0022Set Timeu0022 that will take the Dimmer to go from 0% to 100%This value must be set in hexadecimal format, and can accept these values:0 --> Set Time is 0.0x01...0x7F --> Set Time is from 1 to 127 seconds. (1 second resolution)0x80...0xfE--> Set Time is from 1 to 127 seconds. (1 minute resolution)
Size: 1 Byte, Default Value: 0

Setting Description
0 Sets Time is 0
1 - 127 Set Time is set in seconds from 1 to 127 minutes
128 - 254 Set Time is set in minutes from 1 to 127 minutes

Parameter 5: Fade Time

Sets the u0022Fade Timeu0022 that will take the Dimmer to go from 100% to 0%This value must be set in hexadecimal format, and can accept these values:0 --> Fade Time is 0.0x01...0x7F --> Fade Time is from 1 to 127 seconds. (1 second resolution)0x80...0xfE--> Fade Time is from 1 to 127 seconds. (1 minute resolution)
Size: 1 Byte, Default Value: 0

Setting Description
0 Fade Time is 0 seconds
1 - 127 Fade Time is set in seconds from 1 to 127 seconds
128 - 254 Fade Time is set in minutes from 1 to 127 minutes

Parameter 6: Min Dimming %

Relative adjust used to set the minimum regulation value. This adjust is done in reference to internal values, accepted dimming values will always be from 1 to 0x63.Minimum Value must be < than Maximum Value.
Size: 1 Byte, Default Value: 1

Setting Description
1 - 98 minimum internal dimming value

Parameter 7: Max Dimming %

Relative adjust used to set the maximum regulation value. This adjust is done in reference to internal values, accepted dimming values will always be from 1 to 0x63.Maximum Value must be > then Minimum Value.
Size: 1 Byte, Default Value: 100

Setting Description
2 - 99 maximum internal dimming value

Parameter 9: Callibration

Write only configuration used to request the automatic adjust of UP and DOWN times.
Size: 1 Byte, Default Value: 0

Setting Description
255 Sunblind starts its callibration process

Technical Data

Hardware Platform ZM5202
Device Type Light Dimmer Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 4.24:78.59:70.48
Z-Wave Version 6.51.07
Certification ID ZC10-18026010
Z-Wave Product Id 0x0267.0x0007.0x0000
Neutral Wire Required ok
Supported Meter Type Electric Energy
Electric Load Type Dimmable ELV (Magnetic)Dimmable LEDDimmable MLV (Magnetic)Incandescent
Firmware Updatable Updatable by Professional/Technician
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Light Dimmer Switch