This is a
1. Enter the 4-8 digit master PIN code followed by the gear key.2. Press the 7 key followed by the gear key.3. Press the 1 key followed by the gear key.
Yale Assure Lock is a secure, keyless lock developed by Yale exclusively available with Andersen Patio Doors (E-Series and A-Series hinged patio doors). Monitor, lock and unlock from anywhere with your Yale Assure Lock featuring Andersens VeriLock sensor technology and with Z-Wave integrate into a compatible home automation or security system. Includes Bluetooth technology for keyless unlocking.
Reset to factory default | Please use this procedure only when the network primary controller is missing or otherwise inoperable.When resetting the lock, all user codes,including the Master code*, are deleted. All programming features are reset to the original default settings.1. Remove the battery cover and batteries.2. Remove the interior lock to access the reset button.3. The reset button is located above the cable connectors. PCB4. Re-insert 3 batteries and hold the reset button for 3 seconds.5. While still holding the reset button, insert the 4th battery, and hold the reset button for an additional 3 seconds.6. Release the reset button.7. Re-install the interior lock onto the door.Upon reset, Master Code creation is the PIN only option available and must be performed prior to any other programming of the lock. For best results, the lock should be installed on the door when resetting the lock to factory default. If the process was done and the lock was not installed on the door, review the Re-Handing instructions listed in Hardware Troubleshooting. |
Inclusion | 1. Enter the 4-8 digit master PIN code followed by the gear key.2. Press the 7 key followed by the gear key.3. Press the 1 key followed by the gear key. |
Exclusion | 1. Enter the 4-8 digit master PIN code followed by the gear key.2. Press the 7 key followed by the gear key.3. Press the 3 key followed by the gear key. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
Level control, 1, 2, 3 default is 1. Levels are 1 and 3 for models with no spoken prompts default is 1 or high Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 3 | Level |
0x00 = OFF, 0xFF = ON default is 0xFF or ON. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 | One Touch Locking On |
0 | One Touch Locking Off |
0x00 = OFF, 0xFF = ON default is 0x00 or OFF Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 | Privacy Button On |
0 | Privacy Button Off |
01 = Lock will execute Reset To Factory.02 = Reserved for future use (Lock will currently execute Reset To Factory same as 01). No default valuePlease use this procedure only when the network primary controller is missing or otherwise inoperable Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 | Reset to Factory On |
0 | Reset to Factory Off |
10 to 127 second.This value is represented as seconds X 10. (ie a value of 4 would mean a door propped timer of 40 seconds) Set to 0x00 to disable Door Propped Alarm.Default = 0x00 (off) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
20 - 127 | Seconds |
0x00 = OFF, 0xFF = ON Default is 0x00 or off.Used to enable/disable door condition alarms for locks that support a door position sensor.Any lock that does not support DPS will always report 0x00. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 | DPS Alarm On |
0 | DPS Alarm Off |
0x00 = OFF, 0xFF = ON default is 0x00 or OFF Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 | Auto Relock On |
0 | Auto Relock Off |
10 to 180 seconds default is 5 seconds Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
10 - 127 | Seconds |
3 to 10 default is 5 times Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
3 - 10 | Times |
Set the lock language. Default is 1= English Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | English Language |
2 | Spanish Language |
3 | French Language |
10 to 127 seconds default is 60 seconds Size: 1 Byte, Default Value: 60
Setting | Description |
---|---|
10 - 127 | Seconds |
This sets the operating mode for the lock. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Normal Mode (Default) |
1 | Vacation Mode (Keypad Locked Out) |
2 | Privacy Mode (Keypad Locked, RF Unlock Functional) |
Hardware Platform | ZM5101 |
Device Type | Door Lock - Keypad |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 255 FW: 1.78:29.00 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-18056103 |
Z-Wave Product Id | 0x0129.0x8014.0x1604 |
Sensors | Open/Closed (Binary) |
Outdoor Use | ok |
Supported Notification Types | Access ControlPower Management |
Firmware Updatable | Updatable by Consumer by RF |
Door Lock Type | Deadbolt Motor Attachment |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |