Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
AUTO-INCLUSION:Initiate inclusion in the Z-Wave interface. Activating the battery will automatically put the sensor into inclusion mode. If its not added within 30 seconds, try resetting it and including it manually.MANUAL INCLUSION:1. Bring the sensor within direct range of your Z-Wave gateway (hub).2. Put the Z-Wave hub into inclusion mode.3. Press and release the Z-Wave button 3 times quickly. The LED indicator will start blinking fast and turn solid for a second to confirm inclusion.3. A new motion sensor will appear in your device list.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

PRODUCT FEATURES:- Fast, reliable motion detection- Built-in vibration sensor- Latest S2 security protocol and AES-128 signal encryption- 2 alternative power sources: battery or micro USB- Auto-inclusion for instant set-up- Visual range test tool- Magnetic mount for quick and flexible installation- Adjustable LED indicator- Low battery alerts- Z-Wave Plus with improved 500 chip for faster and safer wirelesscommunication

Reset to factory default If your primary controller is missing or inoperable, you may need to reset the device to factory settings.To complete the reset process manually, press and HOLD the Z-Wave button on the sensor for at least 20 seconds. The LED indicator will flash, stay solid, and then turn off to confirm factory reset.NOTE: All previously recorded activity and custom settings will be erased from the devices memory.
Inclusion AUTO-INCLUSION:Initiate inclusion in the Z-Wave interface. Activating the battery will automatically put the sensor into inclusion mode. If its not added within 30 seconds, try resetting it and including it manually.MANUAL INCLUSION:1. Bring the sensor within direct range of your Z-Wave gateway (hub).2. Put the Z-Wave hub into inclusion mode.3. Press and release the Z-Wave button 3 times quickly. The LED indicator will start blinking fast and turn solid for a second to confirm inclusion.3. A new motion sensor will appear in your device list.
Exclusion 1. Bring the sensor within direct range of your Z-Wave gatewaycontroller (hub).2. Put the Z-Wave hub into exclusion mode.3. Press and release the Z-Wave button on the sensor 3 times asquickly as possible.4. Your hub will confirm exclusion and the device will disappearfrom your controller's device list.
NIF XXXNIF
Wakeup MANUAL WAKE-UPPress and HOLD the Z-Wave button for 5 seconds to wake the deviceup. The LED will start flashing.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline
2 5 Basic Set

Configuration Parameters

Parameter 12: PIR Sensitivity

Use it to adjust PIR sensor sensitivity.
Size: 1 Byte, Default Value: 4

Setting Description
1 - 8 1 = low sensitivity and 8 = high sensitivity

Parameter 14: BASIC SET for Group 2

Use it to enable or disable BASIC SET reports when motion is triggered for Group 2 of associated devices.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disabled
1 Enabled

Parameter 15: BASIC SET for Group 2 Reversed Values

Use it to reverse values sent in BASIC SET reports when motion is triggered for Group 2 of associated devices.
Size: 1 Byte, Default Value: 0

Setting Description
0 BASIC SET value 255 is sent when motion is triggered, BASIC SET value 0 is sent when motion times out
1 BASIC SET value 0 is sent when motion is triggered, BASIC SET value 255 is sent when motion times out.

Parameter 17: Vibration Sensor

Use it to disable the vibration sensor.
Size: 1 Byte, Default Value: 1

Setting Description
0 vibration sensor is disabled
1 vibration sensor is enabled

Parameter 18: Motion Retrigger Interval

Use it to set trigger interval - the time when motion is reported again after initial trigger.
Size: 2 Byte, Default Value: 27

Setting Description
3 - 65535 3 stands for 6 seconds and 65535 stands for 65538 seconds (add 3 seconds to each value number).

Parameter 20: LED Indicator

Use it to disable the LED indicator.
Size: 1 Byte, Default Value: 1

Setting Description
0 LED Indicator is disabled
1 LED Indicator is enabled

Parameter 32: Low Battery Reports

Use it to set battery level for low battery reports.
Size: 1 Byte, Default Value: 10

Setting Description
10 - 50 10 stands for 10% battery left and 50 stands for 50% battery left

Technical Data

Hardware Platform ZM5101
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 1 FW: 1.00
Z-Wave Version 6.71.01
Certification ID ZC10-18066135
Z-Wave Product Id 0x027A.0x0201.0x0006
Supported Notification Types Home Security
Color White
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoNotification Sensor