Quickstart

This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
To add the product to the Z-Wave network:a. Make sure that the Smart Plug has been connected to the power supply.b. Set the Z-Wave network main controller into inclusion mode.c. Power on.d. The LED will blink fast until the inclusion is completed and then the LED will keep turning on or off. Otherwise, the LED will still blink slowly, in which you need to repeat the process from step b



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Flexibility: AC output on/off by manual or remote by APP Remote Control: Power on/off any device connecting to smart plug manually or by APP Power consumption: Measures the energy consumption of the connected devices. Schedule: setting your lights connected to Plug to turn on and off on a schedule. Z-wave Wireless signal repeater

Reset to factory default Reset Smart Plug to factory default:1. Make sure that the Smart Plug has been connected to the power supply.2. Press and hold the Button for 5 seconds.3. If holding time is more than one second, the LED will blink faster and faster. If holding time is more than 5 seconds, the LED will be solid for 3 seconds to indicate that the resetting is successful. Otherwise, repeat step 2.Note:Reset to factory will remove Smart Plug from the Z-Wave network. Use this procedure only in the event that the network primary controller missing or otherwise inoperable.
Inclusion To add the product to the Z-Wave network:a. Make sure that the Smart Plug has been connected to the power supply.b. Set the Z-Wave network main controller into inclusion mode.c. Power on.d. The LED will blink fast until the inclusion is completed and then the LED will keep turning on or off. Otherwise, the LED will still blink slowly, in which you need to repeat the process from step b
Exclusion To remove the product from the Z-Wave network:a. Insert the Smart Plug to power socket, the LED will follow the status (on or off) of its loads power level.b. Set the Z-Wave network main controller into exclusion mode.c. Short press Button 3 times within 1.5 second.d. The LED will blink fast until the exclusion is completed, then the LED will keep on blinking slowly. Otherwise, the LED will keep on blink fast for 35 seconds and then follow the status (on or off) of its load status.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 1. When the state of Smart Plug (turn on or off the load) is changed: 1. Set Configuration parameter 0x03 to 0: Do not send Basic Report 2. Set Configuration parameter 0x03 to 1: Send Basic Report 3. Set Configuration parameter 0x03 to 2: Send Basic Report only when Load condition is changed not by Z-WAVE Command, such as short pressing. 2. Sending Meter Report.

Configuration Parameters

Parameter 1: Overcurrent protection

Smart Plug keep detecting the load power, once the AC current exceeds 16.5A for more than 4 seconds, smart plug's relay will turn off.
Size: 1 Byte, Default Value: 1

Setting Description
0 The function is disabled
1 The function is enabled

Parameter 100: Setting the parameters 101~104 to the default states.

Setting the parameters 101~104 to the default states.
Size: 1 Byte, Default Value: 85

Setting Description
85 Available settings

Parameter 101: Setting time for sending meter report (watt)

The interval time of sending meter report (watt) to associated device (Group Lifeline).
Size: 4 Byte, Default Value: 600

Setting Description
5 - 2678400 Available settings
0 The function is disabled.

Parameter 102: Setting time for sending meter report (KWh)

The interval of sending meter report (KWh) to association device (Group Lifeline).
Size: 4 Byte, Default Value: 3600

Setting Description
5 - 2678400 Available settings
0 The function is disabled

Parameter 103: Setting time for sending meter report (voltage)

The interval of sending meter report (voltage) to association device (Group Lifeline).
Size: 4 Byte, Default Value: 0

Setting Description
5 - 2678400 Available settings
0 The function is disabled

Parameter 104: Setting time for sending meter report (current)

The interval time of sending meter report (current) to associated device (Group Lifeline).
Size: 4 Byte, Default Value: 0

Setting Description
5 - 2678400 Available settings
0 The function is disabled

Parameter 16: The value here represents minimum change in wattage (in terms of wattage) for a meter report to be sent

When the change value of load power exceeds the setting value, smart plug will send meter report (watt) to associated device (Group Lifeline).
Size: 2 Byte, Default Value: 50

Setting Description
-32768 - 32767 Available settings
-32768 - -1 65535 to 32768
1 - 32767 1 to 32767
0 The function is disabled.

Parameter 17: The value here represents minimum change in wattage percent (in terms of percentage) for a meter report (watt) to be sent

When the change value of the load power exceeds the setting value, smart plug will send meter report to associated device (Group Lifeline).
Size: 1 Byte, Default Value: 10

Setting Description
-128 - 127 Available settings
-128 - -1 255% to 128%
1 - 127 1% to 127%
0 The function is disabled

Parameter 2: Setting device status after power failure

Define how the Plug reacts after the power supply is back on.
Size: 1 Byte, Default Value: 1

Setting Description
0 Smart Plug memorizes its state after a power failure.
1 Smart Plug does not memorize its state after a power failure. Connected device will be on after the power supply is reconnected.
2 Smart Plug does not memorize its state after a power failure. Connected device will be off after the power supply is reconnected.

Parameter 254: Enable/disable the configuration command

Lock/unlock all configuration parameters.
Size: 1 Byte, Default Value: 0

Setting Description
0 Unlock
1 Lock

Parameter 3: Notification when Load status change

Smart Plug can send notifications to associated device (Group Lifeline) when the status of smart plugs load is changed.
Size: 1 Byte, Default Value: 1

Setting Description
0 The LED status follows the load change.
1 when operating the load, The LED lights for 5 seconds and then turns off.

Parameter 4: LED Load indicator mode selection

Configure LED Display mode to prevent light pollution at night.
Size: 1 Byte, Default Value: 0

Setting Description
0 The LED status follows the load change.
1 when operating the load, The LED lights for 5 seconds and then turns off.

Technical Data

Hardware Platform ZM5101
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.00
Z-Wave Version 6.71.01
Certification ID ZC10-18076185
Z-Wave Product Id 0x0384.0x0200.0x000B
Firmware Updatable Updatable by Consumer by RF
Switch Type Push Button
Z-Wave Scene Type Scene
Supported Meter Type Electric Energy
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoOn/Off Power Switch