This is a
To add the product to the Z-Wave network:a. Make sure that the Smart Plug has been connected to the power supply.b. Set the Z-Wave network main controller into inclusion mode.c. Power on.d. The LED will blink fast until the inclusion is completed and then the LED will keep turning on or off. Otherwise, the LED will still blink slowly, in which you need to repeat the process from step b
Flexibility: AC output on/off by manual or remote by APP Remote Control: Power on/off any device connecting to smart plug manually or by APP Power consumption: Measures the energy consumption of the connected devices. Schedule: setting your lights connected to Plug to turn on and off on a schedule. Z-wave Wireless signal repeater
Reset to factory default | Reset Smart Plug to factory default:1. Make sure that the Smart Plug has been connected to the power supply.2. Press and hold the Button for 5 seconds.3. If holding time is more than one second, the LED will blink faster and faster. If holding time is more than 5 seconds, the LED will be solid for 3 seconds to indicate that the resetting is successful. Otherwise, repeat step 2.Note:Reset to factory will remove Smart Plug from the Z-Wave network. Use this procedure only in the event that the network primary controller missing or otherwise inoperable. |
Inclusion | To add the product to the Z-Wave network:a. Make sure that the Smart Plug has been connected to the power supply.b. Set the Z-Wave network main controller into inclusion mode.c. Power on.d. The LED will blink fast until the inclusion is completed and then the LED will keep turning on or off. Otherwise, the LED will still blink slowly, in which you need to repeat the process from step b |
Exclusion | To remove the product from the Z-Wave network:a. Insert the Smart Plug to power socket, the LED will follow the status (on or off) of its loads power level.b. Set the Z-Wave network main controller into exclusion mode.c. Short press Button 3 times within 1.5 second.d. The LED will blink fast until the exclusion is completed, then the LED will keep on blinking slowly. Otherwise, the LED will keep on blink fast for 35 seconds and then follow the status (on or off) of its load status. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | 1. When the state of Smart Plug (turn on or off the load) is changed: 1. Set Configuration parameter 0x03 to 0: Do not send Basic Report 2. Set Configuration parameter 0x03 to 1: Send Basic Report 3. Set Configuration parameter 0x03 to 2: Send Basic Report only when Load condition is changed not by Z-WAVE Command, such as short pressing. 2. Sending Meter Report. |
Smart Plug keep detecting the load power, once the AC current exceeds 16.5A for more than 4 seconds, smart plug's relay will turn off. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | The function is disabled |
1 | The function is enabled |
Setting the parameters 101~104 to the default states. Size: 1 Byte, Default Value: 85
Setting | Description |
---|---|
85 | Available settings |
The interval time of sending meter report (watt) to associated device (Group Lifeline). Size: 4 Byte, Default Value: 600
Setting | Description |
---|---|
5 - 2678400 | Available settings |
0 | The function is disabled. |
The interval of sending meter report (KWh) to association device (Group Lifeline). Size: 4 Byte, Default Value: 3600
Setting | Description |
---|---|
5 - 2678400 | Available settings |
0 | The function is disabled |
The interval of sending meter report (voltage) to association device (Group Lifeline). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
5 - 2678400 | Available settings |
0 | The function is disabled |
The interval time of sending meter report (current) to associated device (Group Lifeline). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
5 - 2678400 | Available settings |
0 | The function is disabled |
When the change value of load power exceeds the setting value, smart plug will send meter report (watt) to associated device (Group Lifeline). Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
-32768 - 32767 | Available settings |
-32768 - -1 | 65535 to 32768 |
1 - 32767 | 1 to 32767 |
0 | The function is disabled. |
When the change value of the load power exceeds the setting value, smart plug will send meter report to associated device (Group Lifeline). Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
-128 - 127 | Available settings |
-128 - -1 | 255% to 128% |
1 - 127 | 1% to 127% |
0 | The function is disabled |
Define how the Plug reacts after the power supply is back on. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Smart Plug memorizes its state after a power failure. |
1 | Smart Plug does not memorize its state after a power failure. Connected device will be on after the power supply is reconnected. |
2 | Smart Plug does not memorize its state after a power failure. Connected device will be off after the power supply is reconnected. |
Lock/unlock all configuration parameters. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Unlock |
1 | Lock |
Smart Plug can send notifications to associated device (Group Lifeline) when the status of smart plugs load is changed. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | The LED status follows the load change. |
1 | when operating the load, The LED lights for 5 seconds and then turns off. |
Configure LED Display mode to prevent light pollution at night. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The LED status follows the load change. |
1 | when operating the load, The LED lights for 5 seconds and then turns off. |
Hardware Platform | ZM5101 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-18076185 |
Z-Wave Product Id | 0x0384.0x0200.0x000B |
Firmware Updatable | Updatable by Consumer by RF |
Switch Type | Push Button |
Z-Wave Scene Type | Scene |
Supported Meter Type | Electric Energy |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |