Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. - Press the Net_Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second. 
- If Inclusion Process is successful, Green led will turn off.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The Smart Smoke Alarm adopts Z-Wave protocol, when the sensor detects smoke to the set level, it will issueacoustic-optic alarm to alert the users and also send alarm notifications to gateway immediately.It‘s suitable to be installed in living room, office,warehouse,and etc.

Installation

- Flat ceiling mounting

The preferred location to install smoke sensor is in the centre of the ceiling, because smoke,  heat and combusible products rise to ceiling and will laterally spread. Keep at least 30 cm distance  from lights or decoration and at least 17cm away from walls and corners.

- Sloping ceiling mounting

If ceiling is sloping, please install the smok sensor at horizontal distance 90 cm away from the ceiling top.


Installation guide

 
- Anticlockwise rotation the bracket out from the installation base.



- Fixed the bracket intoceiling using srews.
- Remove the double-sided adhersive and stickalarm into ceiling


- Remove the battery insulating strip to make detector on power and clockwise rotating alarm into bracket.

Product Usage


Reset to factory default - Long press Net-Button while installing batteries in HS1SA-Z. 
- Device Reset Locally notification is Transmitted.
Inclusion - Press the Net-Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second.
- If Inclusion Process is successful, Green led will turn off.
Exclusion - Press the Net_Button 3 times within 1.5s 
- If Exclusion Process is successful, Green led is Blinking 6 times, then turn off.
NIF Press network button once.
Wakeup -Wake up Notification is transmitted every 24 hours by default.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 This is Lifeline association group, Including command classes: Battery report, Notification report, and Device Reset Locally notification
2 5 This is Root Device group,The Sensor sends a Basic Set command to directly trigger devices (like a light, switch, etc.) in response to events. The value of the Basic Set command (e.g. Siren trigger) is configured usingsmoke or no smoke.

Technical Data

Dimensions d= 48 x 52 mm
Weight 51 gr
Hardware Platform ZM5202
EAN 6971348970444
IP Class IP 20
Voltage 3V
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Z-Wave Version 6.71.03
Certification ID ZC10-18076198
Z-Wave Product Id 0x0260.0x8002.0x1000
Firmware Updatable Updatable by Manufacturer
Supported Notification Types Emergency AlarmSmoke Alarm
Color White
Communications Protocol Z-Wave Serial API
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeNotification Sensor