Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
To add the unit to the network, put the controller (purchased separately) into the pairing/add/inclusion mode and then press and hold the inclusion/exclusion button on the side of the detector for at least 5 seconds.The blue light will begin to flash to indicate its in the pairing mode.When the blue light goes solid, the unit has been included in the network.If the blue light is not illuminated, the unit is not part of a network



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The advanced version of the micro-resonator methane detector with wireless capabilities. The wireless capability means that when methane is detected in one residence/facility location all other detectors in the same network are alerted so that the facility can be evacuated. Conforms to UL 1484

Reset to factory default This device will perform a Z-Wave factory reset when the exclusion process stated above is followed.Please use this procedure only when the network primary controller is missing or otherwise inoperable
Inclusion To add the unit to the network, put the controller (purchased separately) into the pairing/add/inclusion mode and then press and hold the inclusion/exclusion button on the side of the detector for at least 5 seconds.The blue light will begin to flash to indicate its in the pairing mode.When the blue light goes solid, the unit has been included in the network.If the blue light is not illuminated, the unit is not part of a network
Exclusion To remove the unit from a network put the controller (purchased separately) into the pairing/removal/exclusion mode and then press and hold the inclusion/exclusion button on the side of the detector for at least 5 seconds.The blue light will begin to flash and will go out when the device is removed from the network
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 16 Z-Wave Plus LifelineCombustible Gas Notification message when methane is detected
2 16 Combustible Gas Notification message when methane is detected

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Always On Slave
Firmware Version HW: 1 FW: 6.01:01.05:01.04
Z-Wave Version 6.81.01
Certification ID ZC10-18086211
Z-Wave Product Id 0x038E.0x0001.0x0001
Supported Notification Types Gas Alarm
Communications Protocol Z-Wave Serial API
Color White
Sensors Methane Density
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoNotification Sensor