1. To include this device in a Z-Wave network, select the command on your Z Wave controller for inclusion (Install, Add Device,Add Node, Include Device, etc.). Then press the device ON/OFF button one time to include it in the network.2. Based on the controller, the controller may ask you to scan the QR code or manually enter 5 digit code under the QR codeto install the device as a secured device. You may find this QR code on the device or included in device packaging.3. After the Device is added to the network, the blue indicator LED will stop blinking. This indicates the device is installed in the Z-Wavenetwork.
Eatons Z-Wave Accessory Switch can be used with Eaton's RF9601 switch & other Z-Wave Plus certified devices to provide 3-way, multi-location ON/OFF control of a selected Z-Wave wireless switch without the need for traditional 3-way wiring. You can use your compatible Z-Wave certified controller to associate each accessory with up to (5) other Z-Wave load controlling devices. Features & Benefits: Wireless accessory for Eatons Z-Wave Wireless Switch (RF9601) Ideal for applications where no traveler wires exist for 3-Way & multi-location control Neutral is required for installationSupports Z-Wave Plus technology including S2 Security certification for advanced encryption & cybersecurity Can be associated with (5) other Z-Wave Plus devices when used with a compatible Z-Wave controller
Reset to factory default | Please use this procedure only when the network primary controller is missing or otherwise inoperable.The device could be reset locally. This will cause the device to be excluded from its network and restore to factory default.Before leaving the network the switch will send a notification to the controller indicating its departure from the Z-Wave network.1. Turn the device ON.2. Press and hold ON/OFF button for 20 second till the LED flashes for the third time.3. Release the ON/OFF button.4. LED will start flashing rapidly. Once the LED starts blinking slowly, that indicates the device is not part of the network. |
Inclusion | 1. To include this device in a Z-Wave network, select the command on your Z Wave controller for inclusion (Install, Add Device,Add Node, Include Device, etc.). Then press the device ON/OFF button one time to include it in the network.2. Based on the controller, the controller may ask you to scan the QR code or manually enter 5 digit code under the QR codeto install the device as a secured device. You may find this QR code on the device or included in device packaging.3. After the Device is added to the network, the blue indicator LED will stop blinking. This indicates the device is installed in the Z-Wavenetwork. |
Exclusion | 1. To exclude this device from a Z-Wave network, select the setting on your Z-Wave controller for exclusion(Uninstall, Remove Device, Remove Node, Exclude Device, etc.).2. Once your controller is in exclusion mode, press the device ON/OFF button one time to exclude it from the network. The LED will startblinking. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
2 | 5 | ON/OFF |
Allows the switch to turn off after a delay. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 127 | Delayed OFF Time |
Adjusts brightness of the BLUE Indicator LED0 = OFF4 = Maximum Brightness Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
0 | Indicator stays OFF |
1 - 4 | Increase brightness of the indicator light |
Adjusts brightness of the BLUE Indicator LED0 = OFF4 = Maximum Brightness Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Indicator stays OFF |
1 - 4 | Increase brightness of the indicator light |
Sets ON time for Panic Mode Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 127 | Panic ON Time |
Sets OFF time for Panic Mode Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 127 | Panic OFF Time |
1 = OFF2 = ON3 = Last State Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | Turn OFF when power is restored |
2 | Turn ON when power is restored |
3 | Return to last state when power is restored |
0 = OFF1 = ONAs default Panic Mode is disabled Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Turn Panic Mode ON |
1 | Turn Panic Mode OFF |
Hardware Platform | ZM5101 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 0 FW: 2.00 |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-18096233 |
Z-Wave Product Id | 0x001A.0x5352.0x0504 |
Switch Type | Decorator Paddle Push with Indicator |
Firmware Updatable | Updatable by Consumer by RF |
Z-Wave Scene Type | Scene |
Neutral Wire Required | ok |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |