This is a
With your Controller in Discovery or Add Mode, tap the button on the face of the outlet. The LED will blink slowly when in ADD Mode.You should see an indication on your Controller that the device was added to the network and the LED will stop blinking.The device will appear in the list of Switches. It should display as a switch.
The PD300EMZ5-1 is a plug in the wall device designed to control dimmable lamps providing the ideal mood for every situation.Supporting Energy Monitoring the PD300EMZ5-1 will provide both a visual indication of the amount of energy the connected device is using, and also transmit this information to the Z-Wave hub for tracking purposes.Dual long life LEDs will also act as a night light when the load is off.The integrated button can be used to turn the connected device on / off, but it can also be temporarily disabled to eliminate the inadvertent operation of the device.With Over The Air upgrading supported, this device can be seamlessly updated to the most recent firmware and software features.Finally, as a Z-Wave plus product, its 30% longer range is ideal for easily creating a strong Z-Wave mesh network for an easier installation and more reliable operation.
Reset to factory default | In the event that your primary Controller is lost or otherwise inoperable, to reset the PD300EMZ5-1 and clear all network information, follow these steps:1. Tap the button on the face of the outlet five (5) times.2. Press and hold the button for 15 seconds. The LED will increasingly blink faster to indicate that a Reset is taking place. |
Inclusion | With your Controller in Discovery or Add Mode, tap the button on the face of the outlet. The LED will blink slowly when in ADD Mode.You should see an indication on your Controller that the device was added to the network and the LED will stop blinking.The device will appear in the list of Switches. It should display as a switch. |
Exclusion | Set the Controller into Removal Mode and follow its instruction to delete the PD300EMZ5-1 from the Controller.Remove the switch by tapping the button on the face of the outlet 2 times. The LED will begin blinking slowly for 10 seconds indicating that it has been removed.You should see an indication on your Controller that the device was removed from the network. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
Turns Power Monitoring ON or OFF Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | 0 - Power Monitoring OFF.1 - Power Monitoring ON |
Sets the duration the LED will change color to indicate the amount of energy being used. Size: 2 Byte, Default Value: 60
Setting | Description |
---|---|
1 - 255 | 1 - 254 - Number of seconds LED displays power level usage.255 - Power Level usage continuous ON. |
Reports the total accumulated Kilowatt Hours (kWh) and the instantaneous Wattsbeing consumed by the load. Size: 2 Byte, Default Value: 6
Setting | Description |
---|---|
0 - 255 | 0 - Automatic reporting OFF.11-255 Number of minutes between automatic reporting (Default = 6) |
Defines the timing between the steps for local attached dimmers. Size: 2 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 255 | # - Local Dim Time in mS |
Defines the number of steps switches takes from full ON to OFF or OFF to ON for all devices when an All Switch command is received. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 99 | # - Number of All switch steps |
Defines the timing between the steps for all switcheswhen an All Switch command is received. Size: 2 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 255 | # - Local Dim Time in mS |
Set the intensity of the LED. Size: 1 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 100 | 0 = OFF.1 = Very Dim.100 = Full Brightness. |
Configures the function of the integrated night light Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 3 | 0 - LED ON when the load is on and OFF when the load is off.1 - LED OFF when the load is on, and ON when the load is off.2 - LED is always on.3 - LED is always off. |
Defines the number of steps the dimmer takes from full ON to OFF or OFF to ON for Remote devices. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 99 | # - Number of remote dimmer steps |
Defines the timing between the steps for remote dimmers. Size: 2 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 255 | # - Remote Dim Time in mS |
Defines the number of steps the dimmer takes from full ON to OFF or OFF to ON for attached devices. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 99 | # - Number of attached dimmer steps |
Hardware Platform | ZM5101 |
Device Type | Light Dimmer Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 4 FW: 1.43 |
Z-Wave Version | 6.51.08 |
Certification ID | ZC10-18106267 |
Z-Wave Product Id | 0x014F.0x5044.0x3533 |
Color | White |
Supported Meter Type | Electric Energy |
Firmware Updatable | Updatable by Consumer via Internet |
Z-Wave Scene Type | Scene |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |