Quickstart

This is a secure Light Dimmer for Japan. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
SmartStart Inclusion:(Trigger:OFF-->ON)1. The LED light will flash twice (first time 6500K, second time 2700K), and send node info frame.2. Add for inclusion(SmartStart Inclusion):(If your controller does not support SmartStart inclusion, please refer to the manual for your controller for non-SmartStart inclusion.)Add the led bulb DSK into the primary controller SmartStart Provisioning List (If you dont know how to do this, refer to its manual). a)Power cycle once for led bulb.b)The led bulb will send Explorer Auto inclusion frame to start SmartStart Inclusion.c)Wait a moment, the led bulb should be added to the controller.Then the led bulb will flash once(2700K) when it has been included into the network.Note: The led bulb will start SmartStart Inclusion when it is removed from a Z-Wave network.Normal Inclusion:(Trigger:OFF-->ON-->OFF-->ON-->OFF-->ON)1. The LED light will flash twice, and send node info frame.2. Add for inclusion(Normal Inclusion):a)Set the Z-Wave network main controller into learning mode.b)Power cycle once for led bulb.c)Wait a moment, the led bulb should be added to the controller.Then the led bulb will flash once when it has been included into the network.

Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.


Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.

If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

1. Standard form factor and appearance of the light bulb with 806 lm output2. Tunable white: dimmable from 5% to 100%, tunable from 2700K to 6500K.3.Possible to be included in groups, scenes, or schedules 4Suitable for indoor lighting: Corridors, Bedroom, Living Room, etc.5.Voltage: 100V

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.

Reset the device :Trigger:OFF-->ON-->OFF-->ON-->OFF-->ON-->OFF-->ON-->OFF-->ON-->OFF-->ONLed bulb re-power 6 times (between 0.5-2 seconds each time); If the 6th power on, the led bulb flashes twice (first time 6500K, second time 2700K), which means that the resetting is successful. it will send Device Reset Locally Command.Please use this procedure only when the network primary controller is missing or otherwise inoperable.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion

SmartStart Inclusion:(Trigger:OFF-->ON)1. The LED light will flash twice (first time 6500K, second time 2700K), and send node info frame.2. Add for inclusion(SmartStart Inclusion):(If your controller does not support SmartStart inclusion, please refer to the manual for your controller for non-SmartStart inclusion.)Add the led bulb DSK into the primary controller SmartStart Provisioning List (If you dont know how to do this, refer to its manual). a)Power cycle once for led bulb.b)The led bulb will send Explorer Auto inclusion frame to start SmartStart Inclusion.c)Wait a moment, the led bulb should be added to the controller.Then the led bulb will flash once(2700K) when it has been included into the network.Note: The led bulb will start SmartStart Inclusion when it is removed from a Z-Wave network.Normal Inclusion:(Trigger:OFF-->ON-->OFF-->ON-->OFF-->ON)1. The LED light will flash twice, and send node info frame.2. Add for inclusion(Normal Inclusion):a)Set the Z-Wave network main controller into learning mode.b)Power cycle once for led bulb.c)Wait a moment, the led bulb should be added to the controller.Then the led bulb will flash once when it has been included into the network.

Exclusion

Trigger:OFF-->ON-->OFF-->ON-->OFF-->ON1. LED Bulb will light up with previously saved state and send node info frame.2. Remove for exclusion:a)Assuming led bulb was added to controller and was power on.b)Set the Z-Wave network main controller into removing mode.c)Power cycle triple for led bulb (OFF->ON->OFF->ON->OFF->ON).d)Wait a moment, the led bulb should be removed from the controller.Then the led bulb will flash once and dim to 5%.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline:1. When the state of the LED Bulb is changed:The Bulb will Send Switch Multilevel Report2. Device Reset Locally.3. Switch Color Command.

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.

IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.

Parameter 2: Enable/Disable save the lamp state.

Enable/Disable save the lamp state.0x00 = Enable save the lamp status0x01 =The lamps status is forced to open 0x02 = The lamps status is forced to close
Size: 1 Byte, Default Value: 0

Setting Description
0 - 2 Enable/Disable save the lamp state.

Parameter 80: Enable/Disable send notifications to associated devices

Enable to send notifications to associated devices(Group 1) when the state of LED Bulb is changed.0 = Nothing.1= Switch Multilevel Report.
Size: 1 Byte, Default Value: 1

Setting Description
0 - 1 Enable/Disable send notifications to associated devices

Parameter 81: Adjusting the color temperature in warm white color component

Adjusting the color temperature in warm white color component. available value: 0x0A8C-0x1387Warm White(0x0A8C(2700k) ~ 0x1387 (4999k))
Size: 2 Byte, Default Value: 2700

Setting Description
2700 - 4999 Adjusting the color temperature in warm white color component

Parameter 82: Adjusting the color temperature in cold white color component.available value:0x1388-0x1964 Cold White (0x1388 (5000k) ~ 0x1964 (6500k))

Adjusting the color temperature in cold white color component. available value:0x1388-0x1964Cold White (0x1388 (5000k) ~ 0x1964 (6500k))
Size: 2 Byte, Default Value: 6500

Setting Description
5000 - 6500 Adjusting the color temperature in cold white color component.available value:0x1388-0x1964 Cold White (0x1388 (5000k) ~ 0x1964 (6500k))

Technical Data

Hardware Platform ZM5101
Device Type Light Dimmer Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 2.07
Z-Wave Version 6.81.03
Certification ID ZC10-19016346
Z-Wave Product Id 0x039F.0x060A.0x0021
Firmware Updatable Updatable by Manufacturer
Communications Protocol Manufacturer Proprietary Protocol
Security V2 S2_UNAUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info
  • Association V2
  • Basic
  • Configuration
  • Device Reset Locally
  • Manufacturer Specific V2
  • Powerlevel
  • Scene Activation
  • Scene Actuator Conf
  • Security
  • Security 2
  • Supervision
  • Switch Color V2
  • Switch Multilevel V2
  • Transport Service V2
  • Version V2
  • Zwaveplus Info V2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall controllers.
  • Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.
  • Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.
  • Inclusion — is the process of adding new Z-Wave devices into a network.
  • Exclusion — is the process of removing Z-Wave devices from the network.
  • Association — is a control relationship between a controlling device and a controlled device.
  • Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.
  • Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.