Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
-Click [Add] icon in Z-Wave Controller.-Press the Net_Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second.-If Inclusion Process is successful, Green LED will turn off.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Carbon monoxide(CO) is a dangerous poison.It isa colorless, odorless and tasteless gas. CO gasis generated by combustion of carbonaceousmaterials,namely,when not enough oxygen isavailable.This device is intended for use within privatehousing.It is suitable neither for commercial orindustrial applications nor for use on recreationalcraft or commercial vessels.

Reset to factory default Long press Net_Button at least 10 seconds in the product. -Device Reset Locally notification is Transmitted-The green LED stays on for 2 seconds and then goes off.Please use this procedure only when the network primary controller is missing or otherwiseinoperable.
Inclusion -Click [Add] icon in Z-Wave Controller.-Press the Net_Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second.-If Inclusion Process is successful, Green LED will turn off.
Exclusion -Click [Remove] icon in Z-Wave Controller.-Press the Net_Button 3 times within 1.5s -If Exclusion Process is successful, Green LED is Blinking 6 times, then turn off.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Association group 1: Lifeline association group- Maximum supported node is 5.Include command classes: Battery report, Notification report, and Device Reset Locally notification.
2 5 Association group 2: Root Device group(Basic set)- Maximum supported node is 5.TheSensorsendsaBasicSetcommandtodirectlytriggerdevices(likealight,switch,etc.)inresponsetoevents.ThevalueoftheBasicSetcommand(e.g.Sirentrigger)isconfiguredusingCOornoCO

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 255 FW: 2.00
Z-Wave Version 6.71.03
Certification ID ZC10-19016358
Z-Wave Product Id 0x0260.0x8012.0x1000
Communications Protocol Z-Wave Serial API
Supported Notification Types CO Alarm
Color White
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Notification Sensor