Quickstart

This is a secure Window Covering - Pos/End Aware for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.1. Connect the power to Shutter Control (see manuals Installation).2. Put the Z-Wave gateway or control panel into Inclusion mode (please refer to the Z-Wave gateway or control panel manual).3. Within 1.5 seconds, press the Function Button 3 times.4. Refer to the operation manual of the Z-Wave gateway or control panel to complete the adding process.5. If the device has already been added (included) into another Z-Wave Gateway/Control Panel, or if the device is unable to be added into the current Z-Wave Gateway/Control Panel, try removing it first (see Removing Device).



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The SCM-2ZW is a Z-Wave roller shutter control that provides remote operation of roller shutters for home automation and security purposes. Automatically or remotely roll up, down or stop mid-way, the SCM-2ZW is directly connected to and controls motorized window treatments, interior and exterior shades and blinds, projection screen, and garage door or driveway gate of your home.With SCM-2ZW, all roller shutters in the house can be configured to automatically open or close according to preset schedules and scenarios.

Reset to factory default (Only use factory reset when network Control Panel/Gateway is missing or inoperable).Factory resetting the device will restore it to factory default settings (i.e. excluded from Z-Wave network).Please use the reset procedure only when the primary controller is missing or inoperable.Press and hold the Function Button of the device for 10 seconds to factory reset.
Inclusion This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.1. Connect the power to Shutter Control (see manuals Installation).2. Put the Z-Wave gateway or control panel into Inclusion mode (please refer to the Z-Wave gateway or control panel manual).3. Within 1.5 seconds, press the Function Button 3 times.4. Refer to the operation manual of the Z-Wave gateway or control panel to complete the adding process.5. If the device has already been added (included) into another Z-Wave Gateway/Control Panel, or if the device is unable to be added into the current Z-Wave Gateway/Control Panel, try removing it first (see Removing Device).
Exclusion The device must be removed from existing Z-Wave network before being added into another.1. Put the Z-Wave gateway or control panel into Exclusion mode (please refer to the Z-Wave gateway or control panel manual).2. Within 1.5 seconds, press the Function Button 3 times and the device will be removed from the Z-Wave network.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus LifelineSwitch MultilevelCC,V4(COMMAND_CLASS_SWITCH_MULTILEVEL)Device Reset Locally CC, V4 (COMMAND_CLASS_DEVICE_RESET_LOCALLY)When SCM changes its position: [SWITCH_MULTILEVEL_REPORT]

Configuration Parameters

Parameter 1: Up Time Setting

For parameter 1, users can set the open time (from down to up) to a value that ranges from 0 to 255 seconds.
Size: 2 Byte, Default Value: 240

Setting Description
0 - 255 The ranges from 0 to 255 seconds.

Parameter 2: Close Time Setting

For parameter 2, users can set the close time (from up to down) time to a value that ranges from 0 to 255 seconds.
Size: 2 Byte, Default Value: 240

Setting Description
0 - 255 The ranges from 0 to 255 seconds.

Parameter 3: Current Position

For parameter 3, users can set the current position to a value that ranges from 0% to 99%.
Size: 2 Byte, Default Value: 99

Setting Description
0 - 99 The ranges from 0% to 99%.

Technical Data

Hardware Platform ZM5202
Device Type Window Covering - Pos/End Aware
Network Operation Always On Slave
Firmware Version HW: 255 FW: 4.01
Z-Wave Version 6.81.01
Certification ID ZC10-19036397
Z-Wave Product Id 0x018E.0x0004.0x0005
Window Covering Control Features Supports Up/Down Motion
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Window Covering - Pos/End Aware