Quickstart

This is a secure Sound Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
This product supports Security 2 Command Class. While a Security S2 enabled Controller is needed in order to fully use the security feature. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network willact as repeaters regardless of vendor to increase reliability of the network.1. Set your Z-Wave Controller into its 'Add Device' mode in order to add Chime into your Z-Wave system. Refer to the Controller's manual if you are unsure of how to perform this step.2. Power on Chime via the provided power adapter; its LED will be breathing white light all the time.3. Click Chime Action Button once, it will quickly flash white light for 30 seconds until Chime is added into the network. It will become constantly bright white light after being assigned a NodeID.4. If your Z-Wave Controller supports S2 encryption, enter the first 5 digits of DSK into your Controller's interface if/when requested. The DSK is printed on Chime's housing.5. If Adding fails, it will slowly flash white light 3 times and then become breathing white light; repeat steps 1 to 4. Contact us for further support if needed.6. If Adding succeeds, it will quickly flash white light 3 times and then become off. Now, Chime is a part of your Z-Wave home control system. You can configure it and its automations via your Z-Wave system; please refer to your software's user guide for precise instructions.Note:If Action Button is clicked again during the Learn Mode, the Learn Mode will exit. At the same time, Indicator Light will extinguish immediately, and then become breathing white light.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

- S2 Security.- Not only a doorbell, but also can be used as a siren via setting.- Can be wireless controlled by more Button, up to 3.- Longer Button control distance, up to 120m.- Built-in multiple tones, up to 30.- Built-in multiple adjustable Light Effect.

Reset to factory default If the primary controller is missing or inoperable, you may need to reset the device to factory settings.Make sure the Chime is powered. To complete the reset process manually, press and hold the Action Button for at least 20s. The LED indicator will quickly flash white light 3 times and then become breathing white light, which indicates the reset operation is successful. Otherwise, please try again. Contact us for further support if needed.Note:1. This procedure should only be used when the primary controller is missing or inoperable.2. Factory Reset Chime will:(a) Remove Chime from Z-Wave network;(b) Delete the Association setting;(c) Restore the configuration settings to the default.(Except configuration parameter 51/52/53/54)
Inclusion This product supports Security 2 Command Class. While a Security S2 enabled Controller is needed in order to fully use the security feature. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network willact as repeaters regardless of vendor to increase reliability of the network.1. Set your Z-Wave Controller into its 'Add Device' mode in order to add Chime into your Z-Wave system. Refer to the Controller's manual if you are unsure of how to perform this step.2. Power on Chime via the provided power adapter; its LED will be breathing white light all the time.3. Click Chime Action Button once, it will quickly flash white light for 30 seconds until Chime is added into the network. It will become constantly bright white light after being assigned a NodeID.4. If your Z-Wave Controller supports S2 encryption, enter the first 5 digits of DSK into your Controller's interface if/when requested. The DSK is printed on Chime's housing.5. If Adding fails, it will slowly flash white light 3 times and then become breathing white light; repeat steps 1 to 4. Contact us for further support if needed.6. If Adding succeeds, it will quickly flash white light 3 times and then become off. Now, Chime is a part of your Z-Wave home control system. You can configure it and its automations via your Z-Wave system; please refer to your software's user guide for precise instructions.Note:If Action Button is clicked again during the Learn Mode, the Learn Mode will exit. At the same time, Indicator Light will extinguish immediately, and then become breathing white light.
Exclusion 1. Set your Z-Wave Controller into its ' Remove Device' mode in order to remove Chime from your Z-Wave system. Refer to the Controller's manual if you are unsure of how to perform this step.2. Power on Chime via the provided power adapter; its LED will be off.3. Click Chime Action Button 6 times quickly; it will bright white light, up to 2s.4. If Removing fails, it will keep off; repeat steps 1 to 3. Contact us for further support if needed.5. If Removing succeeds, it will quickly flash white light 3 times and then become breathing white light. Now, Chime is removed from Z-Wave network successfully.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Lifeline group.(1) Device Reset Locally Notification, issued when Factory Reset is performed.(2) Sound Switch Tone Play Report, issued when a tone has started playing.(3) Sound Switch Configuration Report, issued when volume or default tone has changed.(4) Notification Report (Type=0x0E; Event=0x01), issued when Chime starts playing tone. (5) Notification Report (Type=0x0E; Event=0x00), issued when Chime stops playing tone.(6) Notification Report (Type=0x07; Event=0x09), issued when Chime is tampered and moved.(7) Notification Report (Type=0x08; Event=0x0A), issued when Button is low battery.(8) Notification Report (Type=0x08; Event=0x00), issued when Button comes back to normal battery.(9) Configuration Report (Parameter=0x32), issued when Pairing Button Mode is triggered.(10) Configuration Report (Parameter=0x33), issued when Unpairing or Pairing Button Mode finishes.
2 5 Mirror of Endpoint 1, group 2. When Endpoint 1 starts playing tone or stops playing tone, Nodes associated are controlled and will receive aBasic Set CC.
3 5 Mirror of Endpoint 2, group 2. When Endpoint 2 starts playing tone or stops playing tone, Nodes associated are controlled and will receive aBasic Set CC.
4 5 Mirror of Endpoint 3, group 2. When Endpoint 3 starts playing tone or stops playing tone, Nodes associated are controlled and will receive aBasic Set CC.
5 5 Mirror of Endpoint 4, group 2. When Endpoint 4 starts playing tone or stops playing tone, Nodes associated are controlled and will receive aBasic Set CC.
6 5 Mirror of Endpoint 5, group 2. When Endpoint 5 starts playing tone or stops playing tone, Nodes associated are controlled and will receive aBasic Set CC.
7 5 Mirror of Endpoint 6, group 2. When Endpoint 6 starts playing tone or stops playing tone, Nodes associated are controlled and will receive aBasic Set CC.
8 5 Mirror of Endpoint 7, group 2. When Endpoint 7 starts playing tone or stops playing tone, Nodes associated are controlled and will receive aBasic Set CC.
9 5 Mirror of Endpoint 8, group 2. When Endpoint 8 starts playing tone or stops playing tone, Nodes associated are controlled and will receive aBasic Set CC.

Configuration Parameters

Parameter 1: Configure the Light Effect and Tone Play Mode for Endpoint 1(Browse).

Please refer to the Product Manual for more details.
Size: 4 Byte, Default Value: 16777216

Setting Description
16777216 - 2147418112 Configure the Light Effect and Tone Play Mode for Endpoint 1(Browse).

Parameter 16: Configure #1 Light Effect.

Please refer to the Product Manual for more details.
Size: 4 Byte, Default Value: 1259934723

Setting Description
0 - 2147483647 The Light Effect is displayed cyclically, and the maximum display duration is equal to the total duration of the tone playback. In other words, the Light Effect will be displayed in a loop until stop playing tone.

Parameter 17: Configure #2 Light Effect.

Please refer to the Product Manual for more details.
Size: 4 Byte, Default Value: 842137603

Setting Description
0 - 2147483647 The Light Effect is displayed cyclically, and the maximum display duration is equal to the total duration of the tone playback. In other words, the Light Effect will be displayed in a loop until stop playing tone.

Parameter 18: Configure #3 Light Effect.

Please refer to the Product Manual for more details.
Size: 4 Byte, Default Value: 2162947

Setting Description
0 - 2147483647 The Light Effect is displayed cyclically, and the maximum display duration is equal to the total duration of the tone playback. In other words, the Light Effect will be displayed in a loop until stop playing tone.

Parameter 19: Configure #4 Light Effect.

Please refer to the Product Manual for more details.
Size: 4 Byte, Default Value: 553648131

Setting Description
0 - 2147483647 The Light Effect is displayed cyclically, and the maximum display duration is equal to the total duration of the tone playback. In other words, the Light Effect will be displayed in a loop until stop playing tone.

Parameter 2: Configure the Light Effect and Tone Effect for Endpoint 2(Tampering).

Please refer to the Product Manual for more details.
Size: 4 Byte, Default Value: 16777217

Setting Description
16777216 - 2147483647 Configure the Light Effect and Tone Effect for Endpoint 2(Tampering).

Parameter 20: Configure #5 Light Effect.

Please refer to the Product Manual for more details.
Size: 1 Byte, Default Value: 10

Setting Description
0 - 2147483647 The Light Effect is displayed cyclically, and the maximum display duration is equal to the total duration of the tone playback. In other words, the Light Effect will be displayed in a loop until stop playing tone.

Parameter 21: Configure #6 Light Effect.

Please refer to the Product Manual for more details.
Size: 4 Byte, Default Value: 2560

Setting Description
0 - 2147483647 The Light Effect is displayed cyclically, and the maximum display duration is equal to the total duration of the tone playback. In other words, the Light Effect will be displayed in a loop until stop playing tone.

Parameter 22: Configure #7 Light Effect.

Please refer to the Product Manual for more details.
Size: 4 Byte, Default Value: 553648129

Setting Description
0 - 2147483647 The Light Effect is displayed cyclically, and the maximum display duration is equal to the total duration of the tone playback. In other words, the Light Effect will be displayed in a loop until stop playing tone.

Parameter 255: Factory Reset or Initialization (Write Only)

Parameter 51/52/53/54 will not restore the configuration settings to the default when Factory Reset or Initialization is performed.
Size: 4 Byte, Default Value: 0

Setting Description
0 Initialization: Initialize all configuration parameters to default values.
1431655765 Factory Reset: Restore the product to factory settings and remove from the network.

Parameter 3: Configure the Light Effect and Tone Effect for Endpoint 3(Doorbell 1).

Please refer to the Product Manual for more details.
Size: 4 Byte, Default Value: 33554433

Setting Description
16777216 - 2147483647 Configure the Light Effect and Tone Effect for Endpoint 3(Doorbell 1).

Parameter 32: Configure how to send Basic Set to nodes in Group 2.


Size: 1 Byte, Default Value: 3

Setting Description
0 Dont send Basic Set.
1 When Endpoint 1 starts playing tone, send Basic Set 0xFF. When Endpoint 1 stops playing tone, dont send Basic Set.
2 When Endpoint 1 starts playing tone, send Basic Set 0x00. When Endpoint 1 stops playing tone, dont send Basic Set.
3 When Endpoint 1 starts playing tone, send Basic Set 0xFF. When Endpoint 1 stops playing tone, send Basic Set 0x00.
4 When Endpoint 1 starts playing tone, send Basic Set 0x00. When Endpoint 1 stops playing tone, send Basic Set 0xFF.

Parameter 33: Configure how to send Basic Set to nodes in Group 3.


Size: 1 Byte, Default Value: 3

Setting Description
0 Dont send Basic Set.
1 When Endpoint 2 starts playing tone, send Basic Set 0xFF. When Endpoint 2 stops playing tone, dont send Basic Set.
2 When Endpoint 2 starts playing tone, send Basic Set 0x00. When Endpoint 2 stops playing tone, dont send Basic Set.
3 When Endpoint 2 starts playing tone, send Basic Set 0xFF. When Endpoint 2 stops playing tone, send Basic Set 0x00.
4 When Endpoint 2 starts playing tone, send Basic Set 0x00. When Endpoint 2 stops playing tone, send Basic Set 0xFF.

Parameter 34: Configure how to send Basic Set to nodes in Group 4.


Size: 1 Byte, Default Value: 3

Setting Description
0 Dont send Basic Set.
1 When Endpoint 3 starts playing tone, send Basic Set 0xFF. When Endpoint 3 stops playing tone, dont send Basic Set.
2 When Endpoint 3 starts playing tone, send Basic Set 0x00. When Endpoint 3 stops playing tone, dont send Basic Set.
3 When Endpoint 3 starts playing tone, send Basic Set 0xFF. When Endpoint 3 stops playing tone, send Basic Set 0x00.
4 When Endpoint 3 starts playing tone, send Basic Set 0x00. When Endpoint 3 stops playing tone, send Basic Set 0xFF.

Parameter 35: Configure how to send Basic Set to nodes in Group 5.


Size: 1 Byte, Default Value: 3

Setting Description
0 Dont send Basic Set.
1 When Endpoint 4 starts playing tone, send Basic Set 0xFF. When Endpoint 4 stops playing tone, dont send Basic Set.
2 When Endpoint 4 starts playing tone, send Basic Set 0x00. When Endpoint 4 stops playing tone, dont send Basic Set.
3 When Endpoint 4 starts playing tone, send Basic Set 0xFF. When Endpoint 4 stops playing tone, send Basic Set 0x00.
4 When Endpoint 4 starts playing tone, send Basic Set 0x00. When Endpoint 4 stops playing tone, send Basic Set 0xFF.

Parameter 36: Configure how to send Basic Set to nodes in Group 6.


Size: 1 Byte, Default Value: 3

Setting Description
0 Dont send Basic Set.
1 When Endpoint 5 starts playing tone, send Basic Set 0xFF. When Endpoint 5 stops playing tone, dont send Basic Set.
2 When Endpoint 5 starts playing tone, send Basic Set 0x00. When Endpoint 5 stops playing tone, dont send Basic Set.
3 When Endpoint 5 starts playing tone, send Basic Set 0xFF. When Endpoint 5 stops playing tone, send Basic Set 0x00.
4 When Endpoint 5 starts playing tone, send Basic Set 0x00. When Endpoint 5 stops playing tone, send Basic Set 0xFF.

Parameter 37: Configure how to send Basic Set to nodes in Group 7.


Size: 1 Byte, Default Value: 3

Setting Description
0 Dont send Basic Set.
1 When Endpoint 6 starts playing tone, send Basic Set 0xFF. When Endpoint 6 stops playing tone, dont send Basic Set.
2 When Endpoint 6 starts playing tone, send Basic Set 0x00. When Endpoint 6 stops playing tone, dont send Basic Set.
3 When Endpoint 6 starts playing tone, send Basic Set 0xFF. When Endpoint 6 stops playing tone, send Basic Set 0x00.
4 When Endpoint 6 starts playing tone, send Basic Set 0x00. When Endpoint 6 stops playing tone, send Basic Set 0xFF.

Parameter 38: Configure how to send Basic Set to nodes in Group 8.


Size: 1 Byte, Default Value: 3

Setting Description
0 Dont send Basic Set.
1 When Endpoint 7 starts playing tone, send Basic Set 0xFF. When Endpoint 7 stops playing tone, dont send Basic Set.
2 When Endpoint 7 starts playing tone, send Basic Set 0x00. When Endpoint 7 stops playing tone, dont send Basic Set.
3 When Endpoint 7 starts playing tone, send Basic Set 0xFF. When Endpoint 7 stops playing tone, send Basic Set 0x00.
4 When Endpoint 7 starts playing tone, send Basic Set 0x00. When Endpoint 7 stops playing tone, send Basic Set 0xFF.

Parameter 39: Configure how to send Basic Set to nodes in Group 9.


Size: 1 Byte, Default Value: 3

Setting Description
0 Dont send Basic Set.
1 When Endpoint 8 starts playing tone, send Basic Set 0xFF. When Endpoint 8 stops playing tone, dont send Basic Set.
2 When Endpoint 8 starts playing tone, send Basic Set 0x00. When Endpoint 8 stops playing tone, dont send Basic Set.
3 When Endpoint 8 starts playing tone, send Basic Set 0xFF. When Endpoint 8 stops playing tone, send Basic Set 0x00.
4 When Endpoint 8 starts playing tone, send Basic Set 0x00. When Endpoint 8 stops playing tone, send Basic Set 0xFF.

Parameter 4: Configure the Light Effect and Tone Effect for Endpoint 4(Doorbell 2).

Please refer to the Product Manual for more details.
Size: 4 Byte, Default Value: 33554433

Setting Description
16777216 - 2147483647 Configure the Light Effect and Tone Effect for Endpoint 4(Doorbell 2).

Parameter 48: Tigger Unpairing Button Mode (Write Only)

(1) Can trigger unpairing multiple Buttons at one time.(2) User does not need to do anything to Button.(3) Indicator Light will quickly flash white light 3 times when Unpairing Button Mode finishes.
Size: 1 Byte, Default Value: 0

Setting Description
1 Tigger Unpairing #1 Button Mode.
2 Tigger Unpairing #2 Button Mode.
3 Tigger Unpairing #2 and #1 Button Mode.
4 Tigger Unpairing #3 Button Mode.
5 Tigger Unpairing #3 and #1 Button Mode.
6 Tigger Unpairing #3 and #2 Button Mode.
7 Tigger Unpairing #3, #2 and #1 Button Mode.

Parameter 49: Tigger Pairing Button Mode (Write Only)

(1) Can NOT trigger pairing multiple Buttons at one time.(2) Pairing time is up to 10 seconds. In this time period, user MUST manually click Ring Button 3 times quickly. Otherwise it cannot be paired successfully.(3) Each successful pairing will overwrite the previous paired Button which has the same Button Number.
Size: 1 Byte, Default Value: 0

Setting Description
0 Exit Pairing Button Mode.
1 Tigger Pairing #1 Button Mode.
2 Tigger Pairing #2 Button Mode.
4 Tigger Pairing #3 Button Mode.

Parameter 5: Configure the Light Effect and Tone Effect for Endpoint 5(Doorbell 3).

Please refer to the Product Manual for more details.
Size: 4 Byte, Default Value: 33554433

Setting Description
16777216 - 2147483647 Configure the Light Effect and Tone Effect for Endpoint 5(Doorbell 3).

Parameter 50: Report which Pairing Button Mode is triggered (Read Only)

Once Pairing Button Mode is triggered, node will automatically send this configuration report via Lifeline to inform which Button is waiting for being paired.
Size: 1 Byte, Default Value: 0

Setting Description
0 There is no Pairing Button Mode being triggered.
1 Pairing #1 Button Mode is triggered.
2 Pairing #2 Button Mode is triggered.
4 Pairing #3 Button Mode is triggered.

Parameter 51: Report which Buttons had been paired (Read Only)

Once Unpairing or Pairing Button Mode finishes, node will automatically send this configuration report via Lifeline to inform which Buttons had been paired. This parameter does not restore to the default value when Chime is removed from the network or reset the factory settings.
Size: 1 Byte, Default Value: 0

Setting Description
0 There is no paired Button.
1 #1 Button had been paired.
2 #2 Button had been paired.
3 #2 and #1 Button had been paired.
4 #3 Button had been paired.
5 #3 and #1 Button had been paired.
6 #3 and #2 Button had been paired.
7 #3, #2 and #1 Button had been paired.

Parameter 52: Get the information of #1 Button (Read Only)

This parameter does not restore to the default value when Chime is removed from the network or reset the factory settings.
Size: 4 Byte, Default Value: 0

Setting Description
0 #1 Button is unpaired.
1 - 2147483647 Information about #1 Button, including battery voltage (unit is mV) and software version.

Parameter 53: Get the information of #2 Button (Read Only)

This parameter does not restore to the default value when Chime is removed from the network or reset the factory settings.
Size: 4 Byte, Default Value: 0

Setting Description
0 #2 Button is unpaired.
1 - 134217727 Information about #2 Button, including battery voltage (unit is mV) and software version.

Parameter 54: Get the information of #3 Button (Read Only)

This parameter does not restore to the default value when Chime is removed from the network or reset the factory settings.
Size: 4 Byte, Default Value: 0

Setting Description
0 #3 Button is unpaired.
1 - 2147483647 Information about #3 Button, including battery voltage (unit is mV) and software version.

Parameter 6: Configure the Light Effect and Tone Effect for Endpoint 6(Environment).

Please refer to the Product Manual for more details.
Size: 4 Byte, Default Value: 67108864

Setting Description
16777216 - 2147483647 Configure the Light Effect and Tone Effect for Endpoint 6(Environment).

Parameter 7: Configure the Light Effect and Tone Effect for Endpoint 7(Security).

Please refer to the Product Manual for more details.
Size: 4 Byte, Default Value: 67108864

Setting Description
16777216 - 2147483647 Configure the Light Effect and Tone Effect for Endpoint 7(Security).

Parameter 8: Configure the Light Effect and Tone Effect for Endpoint 8(Emergency).

Please refer to the Product Manual for more details.
Size: 4 Byte, Default Value: 67108864

Setting Description
16777216 - 2147483647 Configure the Light Effect and Tone Effect for Endpoint 8(Emergency).

Parameter 96: Enable or Disable the ability that click the Action Button to stop a playing tone.


Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable

Technical Data

Hardware Platform ZM5101
Device Type Sound Switch
Network Operation Always On Slave
Firmware Version HW: 162 FW: 1.04
Z-Wave Version 6.71.03
Certification ID ZC10-19046415
Z-Wave Product Id 0x0371.0x0203.0x00A2
Color White
Supported Notification Types Home SecurityPower ManagementSiren
Sensors Vibration/Shock (Binary)
Outdoor Use ok
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
Australia / New ZealandSound Switch