This is a
After mounting the UZB controller to your PC and running the PC Controller program, click the Add button in the PC Controller program. Press the button on the Smart Power Strip for more than five seconds after you plug the Smart Power Strip into a power outlet and it will include to the network controller, while flashing the red button on the LED Smart Power Strip.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
This device is a smart light switch using 1 wire AC line.You can control the light from the remote.Input AC power : 220V
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
With the device powered, press and hold the third button for 10 seconds.he LED of the button will flash red after 5 seconds, it will turn green, then it will flash red again. Then release the button.After a few moments, the entire LED is blinking and the green LED stops flashing.Please use the procedure only in the event thant the network primary controller is missing or otherwise inoperable.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device. To wakeup the device please perform the following action: To wake up this device, either press the switch button or try remote control.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus LifelineProfile General = 0x00 Profile General Lifeline = 0x01 Command Class - Device Reset Locally Notification - Notification Report - Multilevel Sensor Report- Version Report- Configuration Report - Battery Report |
2 | 5 | OnOff Noti EP 1 rfile Notification = 0x71 Command Class - Notification Report |
3 | 5 | OnOff Noti EP 2rfile Notification = 0x71 Command Class - Notification Report |
4 | 5 | OnOff Noti EP 3 rfile Notification = 0x71 Command Class - Notification Report |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
This parameter determines the period in which the temperature and humidity values are transmitted.default Value : 0x258 (integer 600 --> 10 minutes) Size: 2 Byte, Default Value: 600
Setting | Description |
---|---|
60 - 3600 | If value is 0x258, The device reports temperature and humidity every 10 minutes. |
This parameter determines the amount of temperature change that must be reported.(Temperature Variation /0x14 (integer 20 -> 2.0C)In the receiving part, divide this value by 10 and treat it as one decimal place.)Default Value : 0x14Possible value : 0x0a ~ 0x1E Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
10 - 30 | the value is set to 20 and If there is a change in temperature above 2 degrees, the temperature is reported regardless of the reporting period. |
This parameter determines the amount of humidity change that must be reported(Humidity Variation /0x0A (integer 10 -> 10%))Default Value : 0x0APossible values : 0x05~0x14 Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
5 - 20 | he value is set to 10 and If there is a change in humidity above 10 %, the humidity is reported regardless of the reporting period. |
Hardware Platform | ZM5101 |
Device Type | On/Off Power Switch |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 3 FW: 39.34 |
Z-Wave Version | 6.81.04 |
Certification ID | ZC10-19046430 |
Z-Wave Product Id | 0x018C.0x0059.0x0001 |
Supported Notification Types | Heat Alarm |
Color | White |
Sensors | Humidity |
Switch Type | Push Button with Indicator |
Electric Load Type | FluorescentIncandescentLED |
Outdoor Use | ok |
Firmware Updatable | Updatable by Manufacturer Representative |
Security V2 | S2_UNAUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |