Quickstart
This is a
secure
On/Off Power Switch for XXXQFrequencyName.
To run this device please connect it to your mains power supply.
To add this device to your network execute the following action:
1. Put the controller into INCLUSION mode. Follow the instructions provided by the controller manufacturer.2. Touch and hold any key on the panel for more than 5 seconds. All indication lights will blink in blue. At this point release the key, the touch panel will start the inclusion process.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from
Z-Wave Alliance Product
data and may be incomplete. Please refer to the
Manufacturers Manual for more information.
Product Description
With a stunning glass face and an advanced capacitive touch sensor, all you need to do is just use a finger for turning your lights on and off. Tap once on the backlit touch button to switch the device on and tap it again to turn it off, its that simple. This 3 Touch Switch ensures an accurate response to every command that is sent through it. The Hogar 3 Touch Switch can operate either independently or as a part of the Hogar smart home automation system, and even with any other certified Z-Wave home automation system. It is an extremely easy-to-use panel that can be installed in a standard BS 2 gang box. Its operating capabilities include a bi-stable mode, a relay mode or a touch pulse mode for scene control with a maximum load current of 3 amp. It communicates with the Hogar smart home automation system using the Z-Wave wireless communication protocol.
Reset to factory default |
1. Press the config button 5 times, Indication LED lights will blink red in color, touch panel will start local reset. Touch panel switch will erase network inclusion state after local reset. Please use this procedure only when the network primary controller is missing or otherwise inoperable |
Inclusion |
1. Put the controller into INCLUSION mode. Follow the instructions provided by the controller manufacturer.2. Touch and hold any key on the panel for more than 5 seconds. All indication lights will blink in blue. At this point release the key, the touch panel will start the inclusion process. |
Exclusion |
1. Put the controller into EXCLUSION mode. Follow the instructions provided by the controller manufacturer.2. Touch and hold any key on the panel for more than 5 seconds. All indication lights will blink blue in color. At this point release the key, the touch panel will start the exclusion process. |
NIF |
XXXNIF |
Wakeup |
XXXWakeupDescription |
Protection |
XXXProtection |
FirmwareUpdate |
XXXFirmwareUpdate |
SetAssociation |
XXXSetAssociation |
Association Groups:
Group Number |
Maximum Nodes |
Description |
1 |
1 |
Name: Lifeline Command: Device Reset Locally Notification Switch Binary Report |
2 |
5 |
Name: HGT-01 Command: Basic Set Send Basic Set command to the other node in this association group when active endpoint 1. |
3 |
5 |
Name: HGT-01 Command: Switch Binary Set Send Switch Binary Set command to the other node in this association group when active endpoint 1. |
4 |
5 |
Name: HGT-02 Command: Basic Set Send Basic Set command to the other node in this association group when active endpoint 2. |
5 |
5 |
Name: HGT-02 Command: Switch Binary Set Send Switch Binary Set command to the other node in this association group when active endpoint 2. |
6 |
5 |
Name: HGT-03 Command: Basic Set Send Basic Set command to the other node in this association group when active endpoint 3. |
7 |
5 |
Name: HGT-03 Command: Switch Binary Set Send Switch Binary Set command to the other node in this association group when active endpoint 3. |
Technical Data
Hardware Platform |
ZM5202 |
Device Type |
On/Off Power Switch |
Network Operation |
Always On Slave |
Firmware Version |
HW: 10 FW: 2.05 |
Z-Wave Version |
6.81.01 |
Certification ID |
ZC10-19046448 |
Z-Wave Product Id |
0x0293.0x0003.0x4413 |
Firmware Updatable |
Updatable by Professional/Technician |
Electric Load Type |
Dimmable ELV (Magnetic)Dimmable FluorescentDimmable LEDDimmable MLV (Magnetic)ELV (Electronic)FluorescentIncandescentInductive (e.g. Motor)LEDMLV (Magnetic) |
Neutral Wire Required |
ok |
Frequency |
XXfrequency |
Maximum transmission power |
XXantenna |