This is a
1. Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual on how to turn your controller into inclusion).2. Power on the in-wall dimmer and set it into inclusion mode. There are two methods to set the in-wall dimmer into inclusion mode:1)Repower on the dimmer, it will be set into inclusion mode automatically, and waiting to be included.2)Triple press the action button on the dimmer, it will set the dimmer into inclusion mode.The connected light will stay solid on for 3 seconds to indicate successful inclusion.
The micro smart dimmer is a Z-Wave device designed to work with various types of light sources. It may beconnected to two-wire or three-wire configuration so it can operate with or without neutral lead. Thedimmer can switch or dim connected light source either through Z-Wave devices or through the wallswitch connected directly to it. The smart dimmer is equipped with an algorithm of smart light sourcedetection which makes configuration easier and ensures high compatibility of the device. It may be usedas a switch with non-dimmable light sources (in 3-wire connection).
Reset to factory default | Press and hold down the action button for over 10 seconds, the dimmer will be reset to factory defaults.Note: Factory reset is not recommended for exclusion, please use this procedure only if the primary controller/gateway is missing or otherwise inoperable. |
Inclusion | 1. Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual on how to turn your controller into inclusion).2. Power on the in-wall dimmer and set it into inclusion mode. There are two methods to set the in-wall dimmer into inclusion mode:1)Repower on the dimmer, it will be set into inclusion mode automatically, and waiting to be included.2)Triple press the action button on the dimmer, it will set the dimmer into inclusion mode.The connected light will stay solid on for 3 seconds to indicate successful inclusion. |
Exclusion | There are two exclusion methods:Method 1: Exclusion from the primary controller/gateway as follows:1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual on how to set your controller into exclusion).2. Triple press the action button, the dimmer will be set to exclusion mode, and waiting to be excluded, then the dimmer will be excluded from the network.Method 2: Factory reset the dimmer will force it to be excluded from a network. (please refer to the part Factory Reset of this manual)Note: Factory reset is not recommended for exclusion, please use this procedure only if the primary controller/gateway is missing or otherwise inoperable. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | dimmer, send u0022Device Reset Locally Notification CCu0022 to associateddevices of this group to report factory reset information.2. When load state changes, send u0022Basic Report CCu0022 to associateddevices of this group.3. When a load over current is detected, send u0022Over-currentdetectedu0022 to Lifeline.4. When a mains voltage drop is detected, send u0022Voltage drop/driftu0022 to Lifeline.5. When over temperature is detected, send Emergency shutoffstatusu0022 to Lifeline. |
Enable/disable to detect load after re-power on(detect load type, minimum brightness,maximum brightness)Note: When the device does not belong to anynetwork, load detection will be enabled everytime after re-power on. When the device hasalready been added to a network, load detectionwill be disabled. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disable |
1 | enable to detect every time after re-power on |
2 | enable to detect only after first re-power on |
Wiring typeNote: this parameter is read only Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | unknown |
1 | 2 Wire With No Neutral |
2 | 3 Wire With Neutral |
Load typeNote: this parameter is read only Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | unknown |
1 | resistive |
2 | inductive |
3 | capacitive |
Enable/disable over current protection (over 1.5A for 20 seconds continuously) Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | disable |
1 | enable |
Power automatic report absolute threshold, unit is WWhen power changes above the absolutethreshold, immediately report current power value Size: 2 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 32767 | When power changes above the absolute threshold, immediately report current power value |
Power automatic report percentage threshold, unit is %When power changes above the percentage threshold, immediately report current power value Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
0 - 100 | When power changes above the percentage threshold, immediately report current power value |
Saving load state before power failure Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | shutoff load |
1 | turn on load |
2 | save load state before power failure |
Power metering automatic report time cycle, unit is second Size: 4 Byte, Default Value: 600
Setting | Description |
---|---|
5 - 2678400 | Power metering automatic report time cycle, unit is second |
Energy metering automatic report time cycle, unit is second Size: 4 Byte, Default Value: 1800
Setting | Description |
---|---|
5 - 2678400 | Energy metering automatic report time cycle, unit is second |
Voltage metering automatic report time cycle, unit is second Size: 4 Byte, Default Value: 3600
Setting | Description |
---|---|
5 - 2678400 | Voltage metering automatic report time cycle, unit is second |
Current metering automatic report time cycle, unit is second Size: 4 Byte, Default Value: 3600
Setting | Description |
---|---|
5 - 2678400 | Current metering automatic report time cycle, unit is second |
Enable/disable to send the basic report to the Lifeline when the load state changed (When value set as 1, re-power on the dimmer, it will send Basic report automatically Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable to send Basic report |
1 | Enable to send Basic report |
Default fade time (unit is second) Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Instantly |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution. |
Setting minimum brightness value Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 50 | the bigger the value is, the higher the loads minimum brightness is |
Setting maximum brightness value Size: 1 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 100 | the maximum brightness value |
Choose MOSFET driving type Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | trailing edge |
1 | leading edge |
External switch type Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Push button switch |
1 | normal on/off switch |
2 | 3-way switch |
Enable/disable external switch to be added to and removed from a network (when enables this function, triple press the external switch within 1.5 seconds to be added to or removed from a network) Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | disable |
1 | enable |
Hardware Platform | ZM5101 |
Device Type | Light Dimmer Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.06 |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-19046454 |
Z-Wave Product Id | 0x0330.0x0201.0xD00C |
Supported Notification Types | Power ManagementSystem |
Firmware Updatable | Updatable by Consumer by RF |
Supported Meter Type | Electric Energy |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |