Quickstart

This is a Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
Set your controller to add mode (see your controllers manual). Follow the instruction for Wake up. A long LED blink indicates that the add/remove was successful.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Strips, the ultra-thin multi sensor is now available in two new sensor models, Strips Drip and Strips Comfort. Drip and Comfort join Strips Guard, the thinnest magnet sensor in the world detecting if your windows are open and closed invisibly since 2015.Strip Drip sends an alarm signal if it detects a water leak. Its unique design allows it to be easily placed almost everywhere, including most places other sensors simply cant fit.With soaking pads integrated in the mounting plate even small amounts of water will be detected. The built-in temperature sensor gives the possibility to combine the leakage alarm with a freeze alarm. There is also a built-in ambient light sensor that may be useful in special applications.Strips Comfort is a very accurate temperature and ambient light sensor. The unique design and mounting plate makes it easy to place almost invisibly in your home to measure temperature or control heating, air conditioning and even windows blinds which are connected to your Z-Wave smart home system.All Strips products can be used both in-doors and out-doors and the integrated custom battery gives Strips an expected lifetime of up to 10 years. For you, this means no hassle needing to change or charge batteries in your Strips sensors for the lifetime of the products!

Reset to factory default You may need to reset Strips if your Z-Wave controller is missing or not responding.Follow the instructions for Wake up, but on the 3rd repetition, leave the magnet at the rounded edge for 10 seconds. A long LED signal indicates success.
Inclusion Set your controller to add mode (see your controllers manual). Follow the instruction for Wake up. A long LED blink indicates that the add/remove was successful.
Exclusion Set your controller to remove mode (see your controllers manual). Follow the instruction for Wake up. A long LED blink indicates that the add/remove was successful.
NIF XXXNIF
Wakeup Wake up Strips manually for Z-Wave communication. Place the magnet at the rounded edge. When the LED blinks, move the magnet away. Repeat twice within 10 seconds.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 10: High ambient light report level

3 - 64000
Size: 4 Byte, Default Value: 40000

Setting Description
3 - 64000 High ambient light report level(4 bytes)

Parameter 11: Low ambient light report level

1 - 42000(Must be significantly lower than parameter 10)
Size: 4 Byte, Default Value: 5000

Setting Description
1 - 42000 (Must be significantly lower than parameter 10)

Parameter 12: Leakage alarm

0: Off1: On
Size: 1 Byte, Default Value: 1

Setting Description
0 Off
1 On

Parameter 13: Leakage alarm level

1 to 100(1= almost dry, 100= soaking wet)
Size: 1 Byte, Default Value: 10

Setting Description
1 - 100 (1= almost dry, 100= soaking wet)

Parameter 14: Moisture reporting period

0-120: Number of hours between moisture reports
Size: 1 Byte, Default Value: 0

Setting Description
0 - 120 Number of hours between moisture reports

Parameter 2: LED alarm event reporting

0: Off1: On
Size: 1 Byte, Default Value: 1

Setting Description
0 Off
1 On

Parameter 3: Temperature & Light reporting frequency

1: Normal2: Frequent
Size: 1 Byte, Default Value: 1

Setting Description
1 Normal reporting
2 Frequent reporting

Parameter 4: Temperature reporting

0: Off1: On
Size: 1 Byte, Default Value: 1

Setting Description
0 Off
1 On

Parameter 5: Temperature reporting unit

0: Celcius1: Fahrenheit
Size: 1 Byte, Default Value: 0

Setting Description
0 Celcius
1 Fahrenheit

Parameter 6: Temperature alarms

0: Off1: On
Size: 1 Byte, Default Value: 0

Setting Description
0 Off
1 On

Parameter 7: High Temperature alarm level

-20 to + 60 (degree C)
Size: 1 Byte, Default Value: 60

Setting Description
-20 - 60 Temperature alarm level

Parameter 8: Low Temperature alarm level

-20 to + 60 (degree C)
Size: 1 Byte, Default Value: -20

Setting Description
-20 - 60 Temperature alarm level

Parameter 9: Ambient light reporting

0: Off1: On2: Report only when levels defined in parameter 10 & 11 are passed
Size: 1 Byte, Default Value: 1

Setting Description
0 Off
1 On
2 Report only when levels defined in parameter 10 & 11 are passed

Technical Data

Hardware Platform ZM5101
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 3 FW: 0.07:00.07
Z-Wave Version 6.51.10
Certification ID ZC10-19056519
Z-Wave Product Id 0x019A.0x0003.0x000A
Outdoor Use ok
Supported Notification Types Heat AlarmHome SecurityWater Alarm
Sensors Air TemperatureLuminanceMoisture
Frequency XXfrequency
Maximum transmission power XXantenna
JapanNotification Sensor