This is a
Check Z-WaveTM Controller enter inclusion mode. Pressing tamper key three times within 3 seconds to enter the inclusion mode. If the addition is successful, the LED will flash slowly.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
PSM09 is only for indoor using device. PSM09 can detect the the door is open or not. The Recessed door sensor PSM09 is Base on Z-WaveTM technology. It is the Z-WaveTM plus product, it support the security, OTA. Those newest features of the Z-WaveTM technology. Z-WaveTM is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances. Notice: if user use some command, it have to check device is security bootstrap otherwise some command cannot increment. This device is a security enabled Z-Wave Plus product that is able to use encrypted Z-Wave Plus messages to communicate to other security enabled Z-Wave Plus products. This device must be used in conjunction with a Security Enabled Z-Wave Controller in order to fully utilize all implemented functions. This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.Press the button three times in three seconds, then LED will flash for one second slowly. Press the button again and hold, the LED will light up, after about three seconds, the LED will off. Please release the button in two seconds. If the clearing is successful, the LED will flash one time per second. If it fails, the LED will flash quickly.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device. To wakeup the device please perform the following action: After the device adding to the network, it will wake-up once per day in default. When it wake-up it will broadcast the Wake Up Notificationmessage to the network, and wake-up 10 seconds for receive the setting commands.The wake-up interval minimum setting is 30 minutes, and maximum setting is 120 hours. And the interval step is 30 minutes.If the user want to wake-up the device immediately, please press the tamper key once. The device will wake-up 10 seconds.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus LifelineThis machine provides a group of groups. Each group canset 5 Nodes.Group 1: Used for event return.Report type:1. Door sensor state2.Battery state3.Reset report |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
The interval time for auto report the door/window & battery level. 0 means turn off auto report state. Units of 30 minutes. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 127 | 0 means turn off auto report state. Units of 30 minutes. |
Hardware Platform | SD3502 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 255 FW: 0.10 |
Z-Wave Version | 6.81.04 |
Certification ID | ZC10-19066570 |
Z-Wave Product Id | 0x013C.0x0002.0x006A |
Sensors | Open/Closed (Binary) |
Supported Notification Types | Access ControlHome Security |
Firmware Updatable | Updatable by Consumer by RF |
Security V2 | S2_UNAUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |