This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Aeotec Door/ Window Sensor 7 is a small window position sensor for your smart home, it monitors window and their exact opening position and lets your know when a window is tilted or completely opened. It also supports connecting external binary sensors through the dry binary contact of the Door/ Window sensor.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
2 | 5 | Control devices when magnet or external dry contacts trips |
3 | 5 | Sends our alarm message when magnet controlled or external dry sensor trips. |
4 | 5 | Sends alarm messages when tamper is tripped |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
This parameter defines if the internal magnet sensor or the external terminal input is detected and used to issue alarm notification. There is always one input active only. The other sensor input the deactivated. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Internal Magnet Sensor Used |
1 | External Terminal Inputs Used |
Off command is sent after a delay defined in this parameter. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32400 | seconds |
Time a tamper alarm is delayed. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32400 | seconds |
This parameter defines if the alarm cancellation event is reported. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Do not send Report |
1 | Send Report |
This parameter enables/disablesthe central scene function. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disabled |
1 | Enabled |
This parameter enables/disablesthe tilt function. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disabled |
1 | Enabled |
This parameter defines the polarity of the magnet sensor. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Closed when Magnet in proximity |
1 | Opened when Magnet in proximity |
This parameter defines when the red LED will indicate events. Disabling all indications may extend battery life. Size: 1 Byte, Default Value: 7
Setting | Description |
---|---|
1 | No Indications |
2 | Open/Close Status Change |
4 | Wake Up |
16 | Device Tampering |
Allows to enable the activation of a Z-Wave range test with double clicking the tamper switch. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disabled |
1 | Enabled |
his parameter defines the status of the magnet switch that causes sending a BASIC command to all devices of Association Group 2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Switch after Open and Close |
1 | Switch after Open |
2 | Switch after Close |
This parameter defines which commands is sent to 2nd Association Group Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | On |
1 | Off |
2 | On and Off |
This is the BASIC command value sent in case of On event. Size: 1 Byte, Default Value: -1
Setting | Description |
---|---|
-1 | Value |
0 - 99 | Value |
This is the BASIC command value sent in case of Off event. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-1 | Value |
0 - 99 | Value |
Off command is sent after a delay defined in this parameter. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32400 | seconds |
Hardware Platform | ZM5101 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 6.81.01 |
Certification ID | ZC10-19076677 |
Z-Wave Product Id | 0x0371.0x0102.0x0007 |
Color | White |
Supported Notification Types | Access ControlHome SecurityPower Management |
Sensors | Open/Closed (Binary) |
Firmware Updatable | Updatable by Consumer by RF |
Security V2 | S2_UNAUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |