Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

WLS-23-ZW is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. It is a Security Enabled Z-Wave Plus product and is capable of sending wireless signals to the Z-Wave enabled networkuponwaterdetection. The WaterSensingCableandbuilt-inwatersensingprobescandetect waterleakageorfloodcondition.Itcanbeplacedontheground,ormountedonthewallandfurther extended by connecting to another water sensing cable to improve detection range.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Group 1 for LifeLine: (maximum node: one) Sensor Multilevel CC (COMMAND_CLASS_SENSOR_MULTILEVEL_V4) Notification CC,V8 (COMMAND_CLASS_NOTIFICATION) Battery CC (COMMAND_CLASS_BATTERY) Device Reset Locally CC, V4 (COMMAND_CLASS_DEVICE_RESET_LOCALLY) *. Factory Reset [COMMAND_CLASS_ DEVICE_RESET_LOCALLY] [NOTIFICATION_REPORT]1. Pressand hold the function button for 10 seconds to performfactory reset and sendfactory reset report to the Control Panel. *. Battery: [COMMAND_CLASS_BATTERY] [BATTERY_REPORT] 0x64 --- 100% Battery Full 0x5A --- 90% Battery 0x50 --- 80% Battery 0x46 --- 70% Battery 0x3C --- 60% Battery 0x32 --- 50% Battery 0x28 --- 40% Battery 0x1E --- 30% Battery 0x14 --- 20% Low Battery 0xFF --- Battery Dead (Cut Off) Cut Off --- The device will stop working and the LED will flash every 4 seconds. *. Water Alarm/Restore: [COMMAND_CLASS_NOTIFICATION] [NOTIFICATION_REPORT] Water Alarm:00 00 00 FF 05 02 00 Water Restore:00 00 00 FF 05 00 01 02 *. Test Button: [WAKE_UP_NOTIFICATION] PressthefunctionbuttononcetoawakentheWaterLeakSensoranditwillsendawakeup notification along with temperature and humidity report to the Control Panel. *. Temperature/Humidity: [COMMAND_CLASS_SENSOR_MULTILEVEL][SENSOR_MULTILEVEL_REPORT] Press the function button once to send temperature and humidity information to the Control Panel. Temperature:01 42 09 D1If temperature signal 01 42 09 D1 is transmitted, 09 D1 can be viewed as 0x09D1 in Hexadecimal number. You can convert hexadecimal to decimal and divide by 100 to check the temperature data (in Celsius). 0x09D1=2513=25.13. *. Humidity:05 02 00 3B If humidity signal 05 02 00 3B is transmitted, 00 3B can be viewed as 0x003B in Hexadecimal number. You can convert hexadecimal to decimal to check the humidity level (in percentage). 003B=0x003B=59%
2 1 Group 2 for Basic Set: (maximum node: one) 1. When the Water Leak Sensor is triggered, it will send Basic set (0xFF) to the node in Group 2. 2. When the Water Leak Sensor is restored, it will send Basic set (0x00) to the node in Group 2.

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 255 FW: 4.04
Z-Wave Version 6.81.04
Certification ID ZC10-19086692
Z-Wave Product Id 0x018E.0x0003.0x0012
Supported Notification Types Water Alarm
Sensors Air TemperatureHumidity
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Notification Sensor