This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
ZDS-220 enabled product allows users to remotely control lighting, home appliance, and make home control easy with low installation and maintenance costs. You may begin with a few Z-Wave enabled devices as well as some of our products to build up a complete home automation system.The ZDS-220 is a Z-Wave enabled device and is fully compatible with any Z-Wave Plus enabled network. It can be configured as either a DIMMER or a SWITCH device. It allows remote Dimming or ON/OFF control of specified lamps. Each module is designed to act as a repeater, which will re-transmit a radio frequency (RF) signal by routing the signal around obstacles and radio dead spots to ensure that the signal is received at its intended destination.ZDS-220 is a security enabled Z-Wave plus device. A security Enabled Z-Wave Plus Controller must be used in order to fully utilize the product.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Association group_1 (max. 1 node) is default to associate with the primary controller (Gateway/Hub/Controller) for ZDS-210 Status change report, refer to below for report details:ZDS-210 will trigger AUTO report function if the Dimmer or Switch status had been changed.Device Reset Locally Notification(Only report when the ZDS-210 Dimming Switch Module has been triggered the RESET TO DEFAULT) |
2 | 4 | Dimmer mode: After receiving a dimming command from a local switch or gateway (e.g. 50%), the ZDS-220 will automatically send out a related basic set command (e.g. 50%) to its associated group. Switch mode: After receiving a basic set command from a local switch or gateway, On (0xFF) or Off (0x00), the ZDS-220 will automatically send out a related basic set command, On (0xFF) or Off (0x00) to its associated group. (Max. 4 node ID's can be assigned to this association group) |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Double Click option(set to max. brightness)0 (0x00) - Double click function disabled1 (0x01) - Double click function enabled Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Time to move the Dimmer from 0% to max. dimming values.(The ZDS-220 will implement the dimming duration if received this parameter value from controller/gateway.Otherwise,the ZDS-220 will implement the local parameter value)Dimmer Mode:From 0 to 5 secondsStep size = 1 second Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 - 5 | Seconds |
Maximum Dimmer level control Size: 1 Byte, Default Value: 99
Setting | Description |
---|---|
2 - 99 | Dimmer Level |
Minimum Dimmer level controlAC Motors:Parameter no. 18 max. = 99% Parameter no. 19 min. >= 60%Fluorescent Lamps, Fluorescent Tubes, Non-dimmable LEDs: Parameter no. 18 max. = 99% Parameter no. 19 min. = 98%Notes: 1) The maximum level must not be lower than the minimum level. 2) Parameter no. 17 MUST be set to 0] Size: 1 Byte, Default Value: 13
Setting | Description |
---|---|
1 - 98 | Dimmer Level |
Switch returns to the last position saved before power failure0 (0x00) - Switch does not save the state after power failure, device returns to u0022offu0022 position1 (0x01) - Switch saves its state before power failure Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Not save |
1 | Save |
Hardware Platform | ZM5202 |
Device Type | Light Dimmer Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 0.32 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-19086723 |
Z-Wave Product Id | 0x5254.0x8200.0x8131 |
Color | White |
Electric Load Type | Dimmable LEDFluorescentIncandescent |
Firmware Updatable | Updatable by Consumer by RF |
Security V2 | S2_UNAUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |