This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. Each module is designed to act as a repeater,which will re-transmit a radio frequency (RF) signal by routing the signal around obstacles and radio dead spots to ensure that the signal is received at its intended destination. MS10Z is a security enabled Z-Wave plus device. A security Enabled Z-Wave Plus Controller must be used in order to fully utilize the product.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline |
2 | 5 | basic set command |
Locally Button function Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Up Button ON,Down Button OFF |
1 | Up Button OFF,Down Button ON |
2 | Up Button ON/OFF,Down Button ON/OFF |
Status LED Configuration Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Output and the LED are in the different state. |
1 | Output and the LED are in the same state. |
2 | LED Always OFF |
3 | LED Always ON |
Enable Auto Turn-Off Time Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | timer disabled |
1 | timer enabled |
Auto Turn-Off Time Size: 4 Byte, Default Value: 60
Setting | Description |
---|---|
1 - 65535 | Auto Turn-Off Time |
Enable Auto Turn-ON Timer Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | timer disabled |
1 | timer enabled |
Auto Turn-ON Timer Size: 4 Byte, Default Value: 60
Setting | Description |
---|---|
1 - 65535 | Auto Turn-ON Timer |
Association Setting Parameter Size: 1 Byte, Default Value: 15
Setting | Description |
---|---|
0 | None |
1 | Local |
2 | 3-Way |
3 | 3-way&Local |
4 | Z-Wave Hub |
5 | Z-Wave hub&Local |
6 | Z-Wave hub&3-way |
7 | Z-Wave hub&Local&3-way |
8 | Timer |
9 | Timer&Local |
10 | Timer&3-way |
11 | Timer&3-way&Local |
12 | Timer&Z-Wave hub |
13 | Timer&Z-Wave hub&Local |
14 | Timer&Z-Wave hub&3-way |
15 | All |
Restores state after power failure Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | Output OFF |
1 | Output ON |
2 | The state before a power outage |
Enable or Disable local control Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | disable |
1 | enable |
Hardware Platform | ZM5202 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 6.81.03 |
Certification ID | ZC10-19086728 |
Z-Wave Product Id | 0x0312.0xFF01.0xFF03 |
Switch Type | Push Button |
Z-Wave Scene Type | Scene |
Electric Load Type | FluorescentIncandescentLED |
Color | White |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |